![Faber Relaxed L Smart Installation Manual Download Page 11](http://html.mh-extra.com/html/faber/relaxed-l-smart/relaxed-l-smart_installation-manual_535941011.webp)
Installation manual Relaxed M,L Smart
10 <
<
<
<
7.1
Checking the flame image
Let the fireplace burn for at least 20 minutes at
highest setting and check the flame for:
flame distribution;
colour of the flames.
If one or both points are not acceptable then
check:
The position of the logs and/or the
amount of ash material.
The pipe connections for leaks.
(in case of blue flames);
That the correct flue restrictor is fitted
(see fig. 2.5);
The outlet:
o
Wall terminal has the correct
position and side up;
o
Roof terminal has the correct
position.
If the maximum lengths of the flue gas
outlet is not exceeded.
8
Instructions for client
Recommend that the fire should be
checked annually by a qualified specialist
to ensure the safe use and to guarantee a
long service life.
Provide instructions on the operation of:
o
the appliance;
o
the remote control;
o
if present, the App and its
settings.
Give advice and instructions on care and
cleaning of the glass:
Emphasize the danger of fingerprint burns
at the glass.
Handover to customer:
o
installation manual;
o
user manual;
o
decoration instruction card;
o
suction cups;
o
sample Faber glass polish.
9
Annual maintenance
Check
Check and clean if necessary:
the combustion chamber;
the burner
the pilot flame;
the wooden logs for breakage;
the glass(es);
the outlet.
Replace ash material if necessary.
Cleaning
Remove the front glass (see chapter 5).
You can clean the glass with Faber glass polish.
This is a specially formulated cleaning agent that
can be ordered at authorized Faber dealers.
Never use aggressive cleaning agents or abrasive
products.
Please note!
Avoid fingerprints on the glass; these are no
longer removable once the fire is used.
Now carry out check-up as described in chapter 7.
For an extensive maintenance instruction
"maintenance protocol gas fires" see:
10
Conversion to other gas type
This can only be done by replacing the burner. To
do so, please contact your dealer. Always provide
the type and serial number of the appliance when
ordering.
Summary of Contents for Relaxed L Smart
Page 1: ...Installation manual Relaxed M Smart Relaxed L Smart ENG 40010635 2010 ...
Page 2: ...Installation manual Relaxed M L Smart 1 ...
Page 3: ...Installation manual Relaxed M L Smart 2 ...
Page 4: ...Installation manual Relaxed M L Smart 3 1 1 1 2 1 3 1 4 1 5 1 6 ...
Page 5: ...Installation manual Relaxed M L Smart 4 1 7 2 0 2 1 2 2 2 3 2 4 2 5 A C B 1 2 ...
Page 6: ...Installation manual Relaxed M L Smart 5 ...
Page 15: ...Installation manual Relaxed M L Smart 14 12 Examples flue materials ...
Page 21: ...Installation manual Relaxed M L Smart 20 16 Troubleshooting guide ...
Page 22: ...Installation manual Relaxed M L Smart 21 ...
Page 23: ...Installation manual Relaxed M L Smart 22 17 Dimensional drawings 17 1 Relaxed M Smart ...
Page 24: ...Installation manual Relaxed M L Smart 23 17 2 Relaxed L Smart ...
Page 25: ...Installation manual Relaxed M L Smart 24 17 3 Remote access door A9299463 ...
Page 26: ...Installation manual Relaxed M L Smart 25 17 4 Ventilation grid article number A9296400 ...
Page 28: ...Installation manual Relaxed M L Smart 27 18 2 Log set Relaxed L Smart ...