Faber TheTUBE Installation And User Manual Download Page 6

                                                                                                                                              

5 < 

<

 

<

 

<

 

 

5.3

 

Extinguishing the pilot light. 

 

Turn the knob to the OFF position, 
and the pilot light will be 
extinguished. 

 

Turn off the tap on the gas bottle. 

 

6

 

Checking  

6.1

 

Checking the ignition of the pilot 

burner, main burner. 

 

Ignite the pilot burner as described in 
chapter 5  

 

Check the ignition of the main burner 
at full mark and low mark (the 
ignition should proceed smoothly). 

6.2

 

Checking for gas leakage.  

Check all connections and attachments for 
possible gas leaks. 
This can be done with the help of: 

 

a small brush with washing-up liquid 
and water 

 

a gas leak spray  

 

a gas leak detector. 

Dry off the checked connections after the 
check-up. 
 

7

 

Instruction client 

 

Recommend that the appliance be 
serviced annually by a Gas Safe 
registered gas fitter in order to 
guarantee a safe use and a long 
lifespan. 

 

Point out the lifespan of the gas hose 
and the pressure regulator to the 
client. 

 

Advise and instruct the client about 
maintenance and cleaning of the 

glass. Emphasize the risk of burning in 
fingerprints. 

 

Instruct the client about the 
operation of the appliance.  

 

Hand over to the client: 

 

 Installation guide 

 

8

 

Annual  maintenance 

8.1

 

Checking:   

Check and clean if necessary after check-up: 
The main burner, especially for the primary 
air intake (see fig.1.5 )  
The pilot light, especially for the primary air 
intake (see fig.1.6 ) 
The glass 
The log set for possible fractures 
Gas hose and pressure regulator. 

 

8.2

 

Cleaning the glass 

Most deposits can be removed by means of a 
dry cloth. You can use ceramic hob cleaner to 
clean the glass. 
Note: prevent fingerprints on the glass. These 
will be burned into it once the appliance is 
used and cannot be removed. 
 
Now carry-out the check-up as described in 
chapter 6 “Checking”. 
 
 

9

 

Conversion to a different type of 
gas.  (e.g. natural gas) 

This can only be done by replacing the correct 
burner unit. Please get in touch with your 
supplier for this. 
Always mention the type and serial number of 
the appliance when giving the order. 

  

 

Summary of Contents for TheTUBE

Page 1: ...TheTUBE 40011149 1820 Installation and users guide ENG ENG ...

Page 2: ...1 L 1 1 A 1 1 B 1 1 C 1 2 A 1 2 B 1 2 C ...

Page 3: ...2 L 1 3 1 5 1 6 1 7 A ...

Page 4: ...be cool down before placing the cover If The Tube is not in use for a considerable period of time we advise you to store it inside Note damage to the lacquer will result in corrosion 2 1 Tips for the safe use of gas bottles Gas bottles should always be in an upright position both while they are in use and during transportation Never take a flame or a burning object near a gas bottle during the ins...

Page 5: ... Tube from moving and prevent damage to the flexible hosing for assembling you can use the holes in the bottom plate Disconnect The Tube if you plan to move The Tube 4 3 Removing glass Remove the top plate of the Tube and on screw the mounting bracket and remove the four glass clips away the glass can now be removed Fig 1 2 A 1 2 B en 1 2 C Replacing the glass is done in reverse order Remove all F...

Page 6: ...lient Advise and instruct the client about maintenance and cleaning of the glass Emphasize the risk of burning in fingerprints Instruct the client about the operation of the appliance Hand over to the client Installation guide 8 Annual maintenance 8 1 Checking Check and clean if necessary after check up The main burner especially for the primary air intake see fig 1 5 The pilot light especially fo...

Page 7: ... Input Nett kW 6 5 6 5 inlet pressure mbar 37 20 Gas rate at 15ºC and 1013 mbar l h 249 698 Gas rate at 15ºC and 1013 mbar gr h 470 Burner pressure at full mark mbar 34 7 8 5 Injector main burner 1 3 2 1 Pilot assembly LPG9720 NG 9709 Gas control valve Seagas B13 Seagas B13 Gas connection ...

Page 8: ...7 L 11 Dimensions ...

Page 9: ...8 L ...

Page 10: ...9 L ...

Page 11: ...10 L ...

Page 12: ......