Installation manual Relaxed M,L Smart
9 <
<
<
<
Ventilation
Correct ventilation prevents damaging overheating
of the gas control block and its electronics and also
limits the temperature of the convection air. Use
the (optional) supplied Faber ventilation grids
(article number A9296400) or a similar alternative
with a minimum free passage of 200cm² per grid,
in the space above the fire, when building the false
chimney. Within the false chimney, an horizontal
screen plate, made of non-combustible material,
must be installed just above the ventilation
openings. (see fig. 1.0-A).
Installation and finishing
Please note!
Take into account a minimum distance of
2mm due to expansion of the fireplace.
Take into account the thickness of any
finishing layer!
Construct the false chimney against the build-in
frame, see fig. 1.0-B).
5
Removing glass
Remove the vertical cover strips (see fig.
2.1-A).
Remove the horizontal cover strip (see fig.
2.2-B).
Place the suction cups on the glass (see
fig. 2.0).
Remove the sealing cord (see fig. 2.3).
Remove the vertical strips (see fig. 2.2-C).
Carefully lift the glass and pull the
underside towards you (see fig. 2.4).
For replacing the glass repeat the steps in reverse
order.
Please note!
Avoid fingerprints on the glass, these are no
longer removable once the fire is used.
6
Placing decoration material
Please note!
It is not permitted to use other or to add
more material in the combustion
chamber.
Do not throw the decoration material on
the burner at once. It is possible that the
burner gets clogged.
See the supplied decoration instruction card or
chapter 18.1 or 18.2:
Place part of the ash material at the
burner and the cover plate.
Place the log set.
Divide the rest of the ash material at the
burner and the cover plate.
Please note!
Keep the pilot flame free from ash material.
Start the fireplace as described in the user
manual.
Assess whether the flame distribution is
good. Move or remove any ash material
to create a nice glow bed.
Install the front glass and check the fire
image.
7
Checking the installation
Checking for gas leaks
Check with a gas leak finder all connections and
pipes for gas leakage.
Check primary- and burner pressure
Check if the primary pressure correspond to the
data on the rating plate.
Measuring the primary pressure:
Close the shutoff valve. Turn the
measuring nipple “A” (fig. 1.4) a few turns
to open and connect a measuring hose to
the gas valve.
Take this measurement when the
fireplace runs at high and low settings.
Do not use the device if the pressure
deviates (+20% or -20%).
Measuring the burner pressure:
Check the burner pressure only with proper
primary pressure.
Turn measuring nipple “B” (see fig. 1.4)
some turns open and connect a measuring
hose to the gas valve.
The pressure must correspond to the
value indicated in the technical
specifications of this manual. In case of
deviation contact the manufacturer.
Please note!
Close both pressure measuring nipples and
check for gas leakage.
Check ignition and burner
Ignite the fireplace by using the remote control as
described in the user manual and test all burner
possibilities.
Summary of Contents for Relaxed M Smart
Page 1: ...Installation manual Relaxed M Smart Relaxed L Smart ENG 40010635 2010...
Page 2: ...Installation manual Relaxed M L Smart 1...
Page 3: ...Installation manual Relaxed M L Smart 2...
Page 4: ...Installation manual Relaxed M L Smart 3 1 1 1 2 1 3 1 4 1 5 1 6...
Page 5: ...Installation manual Relaxed M L Smart 4 1 7 2 0 2 1 2 2 2 3 2 4 2 5 A C B 1 2...
Page 6: ...Installation manual Relaxed M L Smart 5...
Page 15: ...Installation manual Relaxed M L Smart 14 12 Examples flue materials...
Page 21: ...Installation manual Relaxed M L Smart 20 16 Troubleshooting guide...
Page 22: ...Installation manual Relaxed M L Smart 21...
Page 23: ...Installation manual Relaxed M L Smart 22 17 Dimensional drawings 17 1 Relaxed M Smart...
Page 24: ...Installation manual Relaxed M L Smart 23 17 2 Relaxed L Smart...
Page 25: ...Installation manual Relaxed M L Smart 24 17 3 Remote access door A9299463...
Page 26: ...Installation manual Relaxed M L Smart 25 17 4 Ventilation grid article number A9296400...
Page 28: ...Installation manual Relaxed M L Smart 27 18 2 Log set Relaxed L Smart...