I n s t a l l a t i o n m a n u a l
1 0
6 Placing the decoration material
It is not permitted to use other or to add more material in the
combustion chamber.
Keep the pilot light always free of decoration material!
•
Place the glass plate on the bottom in the recesses on the
left and right. See fig. 6.0a and b.
•
Spread the glass fragments over the glass panel (one layer)
and cover these with the supplied vermiculite grains.
(The amount of vermiculite affects the intensity of the glow
effect and can be done according to your own discretion).
•
Place the imitation logs. Make sure that the logs are properly
connected to the tube burners and rest on the bottom of the
fire.
If necessary remove glass fragments and/or vermiculite
underneath the burners. (See the supplied log set instruction
card).
•
Spread the rest of the vermiculite and the chips over the
bottom of the burning chamber. Ensure that the air openings
are not covered.
Start the fire as described in the user manual. Check the appearan-
ce of the flames and for burning against the vermiculite grains.
7 Checking the installation
7.1
Checking the ignition of pilot light and
main burner
Light the fire as described in the user manual.
•
Check that the pilot flame is not covered by chips and/or an
imitation log.
•
Check the ignition of the main burner on full and low setting.
(ignition must be smooth and quiet).
7.2
Checking for gas leaks
Check with a gas leak finder or spray all connections and pipes for
gas leakage.
7.3
Checking the burner pressure and
primary pressure
Check that the burner pressure and primary pressure match with
the information listed in the manual. See Chapter 14.
Measuring the primary pressure:
•
Close the shut-off valve.
•
Turn measuring nipple A (see fig. 8.0) some few turns open
and connect a measuring hose to the gas regulator.
•
Take this measurement at highest setting of the fire and when
the fire is set to pilot light.
Do not connect the unit if the pressure is too high.
Measuring the burner pressure:
Check the burner pressure only with proper primary pressure!
•
Turn measuring nipple B (see fig. 8.0) some few turns open
and connect a measuring hose to the gas regulator.
•
The pressure must correspond to the value indicated in the
technical specifications of this manual. In case of deviation
contact the manufacturer.
>
Please note:
Close all pressure measuring nipples and check for gas leakage.
7.4
Checking the flame image
Let the fire burn for at least 20 minutes at highest setting and check
the flame for:
•
Flame distribution
•
Color of the flames
If one or both points are not acceptable then check:
•
The log set layout and/or the amount of glass granulate/chips
on the bottom plate.
•
The pipe connections for leaks (in case of blue flames).
•
Whether the correct flue restrictor is fitted. See fig. 9.0.
• The outlet.
o
Wall terminal right side up
o
Roof terminal on the right position
o
If the maximum horizontal flue lengths is not exceeded.
8 Instructions for the client
•
Recommend that the unit should be checked annually by a
qualified specialist to ensure the safe use and to guarantee a
long service life.
•
Give advice and instructions on care and cleaning of the
glass. Highlight the danger of burnt-in fingerprints.
•
Instruct the customer on the operation of the appliance.
•
Hand over to customer:
o
Installation manual
o
User manual
o
Log set instruction card
9 Annual maintenance
9.1
Checking and cleaning
•
Check and clean if necessary after verification:
o
the pilot light
o
the combustion chamber
o
the glass
o
the logs for breakage
o
the outlet
o
the wiring/contacts for corrosion
•
Replace, if necessary:
o chips/vermiculite
o
Glass granulate
9.2
Cleaning the glass
Most deposits can be removed with a dry cloth. Clean the glass
with Faber glass polish..
> Please note:
Avoid fingerprints on the glass. These are no longer removable
after they are burnt in!
Now carry out check-up as described in Chapter 7.
10 Conversion to other gas type
Conversion to another type of gas can only be carried out by a
qualified installer / dealer.
To do so, please contact your dealer.
Specify with your order always the type and serial number of the
device.
Summary of Contents for Vejen
Page 1: ...Installation manual Vejen 40011673 1904 Vejen ENG...
Page 2: ...I n s t a l l a t i o n m a n u a l 2 1 0 2 0...
Page 3: ...I n s t a l l a t i o n m a n u a l 3 3 0 4 0 4 1...
Page 4: ...I n s t a l l a t i o n m a n u a l 4 4 2 4 3 5 0 5 1...
Page 5: ...I n s t a l l a t i o n m a n u a l 5 5 2 5 3 6 0a 6 0b...
Page 6: ...I n s t a l l a t i o n m a n u a l 6 7 0 8 0...
Page 7: ...I n s t a l l a t i o n m a n u a l 7 9 0 10 0b 10 0d 10 0a 10 0c 10 0e...
Page 18: ...I n s t a l l a t i o n m a n u a l 1 8 16 Dimensional drawings 16 1 Vejen...
Page 19: ...I n s t a l l a t i o n m a n u a l 1 9 16 2 Position gas connection...