I = 6x

4

5

6

7

12a

x2

Ø 

8

 mm

x2

x2

Installation screws provided must be secured 

with wall plugs (purchase separately).

From inside the Hood body, mark the security 

hole, drill ø 5/16" where marked, insert 2 wall 

plugs 11 in the holes and fix with 2 screws.

5/16"

Fix the brackets 7.1 using the 12a screws 

supplied in the hood body fixing holes as 

shown.

Screw the two screws 12d supplied onto the 

brackets 7.1.

Hook the hood body onto the bracket 7.1, 

centering it around the vertical line.

Use the adjusting screws 12d underneath the 

hood to level the hood body.

12a

Summary of Contents for Nova PRO

Page 1: ...NOPR30SS600 NOPR36SS600 Installation Instructions Use and Care Information Instructions d installation Utilisez et d entretien Instrucciones de instalación Información de uso y cuidado Nova PRO ...

Page 2: ...e with your back to an exit Based on Kitchen Firesafety Tips published by NFPA WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK do not use this fan with any solid state speed control device WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufactu...

Page 3: ...ouldbeinstalledtominimizebackwardcoldairflowandanonmetal lic thermal break should be installed to minimize conduction of outside temperatures as part of the vent system The damper should be on the cold air side of the thermal break The break should be as close as possible to where the vent system enters the heated portion of the house VENTING REQUIREMENTS Determine which venting method is best for...

Page 4: ...for grounding DO NOT ground to a gas pipe DO NOT have a fuse in the neutral or grounding circuit A fuse in the neutral or grounding circuit could result in electrical shock Check with a qualified electrician if you are in doubt as to whether the rangehood is properly grounded Failure to follow electrical requirements may result in a fire WARNING ...

Page 5: ...5 RANGEHOOD DIMENSIONS Min 24 Min 30 ...

Page 6: ... 12e 3 Screws 1 8 x 1 4 Qty Documentation 1 Instruction Manual Available Accessories Direct Connect Wiring Box sku number WIREBOX Activated Charcoal Filter sku FILTER1LL High Ceiling Chimney Kit Upper and Lower Chimney Flue to replace the original flue s to fit up to 11 ceilings sku HIGH3 sku CFMRED2 Ductless Kit Includes Ductless Diverter Two Charcoal Filters sku DUCT5 Wireless Remote Control REM...

Page 7: ...Requires purchase of Activated Charcoal Accessory Horizontal Vertical 6 I Install Damper that is included with the Hood before connecting to the ductwork Only for Ducted Venting Installation Remove the filters one at a time supporting them with one hand and turning the safety knobs pull and turn 1 ...

Page 8: ...8 6 Rear Ducted Venting Options Installation Ducting Methods The Electrical Connector must be removed first before converting the hood to Rear Ducting mode Rear Ducted Venting diagram ...

Page 9: ... using light force on one tab with a flat head screwdriver Remove the 2 screws as shown in the image to the left from the top electrical cover and set aside As shown in the image to the left pull out the loose cable with the electrical cover and set aside Caution Do not damage the Cable ...

Page 10: ...tallation the motor needs to be unsecured by first removing the 12 screws as shown Once the screws are removed extract the blower from the body of the Hood and position it so the transition opening is facing to the rear wall from the back remove and rotate 180 degrees to the left and then flip it back 90 degrees as shown in the diagram ...

Page 11: ...Hood body Reconnect the Connectors to the blower Fix the Supplied Cover with 3 screws 12e As shown in the image to the right take the cable and cover removed previously and place back in original position and secure with the 2 screws removed previously Caution Do not damage the Cable ...

Page 12: ...al reference lineandmarkthewallatthecentersoftheholesinthebracket Place the other bracket 7 2 1 on the wall as shown below the first bracket at the height of the upper chimney section supplied and aligning the centers notch with the vertical line Mark the wall at the centers of the holes in the bracket Place bracket 7 1 as shown 5 13 16 from the vertical reference line and 7 1 2 above the horizont...

Page 13: ...where marked insert 2 wall plugs 11 in the holes and fix with 2 screws 5 16 Fix the brackets 7 1 using the 12a screws supplied in the hood body fixing holes as shown Screw the two screws 12d supplied onto the brackets 7 1 Hook the hood body onto the bracket 7 1 centering it around the vertical line Use the adjusting screws 12d underneath the hood to level the hood body 12a ...

Page 14: ...2 1 using the screws 12a supplied 12 Slightly widen the two sides of the lower section and hook them between the upper section and the wall making sure that they are properly housed Install Roof or Wall Cap purchased separately Con nect the 6 metal ductwork to the Roof or Wall Cap and then attach ductwork Vertical or Horizontal Ducting Installation L 4x 12a N 4x 12b 2 1 Fix the the lower chim ney ...

Page 15: ...brackets and connect to the Ductless Diverter mak ing sure that they are well seated 15 12a Fix the lower Bracket 7 2 1 with two screws 12a supplied as shown N 4x 12b Secure the sides to the brackets by using the 4 screws 12b 2 2 2 1 18 19 Slightly widen the two sides of the the lower chimney hood and hook them between the upper section and the wall making sure that they are properly housed Fix th...

Page 16: ...egroundinginstructions are not completely understood or if doubt exists as to whether the appliance is properly grounded Do not use an extension cord If the power supply cord is too short have a qualified electrician install an outlet near the appliance ELECTRICAL INSTALLATION WITH OPTIONAL WIRING BOX For Permanent wiring Installation Use only with Listed rangehood Wiring Box kit sku WIREBOX manuf...

Page 17: ...activate the INTENSIVE SPEED which is timed to run for 10 minutes At the end of this time it will automatically return to the speed set before Suitable to deal with maximum levels of cooking fumes If you hold this button down for 2 seconds when the hood is off then after 2 minutes the motor will shut off L Light Button Press the LIGHT button to turn the light on and again to turn off T1 T2 T3 T4 L...

Page 18: ...he safety knobs provided pull and turn Replacing Activated Charcoal Filter The Activated Charcoal Filters are not washable and cannot be regenerated and should be replaced approximately every 4 months of operation or more frequently with heavy usage Remove the charcoal filter by rotating it clockwise backwards until it unlocks from the motor housing and pull off sideways To re insert each charcoal...

Page 19: ...19 Wiring Diagram ...

Page 20: ...rom accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical or plumbing codes or Faber documentation or use of products not approved by Faber 5 Replacement parts or repair labor costs for units operated outside the United States or Canada including any non UL or C UL approved Faber range hoods 6 Repairs to the hood resulting from...

Reviews: