Faber Presence Installation Manual And User'S Manual Download Page 21

 

20 

<

 

<

 

<

 

<

 

UK

IRL

pressing the OFF- key (fig. 2.0) or 

wait for ten seconds. 

 

Press the SET–key (fig. 1.8) again and 

now P2 

Ï

 (homecoming) will appear 

in the display screen, the time 

indication will start to blink and now 
set the starting time. 

 

Press the SET–key (fig. 1.8) again, 
now P2 

d

 (night) appears in the 

display screen, the time indication 

will start to blink and now set the 
starting time. 

 

Save the settings by pressing the OFF
key (fig. 2.0) or wait for ten seconds. 

 
 

22

 

Checkpoints in case of 
Malfunction 

 

If the remote control unit of the fire does not 

function properly, check the following points 
first: 

 

1.

 

Is the toggle switch (fig. 1.1) set to 

position I ? 

2.

 

Check the battery- (chapter. 18.5) 

3.

 

Check whether the receiver responds 
to the remote control unit. 

If necessary, reset the receiver. 
Therefore: 

Briefly pull the battery pack out and 
remove the batteries out the holder 

wait 1 min. before replacing the 
batteries , now the receiver is reset.  

 

If the remote control unit or the fire itself 

does not function properly after all these 
checks, we refer you to your gas fitter. 

 
 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 

 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 

Summary of Contents for Presence

Page 1: ...Presence Installation Guide and users manual GB IE GB IE 40011221 1138 ...

Page 2: ...1 UK IRL Installation Guide ...

Page 3: ...2 UK IRL 1 1 1 2 1 3 1 4 1 5 1 6 ...

Page 4: ...3 UK IRL 1 7 1 8 2 1 2 2 2 3 2 4 2 5 ...

Page 5: ...4 UK IRL 2 6 3 1 3 2 3 3 4 1 4 2 A B ...

Page 6: ...ion The first time the appliance is switched on Let the fire run on maximum setting for several hours so that the lacquer coating will have an opportunity to set and possible vapours released can be safely removed by ventilation We advise you to be outside the room as much as possible during this process Please note that 1 all transport packaging should be removed 2 children or pets should not be ...

Page 7: ... If necessary convert to framed version Therefore A Remove the build in frame see fig 3 1 B Fit the frame support see fig 3 2 C The frame now can be hung on the support see fig 3 3 4 3 Batteries The battery pack is fixed on a chain inside the burner unit on the right side see fig 2 2 Pull the chain to remove it To avoid overheating take care that the battery pack always is positioned correctly in ...

Page 8: ...hecking for gas leakage Check all connections and joints for possible gas leaks by means of a gas leak detector or spray 7 3 Checking the burner pressure and the inlet pressure Check whether the burner pressure and the inlet pressure measured agree with the data indicated on the registration plate 7 4 Measuring the inlet pressure Turn off the gas control Get access to the burner unit by removing t...

Page 9: ...sed and cannot be removed anymore 8 4 Check and cleanup debris To get access to the debris area remove the 1 glass see chapter 5 2 log set 3 burner unit Therefore Remove the bottom plates in the front and at the back see fig 2 3 Unscrew 4 screws 2 at the left and 2 at the right and remove the burner plate including the burner see fig 2 4 Disconnect the gas Unscrew 13 screws of the burner unit and ...

Page 10: ...7 Gas rate at 15ºC and 1013 mbar l h 542 150 181 Gas rate at 15ºC and 1013 mbar gr h 380 340 Burner pressure at full mark mbar 9 5 20 25 7 Injector main burner mm 2 1 1 3 1 3 Minimum screw mm 1 3 0 85 0 85 Pilot assembly OP9030 OP9222 OP9222 Diameter outlet mm 125mm 5 inch 125mm 5 inch 125mm 5 inch Gas control valve GV60 GV60 GV60 Gas connection 8mm 8mm 8mm Batteries receiver V 4x AA 1 5V 4x AA 1 ...

Page 11: ...10 UK IRL 11 Dimensions Presence Frameless Top outlet ...

Page 12: ...11 UK IRL 12 Dimensions Presence Frameless Rear outlet ...

Page 13: ...12 UK IRL 13 Dimensions Presence Framed Top outlet ...

Page 14: ...13 UK IRL 14 Dimensions Presence Framed Rear outlet ...

Page 15: ...14 UK IRL Users manual ...

Page 16: ...15 UK IRL 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 ...

Page 17: ...16 UK IRL 1 9 2 0 2 1 2 2 2 3 2 4 2 5 ...

Page 18: ...aterials in the combustion chamber Never change the position of the log set and never add more decorative materials or carrara pebbles than have been supplied with the appliance If the fire is switched on the pilot light should always be visible Don t place any curtains clothes laundry furniture or other inflammable materials in the neighbourhood of the appliance The minimum safe distance is 100 c...

Page 19: ...2 2 Wait or press the OFF key to terminate this function fig 2 0 19 2 Setting the transmitter code on the remote control unit Press the reset button of the receiver with a pointed object until the second signal is audible Now press the key on the remote control unit fig 2 1 within 20 seconds If a sound signal is audible the transmitter code has been set 19 3 Temperature clock setting standard C 24...

Page 20: ...of the periods for day and night temperatures is set within 24 hours 21 2 Setting day and night temperatures Move the SET key fig 1 8 step by step to ÏTEMP Now keep the SET key fig 1 8 pushed in for a long time until the temperature indication in the display screen starts to blink In accordance with your wishes increase the Day temperature with the key fig 2 1 or lower it with the key fig 2 2 Pres...

Page 21: ... or wait for ten seconds 22 Checkpoints in case of Malfunction If the remote control unit of the fire does not function properly check the following points first 1 Is the toggle switch fig 1 1 set to position I 2 Check the battery chapter 18 5 3 Check whether the receiver responds to the remote control unit If necessary reset the receiver Therefore Briefly pull the battery pack out and remove the ...

Page 22: ...21 UK IRL ...

Page 23: ...22 UK IRL ...

Page 24: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 ...

Reviews: