FACTO LILY User Manual Download Page 7

Page 7 

 

 

WARNING 

 

l

 

Risk  of  electric  shock  -  This  pump  is  supplied  with  a  grounding 
conductor  and  grounding  type  attachment  plug.  To  reduce  risk  of 
electric  shock,  be  certain  that  it  is  connected  only  to  properly 
grounded, grounding-type receptacle. 

l

 

To  reduce  the  risk  of  electrical  shock,  use  only  on  portable 
self-contained fountains no larger than 5 feet in any dimension.   

l

 

Risk of electric shock - do not remove cord and strain relief. Do not 
connect conduit to pump. 

l

 

This pump has been evaluated for use with water only. 

l

 

Risk  of  electric  shock 

  this  pump  has  not  been  tested  for  use  in 

swimming pool or marine areas. 

l

 

Do not connect to any voltage other than that shown on the pump. 

l

 

Always disconnect pump from electrical outlet before handling it or 
moving it. 

l

 

Don

t operate without water. 

l

 

Operate pump completely submerged for proper cooling.

 

 
 
 

PERFORMANCE                                                                                                                                           
 

A clogged or dirty intake screen will greatly reduce performance. 
If the pump is used on a dirty surface, raise it slightly to reduce the amount of debris contacting the intake. 
If less flow is desired, adjust the flow control lever on the side of the pump or restrict the discharge flow. 
 
Do  not  let  the  pump  run  when  not  submerged  in  water.  Doing  so  may  damage  the  pump.  Always 
submerge  the  pump  first,  and  then  plug  in  the  electrical  outlet.  The  pump  might  run  dry  the  first  few 
minutes because there is air in the pump and the tube. This is normal. Please unplug and re-plug pump 
several times, it will work properly after a few minutes.   
 
The  pump  is  to  be  supplied  through  a  residual  current  device  (RCD)  with  a  rated  residual  operating 
current not exceeding 30 mA.   

 
 

MAINTENANCE                                                                                                                                                 
 

To clean the pump, remove the back cover and the impeller. 
 
Use a small brush or stream of water to remove any debris. 
 
CAUTION: The pump shaft cannot be removed.   
IF THE PUMP FAILS TO OPERATE, CHECK THE FOLLOWING: 

l

 

Check the circuit breaker and try another outlet to make sure the pump is getting electrical power. 
NOTE:  Always  disconnect  pump  from  electrical  outlet  before  handling  it  or  moving  it  to  another 
location. 

l

 

Check the pump discharge and tubing for kinks and obstructions. Algae build up can be flushed out 
with a garden hose. 

l

 

Check the inlet to ensure it is not clogged with debris. 

l

 

Remove  the  pump  inlet  to  access  the  impeller  area.  Turn  the  rotor  to  ensure  it  is  not  broken  or 
jammed. 

l

 

Monthly maintenance will increase your pump

s life.   

NOTE: Ensure that the electrical cord loops below the electrical outlet to form a 

drip loop

. This will 

prevent water from running down the cord into the electrical outlet. 

 
 

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn

Summary of Contents for LILY

Page 1: ...Page 1 Model Mod le 83035008 LILY FOUNTAIN User s manual p 2 FONTAINE LYS Guide de l utilisateur p 7 PDF pdfFactory Pro www fineprint cn...

Page 2: ...sent Compare parts with package contents list and diagram above If any part is missing or damaged do not attempt to assemble the product or return to the place of purchase Contact our customer service...

Page 3: ...into the water accidentally turn off the circuit breaker immediately 7 If any leakage occurs around the pump housing turn off the circuit breaker immediately and have the pump serviced by a registered...

Page 4: ...an the fountain water basin the pump s outlet nozzle and PVC plastic tube for dirt and debris with a damp cloth if necessary 19 If the fountain is not going to be used for a long period time unplug an...

Page 5: ...hat may have been trapped Reverse the steps in the assembly instructions to replace the pump B Be careful not to spill water onto the plug of the pump DO NOT allow the pump to run dry TROUBLESHOOTING...

Page 6: ...vice 1 866 206 0888 Part Description Model no Ratings Quantity B Pump WP 350 AC 120V 0 070A 60Hz 1 SUBMERSIBLE PUMP INSTRUCTIONS SUBMERSIBLE PUMP OWNER S MANUAL INTRODUCTION This pump has been careful...

Page 7: ...water Doing so may damage the pump Always submerge the pump first and then plug in the electrical outlet The pump might run dry the first few minutes because there is air in the pump and the tube Thi...

Page 8: ...free service line at 1 866 206 0888 from 8 AM to 6 PM Monday to Friday Eastern time RONA reserves the right to repair or replace the defective product at its discretion The product is guaranteed for...

Page 9: ...liste du contenu de l emballage et le sch ma ci dessus Si une pi ce est manquante ou endommag e n essayez pas d assembler le produit ou de le retourner au magasin o vous l avez achet Appelez le Servi...

Page 10: ...e la pompe 4 Utilisez la source d alimentation lectrique appropri e indiqu e sur la fiche signal tique de la pompe 5 Assurez vous que la prise lectrique utilis e pour la pompe est quip d un disjoncteu...

Page 11: ...ur laquelle elle est con ue 17 Cette fontaine n est pas con ue pour une utilisation commerciale 18 Changez r guli rement l eau de la fontaine Nettoyez le bassin d eau de la fontaine l embout de sortie...

Page 12: ...nstructions d assemblage pour remplacer la pompe B Attention ne pas renverser d eau sur la prise de la pompe NE laissez PAS la pompe fonctionner sec GUIDE DE D PANNAGE 2 Si la POMPE de votre fontaine...

Page 13: ...lient le 1 866 206 0888 Pi ce Description No de mod le Alimentation Quantit B Pompe WP 350 CA 120V 0 070A 60Hz 1 INSTRUCTIONS POMPE SUBMERSIBLE POMPE SUBMERSIBLE MANUEL DE L UTILISATEUR INTRODUCTION C...

Page 14: ...en contact avec l admission Si un d bit r duit est d sir r glez le r gulateur sur le couvercle d tanch it pour r duire le d bit Ne laissez pas la pompe fonctionner lorsqu elle n est pas submerg e Cec...

Page 15: ...de votre produit FACTO bris pi ces manquantes etc veuillez appeler notre ligne de service pour parler un technicien au 1 866 206 0888 du lundi au vendredi de 8h 18 h heure normale de l Est RONA se r...

Reviews: