background image

2

CORAL

GENERAL WARNINGS FOR PEOPLE SAFETY

THANK YOU

Thank you for purchasing a Fadini product. 

Please  read  these  instructions  carefully  before  using  this 

appliance.  The  instructions  contain  important  information 

which  will  help  you  get  the  best  out  of  the  appliance  and 

ensure safe and proper installation, use and maintenance. 

Keep this manual in a convenient place so that you can always 

refer to it for the safe and proper use of the appliance.

INTRODUCTION 

This operator is designed for a speci c scope of applications as 

indicated in this manual, including safety, control and signaling 

accessories as minimum required with Fadini equipment. 

 Any 

applications not explicitly included in this manual may cause 

operation  problems  or  damages  to  properties  and  people. 

 

Meccanica Fadini snc is not liable for damages caused by the 

incorrect use of the equipment, or for applications not included 

in this manual or for malfunctioning resulting from the use of 

materials  or  accessories  not  recommended  by  the 

manufacturer. 

 The manufacturer reserves the right to make 

changes to its products without prior notice. 

 All that is not 

explicitly  indicated  in  this  manual  is  to  be  considered  not 

allowed.

BEFORE INSTALLATION

Before commencing operator installation assess the suitability 

of  the  access,  its  general  condition  and  the  structure. 

  To 

check that the ground is stable, to avoid subsequent settling or 

deformation in the traffic control post installation area. 

□ 

Make 

sure  that  there  is  no  risk  of  impact,  crushing,  shearing, 

conveying,  cutting,  entangling  and  lifting  situations,  which 

may prejudice people safety. 

 Do not install near any source of 

heat and avoid contacts with  ammable substances. 

 Keep all 

the  accessories  able  to  turn  on  the  operator  (transmitters, 

proximity  readers,  key-switches,  etc)  out  of  the  reach  of  the 

children. 

  Transit  through  the  access  only  with  stationary 

operator. 

 Do not allow children and/or people to stand in the 

proximity  of  a  working  operator. 

  To  ensure  safety  in  the 

whole  movement  area  of  a  bollard  it  is  advisable  to  install 

photocells,  sensitive  edges,  magnetic  loops  and  detectors. 

 

Use yellow-black strips or proper signals to identify dangerous 

spots. 

  Before  cleaning  and  maintenance  operations, 

disconnect the appliance from the mains by switching off the 

master  switch. 

  If  removing  the  actuator,  do  not  cut  the 

electric wires, but disconnect them from the terminal box by 

loosening the screws inside the junction box.

INSTALLATION

All  installation  operations  must  be  performed  by  a  quali ed 

technician,  in  observance  of  the  Machinery  Directive 

2006/42/CE  and  safety  regulations  EN  12453  -  EN  12445. 

Verify the presence of a thermal-magnetic circuit breaker 0,03 

A - 230 V - 50 Hz upstream the installation. 

 Use appropriate 

objects  to  test  the  correct  functionality  of  the  safety 

accessories,  such  as  photocells,  sensitive  edges,  etc. 

□ 

  Carry 

out  a  risk  analysis  by  means  of  appropriate  instruments 

measuring the crushing and impact force of the main opening 

and closing edge in compliance with EN 12445.

 

 Identify the appropriate solution necessary to eliminate and 

reduce  such  risks. 

    In  case  where  the  gate  to  automate  is 

equipped  with  a  pedestrian  entrance,  it  is  appropriate  to 

prepare the system in such a way to prohibit the operation of 

the  engine  when  the  pedestrian  entrance  is  used. 

  Apply 

safety nameplates with CE marking on the gate warning about 

the presence of an automated installation. 

 The installer must 

inform and instruct the end user about the proper use of the 

system by releasing him a technical dossier, including: layout 

and components of the installation, risk analysis, veri cation of 

safety accessories, veri cation of impact forces and reporting 

of residual risks.

INFORMATION FOR END-USERS

The  end-user  is  required  to  read  carefully  and  to  receive 

information concerning only the operation of the installation 

so that he becomes himself responsible for the correct use of it. 

 The end-user shall establish a written maintenance contract 

with  the  installer/maintenance  technician  (on  -call). 

  Any 

maintenance operation must be done by quali ed technicians. 

 Keep these instructions carefully.

WARNINGS  FOR  THE  CORRECT  OPERATION  OF  THE 

INSTALLATION

 

For  optimum  performance  of system over  time according  to 

safety  regulations,  it  is  necessary  to  perform  proper 

maintenance  and  monitoring  of  the  entire  installation:  the 

automation,  the  electronic  equipment  and  the  cables 

connected to these. 

 The entire installation must be carried 

out by quali ed technical personnel,  lling in the Maintenance 

Manual  indicated  in  the  Safety  Regulation  Book  (to  be 

requested 

or 

downloaded 

from 

the 

site 

www.fadini.net/supporto/downloads). 

 Operator: maintenance inspection at least every 6 months, 

while  for  the  electronic  equipment  and  safety  systems  an 

inspection  at  least  once  every  month  is  required. 

  The 

manufacturer,  Meccanica  Fadini  snc,  is  not  responsible  for 

non-observance  of  good  installation  practice  and  incorrect 

maintenance of the installation.

DISPOSAL OF MATERIALS

Dispose  properly  of  the  packaging  materials  such  as 

cardboard,  nylon,  polystyrene  etc.  through  specializing 

companies (after veri cation of the regulations in force at the 

place of installation in the  eld of waste disposal). Disposal of 

electrical  and  electronic  materials:  to  remove  and  dispose 

through specializing companies, as per Directive 2012/19/UE. 

Disposal  of  substances  hazardous  for  the  environment  is 

prohibited.

Meccanica Fadini s.n.c.

Director in charge

CE DECLARATION OF CONFORMITY of the manufacturer:

Meccanica Fadini snc (Via Mantova, 177/A - 37053 Cerea - VR - Italy) declares under own responsibility that: 

Coral

 complies 

with the 2006/42/CE Machinery Directive, and also that it is sold to be installed in an “automatic system”, along with original 

accessories  and  components  as  indicated  by  the  manufacturing  company.  An  automatic  gate  operator  is,  by  law,  a 

“machinery” and therefore the installer must  t the equipment with all of the applicable safety norms. The installer is also 

required to issue the installer’s Declaration of Conformity. The manufacturer is not liable for possible incorrect use of the 

product. The product complies with the following speci c norms: analysis of the risks and subsequent action to cure them 

as per EN 12445 and EN 12453,  Low Voltage Directive 2014/35/UE, Electromagnetic Compatibility 2014/30/UE. In order to 

certify the product, the manufacturer declares under own responsibility the compliance with the EN 13241-1 PRODUCT 

NORMS.

fully retractable oil-hydraulic bollard

Summary of Contents for CORAL 1050

Page 1: ...EN 13241 EN 12453 EN 12445 CORAL 1050 1063 1080 Instructions manual pages 1 16 the gate opener FULLY RETRACTABLE OIL HYDRAULIC BOLLARDS POST DIAMETER 100 mm HALL MAGNETIC LIMIT SWITCH GB...

Page 2: ...ith a pedestrian entrance it is appropriate to prepare the system in such a way to prohibit the operation of the engine when the pedestrian entrance is used Apply safety nameplates with CE marking on...

Page 3: ...erator can be introduced ready for operation as soon as the wiring has been completed As soon as the retractable post receives a command from a key switch or radio transmitter it rises from its interr...

Page 4: ...tail of retractable post with hoisting connection PRELIMINARY OPENING OF ALL FUNCTIONAL COMPONENTS Start by removing the cover plate to reveal the operator and separate the individual components with...

Page 5: ...res use electric cables with sections suited to the installation Pic 3 230V 50 Hz 1 2 3 4 5 6 6 7 2x1 mm 2x1 mm 3x1 mm 4x1 mm 4x1 mm 4x1 mm 8 10 11 8 9 1 Led ashing light with built in aerial 2 Stand...

Page 6: ...Pic 4 Pic 5 IMPORTANT once the housing has been positioned and installation completed it is important for the top edge to be level with the ground Piping 5 cm for passage of electric wires Concrete c...

Page 7: ...r inside the housing Pic 6 IMPORTANT PASS THE MOTOR LIMIT SWITCH SOLENOID VALVE AND LED POWER SUPPLY ELECTRIC WIRES THROUGH THE PIPING WITHOUT TEARING OR CUTTING THE CABLES Hoisting hook Oil hydraulic...

Page 8: ...near the installation to prevent interference or any a ecting action with the magnetic loops of the vehicle detecting device if installed or with any other electronic equipment included in the system...

Page 9: ...are properly alight the post should move up on the rst commanding pulse should it fail disconnect power supply and swap the connections to the live terminals NOTE WELL supply the system with electric...

Page 10: ...GROUND LEVEL CLOSURE COVER PLATE Use the four screws to close the cover plate Lift the retractable post for facilitate closure of the post cover with the bu er give the command by encoding a transmit...

Page 11: ...ds IP 67 A 40 C with speci c optional accessories Ref General Catalogue PERFORMANCE CORAL 1050 Frequency of use intensive Service cycle rise 4 7 s dwell 30 s lower 4 4 s dwell 30 s Complete cycle time...

Page 12: ...lard to avoid that settling at a later stage causes problems to the system 5 Make sure the site is free from utilities that may interfere with it 6 Make sure that electromagnetic sources are at a suit...

Page 13: ...CORAL 13 fully retractable oil hydraulic bollard...

Page 14: ...14 CORAL fully retractable oil hydraulic bollard...

Page 15: ...antity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services including installation maintenance repairs and replacements to be made only by us...

Page 16: ...extra capacitor to the existing one instructions manual is to be referred to Check the correct functioning of the signal LED lights if incorporated in the bollard head Sight check the electronic board...

Reviews: