the gate opener
Made in Italy
E
lpro12
PLUS
GB
Flashing lamp:
19 20
230V MAX 25W
4
ON: Pre-flashing
OFF: No pre-flashing
Power supply:
OPERATING MODES
HIGH VOLTAGE ELECTRICAL CONNECTIONS
7
ON: Lamp is not operating during
Dwell time. Automatic mode.
OFF: It flashes during Dwell Time.
Automatic Mode.
POWER SUPPLY
230V 50Hz SINGLE-PHASE
21 22
DIP-SWITCH 4 and 7:
1
2
Button switch:
3
4
5
6
ST
OP
COMMON/
NEUTRAL
OPOEN
CL
OSE
Photocells and Safety Edge:
12 13
1
DIP-SWITCH 1:
ON: Photocells stop gate while opening,
reverse it once obstacle is removed
OFF: Photocells do not stop gate while
opening, reverse it in case of an
obstacle
PHOTOCELLS
AND SAFETY EDGE
24V OUTPUT (MAX. LOAD:
2 PAIRS PHOTOCELLS
1 RADIO RECEIVER)
Limit switch:
LIMIT SWIT
CH
CL
OSE
NEUTRAL
10
8
9
LIMIT SWIT
CH
OPEN
Light ON = Open gate
Light OFF = Close gate
Flashing (fast) 0.5s= Closing gate
Flashing (normally) 1s= Opening gate
Flashing (slowly) 2s= gate is stopped
24V 3W Indication Light:
3
11
Push Button Switch Pulin 3:
26
27
28
3
NEUTRAL
Led to indicate status
of Open - Stop - Close
switches
Safety Contact:
This contact must be
N.C. for the control
panel to be allowed
to work
Radio Contact:
COMMON/
NEUTRAL
CONT
ACT
RADIO
7
3
- Open/Close (Standard)
- Travel reversing on
pulsing
- Step by step
2
ON: Gate is not reversed while opening
OFF: Any pulse reverses the gate
5
ON: Step by step. Stop in between
OFF: Standard operating mode
DIP-SWITCH 2 and 5 (NEVER set BOTH of them
ON at the same time):
14 15
LOW VOLTAGE ELECTRICAL CONNECTIONS
Capacitor and Single-phase Motor:
-
+
R65
MOTOR RUN
TIME
OPEN/CLOSE
FROM 2 UP TO 128s
R64
-
+
DWELL TIME
FROM 2 UP TO 128s
29 30
18
16 17
NEUTRAL
M
Capacitor
20µF for 0.5HP
40µF for 1.0HP
Courtesy Light
230V max. 100W:
23 24
Trimmer R63
-
+
COURTESY LIGHT
FROM 2 UP TO 255s
How it works: Set the clock to the required times. On the pre-set time the gate is automatically opened and held open. Any
further pulsing (even by remote control) is not accepted by the system until the time pre-set by the clock has expired. On
expiring and after the pre-set dwell time the gate is closed automatically.
R62 trimmer on to zero, Dip-Switch 3=ON.
DIP-SWITCH No.3=ON Automatic Closing
Time clock:
3
ON= Automatic Closing
OFF= No Automatic. Semi-automatic
closing by pulse
4
3
COMMON
COMMON
OPEN
NO
-
+
Pedestrian Trimmer R62
set on to zero
Hold on switched (Deadman) control:
Pedestrian Opening:
Trimmer R62
-
+
from 3 to 30s. It can be activated
by any pulse (eg. by remote
control) superior to 2s
3
DIP-SWITCH 3
ON= Automatic Closing
OFF= No Automatic. Semi-automatic
closing by pulse
Automatic / Semiautomatic:
Automatic Operation: any pulse opens the gate, the gate
stays open as long as the Dwell time expires as set by R64
trimmer, then it closes automatically, no pulsing is required.
Semi-automatic Operation: any pulse opens the gate
that stays open. A second pulse to Close is required for
the gate to close.
Open and Close operations are achieved "by
holding a switch on" (no relay self-holding in
involved) therefore a phisical attendance is
required to keep the gate opening or closing
until either the button or key is released.
DIP-SWITCH 6
6
ON= Deadman Control. Dip-switch 4=OFF
and Dip-switch 3=OFF
OFF= Standard Operations
Dwell Time
from 2 to 128s
-
+
Trimmer R64
COMMON
OPEN
4
3
Drwg. No. 4086