Faber Vejen Installation Manual Download Page 16

I n s t a l l a t i o n   m a n u a l

1 6

Symbol

Unit

 Reference gas/inlet pressure

G20-20

G30-30

G31-37

mbar

Emissions in space heating

NOx

102

123

128

mg/kWh

input   

(GVC)

Direct heating output

Nominal heat output

P

nom

5,8

5,8

5,8

kW

Minimum heat output (indicative)

P

min

2,8

2,8

2,8

kW

Useful efficiency (NCV)

At nominal heat output

th,nom

91,2

91,2

91,2

%

At minimum heat output (indicative)

th,min

87,3

87,3

87,3

%

Appliance input data

Input

Hi

6,4

6,4

6,4

kW

0,689

0,203

0,258

m³/h

0

0,484524

kg/h

Burner pressure at full mark

16,6

29,1

35,8

mbar

Power requirement for permanent pilot light

Additional electricity consumption 

At nominal heat output

el

max

0

0

0

kW

At minimum heat output

el

min

0

0

0

kW

In standby mode

el

SB

0

0

0

kW

Energy-efficiency

Energy-efficiency class

B

B

B

Energy-efficiency index 

EEI

82

82

82

Type heating output/control room temperature

yes

no

no

no

no

no

Glen Dimplex Benelux  Saturnus 8 Heerenveen The Netherlands 

With mechanical control of the room temperature by thermostat

Control of room temperature, with open 

window detection

no

With electronic control of the room temperature

With electronic control of the room temperature plus day-time 

switch

With optional remote control

no

With electronic control of the room temperature plus week-time 

switch

0

0

kW

Other control options

One step heat output, no control of room temperature

Control of room temperature, with 

presence detection

no

Two or more manually adjustable stages, no control of room 

temperature

0

Gas rate at full mark

Power requirement for permanent pilot light            (if 

applicable)

P

pilot

Gas connection

3/8"

Indirect heating functionality

no

Category

II2H3+, II2H3P

Diameter outlet/inlet

100/150

Technical data

Type indication(s)

Vejen

Type appliance

C11/C31/C91

14  Technical data

Summary of Contents for Vejen

Page 1: ...Installation manual Vejen 40011673 1904 Vejen ENG...

Page 2: ...I n s t a l l a t i o n m a n u a l 2 1 0 2 0...

Page 3: ...I n s t a l l a t i o n m a n u a l 3 3 0 4 0 4 1...

Page 4: ...I n s t a l l a t i o n m a n u a l 4 4 2 4 3 5 0 5 1...

Page 5: ...I n s t a l l a t i o n m a n u a l 5 5 2 5 3 6 0a 6 0b...

Page 6: ...I n s t a l l a t i o n m a n u a l 6 7 0 8 0...

Page 7: ...I n s t a l l a t i o n m a n u a l 7 9 0 10 0b 10 0d 10 0a 10 0c 10 0e...

Page 8: ...every year and maintained in accordance with these instructions and the applicable national and local regulations Ensure that the data on the type label matches the local gas type and pressure The se...

Page 9: ...former D LED Symbio module E Slider 4 3 Preparing the fire Remove the fire from its packaging Open the operation door see fig 3 0 take the packaged parts from the fire and remove the bolts in the bott...

Page 10: ...suring the burner pressure Check the burner pressure only with proper primary pressure Turn measuring nipple B see fig 8 0 some few turns open and connect a measuring hose to the gas regulator The pre...

Page 11: ...R fig 12 1 and 12 2 Length horizontal plane The horizontal length consists of the elements H J L M P and R fig 12 1 and 12 2 Elbows 90 in the horizontal plane Horizontal bends are bends which are enti...

Page 12: ...x x x 12 65 10 60 50 40 30 0 0 x x x x 13 65 10 60 50 40 30 0 0 x x x x 14 65 10 60 50 40 30 0 0 x x x x 15 65 10 60 50 40 30 0 0 x x x x 16 65 10 60 50 40 30 0 0 x x x x 17 65 10 60 50 40 30 0 0 x x...

Page 13: ...I n s t a l l a t i o n m a n u a l 1 3 Fig 12 1 Fig 12 2 fig 12 1 fig 12 2 fig 12 3 Fig 12 3 12 Examples flue materials...

Page 14: ...d in horizontal direction x 1 flue pipes at an angle in meters x 0 7 meter Value Starter length STL First part on top of the appliance Flue length from 0 1m till 0 45m Flue length from 0 5m till 0 90m...

Page 15: ...re first an adjuster to 130 200 and 1 meter 130 200 after that reduce to 100 150 and everything 100 150 0 5 Restrictor size Value for the comma Extra information Value behind the comma Search in the t...

Page 16: ...fficiency index EEI 82 82 82 Type heating output control room temperature yes no no no no no Glen Dimplex Benelux Saturnus 8 Heerenveen The Netherlands With mechanical control of the room temperature...

Page 17: ...Two gable outlets against over each other 1000 L Distance between two roof outlets 450 M Two roof outlets above each other on a pitched roof 1000 N Two gable outlets next to each other 1000 Short roo...

Page 18: ...I n s t a l l a t i o n m a n u a l 1 8 16 Dimensional drawings 16 1 Vejen...

Page 19: ...I n s t a l l a t i o n m a n u a l 1 9 16 2 Position gas connection...

Page 20: ...2 0 Dealerinfo www faber fires eu info faber fires eu Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen...

Reviews: