All the electrical connections to the control panel are to be made as per – Drawing 1795 – Elpro 6 exp having the following features:
terminals for the keyswitch open-stop-close, photocells, safety edge, courtesy light, remote control to terminals 3 & 4 where the first
pulse opens the door, the second stops it and the third re-cycles to open or close.

ELECTRICAL WIRING DIAGRAM OF THE OIL-HYDRAULIC GARAGE DOOR OPERATOR
APROLI 480 TO THE ELECTRONIC CONTROL PANEL

6

 

exp

ALL OPERATIONS

OPEN, STOP & CLOSE

RADIO CONTACT

3

4

BIRIO A8 AERIAL

LED ON VOLTAGE

SUPPLIED

TRANSFORMER

230

0

02

4

meth

8V
A

RADIO CONTROL
PLUG-IN CARD SUPPORT

24 V OUTPUT

1

°

 CHANNEL

ASTRO 43/2 RADIO RECEIVER
PLUG-IN  PC BOARD

MOTOR RUN

OPEN & CLOSE TIME

DWELL TIME

1

2

ON

OFF

Should more pairs of photocells be required than the

recommended quantity, fit an auxiliary transformer outside

the control box.

NOTE WELL: THIS PANEL IS TESTED TO OPERATE GATES

ONLY THROUGH FADINI ACCESSORIES. NO GUARANTEE

FOR ACCESSORIES OF OTHER MAKE OR SPECIAL

APPLICATIONS.

- COURTESY LIGHT FOR TWO MINUTES. ON - FLASHING LAMP. OFF

- AUTOMATIC RE-CLOSING. ON - SEMI-AUTOMATIC.OFF

DIP-SWITCH

CAPACITOR

12,5 

µ

F

FUSE

630 mA

FUSES

5 A

230 V SINGLE-PHASE

SUPPLY VOLTAGE

230 V - 25 W 

MAX.

COURTESY LIGHT

SINGLE-PHASE MAX. 400W

ELECTRIC MOTOR

EARTH

MAX. PERMITTED

LOAD:

1 PAIR PHOTOCELLS

1 RADIO RECEIVER

24 V OUTPUT A.C.

LIMIT SWITCH. OPEN. N.C.

LIMIT SWITCH. COMMON

LIMIT SWITCH. CLOSE. N.C.

N.O. CONTACT. OPEN SWITCH

STOP CLOSE AND RADIO

N.C. CONTACT. PHOTOCELLS

AND SAFETY EDGE

BUTTON ON

THE COVER LID

IT IS ILLUMINATED WHEN

VOLTAGE IS SUPPLIED

KEYSWITCH
PRIT 19

STOP

OPEN

CLOSE

COMMON

ELECTRICAL CONNECTIONS
KEYSWITCH PRIT 19

PC BOARD DRWG. 1795

230 VOLTS
MAINS SUPPLY

1

2

3

4

5

6

7

8

9

10

11

12

13

14

GARAGE DOOR OPERATOR COMPLETE WITH ALL THE RECOMMENDED ACCESSORIES
FOR A GOOD PERFORMANCE

1 - 0.03 Amp. CIRCUIT BREAKER

2 - MIRI 4  FLASHING LIGHT 25 Watts

FITTED WITH BIRIO A8 AERIAL

3 - PLUG-IN RADIO RECEIVER CARD ASTRO 43 SAW

4 - ELECTRONIC CONTROL BOX Elpro 6 exp

5 - START PUSH BUTTON

6 - KEYSWITCH PRIT 19

7 - SAFETY EDGE. LOW PROFILE

8 - PHOTOCELL TRIFO 11. RECEIVER

9 - 25 Watt LAMP

10 - OPERATOR APROLI 480

11 - COVER TO PROTECT THE VALVES

12 - FIXING BRACKET

13 - PHOTOCELL TRIFO 11. PROJECTOR

14 - RADIO TRANSMITTER ASTRO 43 TWO BUTTONS

PLUG-IN

ASTRO 43

1 2 3 4 5 6 7 8 9

10 11 12 13 14 15 16 17 18

M1

COMUNE

230 V - 25 W 

MAX.

FLASHING LAMP

R1

R2

1

2

3

4

5

6

7

8

9

1

0

N . C.

C

N .A.

G

N

D

AN

T.

I. T.F

.

AS

TR

O 4

3

INN

ES

TO

R2

R1

open

12

3

4

PIC. 17

PIC. 16

10

11

open

Summary of Contents for Aproli 480

Page 1: ...10 2005 INSTALLATION MANUAL GB...

Page 2: ......

Page 3: ...RM COUNTERWEIGHT COUNTERWEIGHT CASE BOTTOM DOOR WHEEL 100x5 mm REINFORCEMENT PLATE TO BE FIXED TO THE DOOR FRAME DOOR HANDLE DOOR UPPER EDGE GARAGE DOOR LATERAL SUPPORT WEATHER STRIP WITH COVER APROLI...

Page 4: ......

Page 5: ...ARM PIVOT FIXING ON TO THE GUIDE ARM OPERATOR IN THE OPEN POSITION TELESCOPIC ARM OVERLAPPING THE DOOR ARM WHEN THERE IS NO SPACE BETWEEN ARM AND COUNTERWEIGHT 10 5 FIXING ON TO THE GUIDE ARM Rotate...

Page 6: ......

Page 7: ...dd counterweight to improve running smoothness and balance if required MAXIMUM PRESSURE VALVE CLOSE GREEN COLOUR LESS POWER MORE POWER S B RELEASE LEVER TURN IT ANTI CLOCKWISE AIR BLEED The two safety...

Page 8: ......

Page 9: ...ar It is recommended that the cable is allowed to dangle free by 130 cm so that the door can go fully up to the end of the permitted stroke It is essential to make sure that the shaft rotates in the r...

Page 10: ......

Page 11: ...PLUG IN RADIO RECEIVER CARD ASTRO 43 SAW 4 ELECTRONIC CONTROL BOX Elpro 6 exp 5 START PUSH BUTTON 6 KEYSWITCH PRIT 19 7 SAFETY EDGE LOW PROFILE 8 PHOTOCELL TRIFO 11 RECEIVER 9 25 Watt LAMP 10 OPERATOR...

Page 12: ......

Page 13: ...ed before the shaft ie the torsion fulcrum must coincide with the centre line of the door right in the middle between upper and lower guide rollers See Pic 20 Please note once Aproli 480 has been fixe...

Page 14: ......

Page 15: ...30 W Absorbed current 1 8 A Capacitor 12 5 F Motor revolution 1 350 r p m IP Protection Standard IP 55 Motor rated torque 1 3 Nm Lamp 230 V 25 W Intermittent service S 3 TECHNICAL SPECIFICATIONS APROL...

Page 16: ......

Reviews: