background image

I n s t a l l a t i o n   I n s t r u c t i o n s

I n s t a l l a t i o n   I n s t r u c t i o n s

12  Examples flue materials

   

 

 

 

fig. 12.1 

 

 

 

 

 

 

 

 

 

fig.12.2 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fig. 12.3 

 

 

 

 

 

 

 

 

 

 

 

 

  

2 3

Summary of Contents for MatriX 1050 Series

Page 1: ...MatriX 1050 serie 40011616 1714 MatriX 1050 ENG...

Page 2: ...I n s t a l l a t i o n I n s t r u c t i o n s 2 1 0 1 2 1 1 1 3...

Page 3: ...I n s t a l l a t i o n I n s t r u c t i o n s 3 1 4 1 5 1 6 1 7 1 8 D E...

Page 4: ...I n s t a l l a t i o n I n s t r u c t i o n s 4 2 0 2 1 F G 1 9...

Page 5: ...I n s t a l l a t i o n I n s t r u c t i o n s 5 2 2 2 3 2 4 H H I I...

Page 6: ...I n s t a l l a t i o n I n s t r u c t i o n s 6 J L K H H 2 7 2 5 2 6...

Page 7: ...I n s t a l l a t i o n I n s t r u c t i o n s 7 2 9 2 8...

Page 8: ...I n s t a l l a t i o n I n s t r u c t i o n s 8 B B A C 3 0 3 1 1 2 3 3 1 C 2 3 4 3 3 2 3 3...

Page 9: ...I n s t a l l a t i o n I n s t r u c t i o n s 9 3 4 1 2 3 5...

Page 10: ...I n s t a l l a t i o n I n s t r u c t i o n s 1 0 4 0 4 1 4 2...

Page 11: ...I n s t a l l a t i o n I n s t r u c t i o n s 1 1 4 3 4 4 4 5...

Page 12: ...I n s t a l l a t i o n I n s t r u c t i o n s 1 2 4 6...

Page 13: ...rials and carpeted floors etc are attracted These parts can settle as soot on cold surfaces Therefore do not light the fire shortly after installation Light the fire for the first time and run for sev...

Page 14: ...mney must be in good condition no leakage well cleaned For more information about connections to existing chimneys ask the installation manual chimney connection set 4 Preparation and installation ins...

Page 15: ...stance profile fig 2 4 J upper side flange combustion chamber fig 2 5 K distance holder glass support fig 2 6 L distance holder glass support fig 2 6 Please note Ensure that the fire is not load beari...

Page 16: ...nd pipes for gas leakage 7 3 Checking the burner pressure and primary pressure Check that the burner pressure and primary pressure match with the information listed in the manual Chapter 14 Technical...

Page 17: ...table we work with start length STL total vertical height TVH and total horizontal length THL Start length STL This is the first part that is placed on the fire and represents a certain value fig 12...

Page 18: ...2 0 2 x x x x x x x x 11 60 2 30 2 0 2 x x x x x x x x 12 60 2 30 2 0 2 x x x x x x x x 13 70 2 30 2 0 2 x x x x x x x x 14 70 2 30 2 30 2 0 2 x x x x x x x 15 70 2 30 2 30 2 0 2 x x x x x x x 16 70 2...

Page 19: ...40 4 x x 10 50 4 50 3 50 4 50 4 50 4 45 4 45 4 x x 11 60 4 60 3 60 4 50 4 50 4 50 4 45 4 x x 12 60 4 60 3 60 4 60 4 50 4 50 4 50 4 x x 13 60 4 60 3 60 4 60 4 60 4 50 4 50 4 x x 14 70 4 70 3 60 4 60 4...

Page 20: ...0 4 x x 10 50 4 50 3 50 4 50 4 50 4 45 4 45 4 x x 11 60 4 60 3 60 4 50 4 50 4 50 4 45 4 x x 12 60 4 60 3 60 4 60 4 50 4 50 4 50 4 x x 13 60 4 60 3 60 4 60 4 60 4 50 4 50 4 x x 14 70 4 70 3 60 4 60 4 6...

Page 21: ...4 60 4 60 4 60 4 60 4 60 4 x x x x 11 70 4 70 4 70 4 60 4 60 4 60 4 60 4 x x x x 12 70 4 70 4 70 4 70 4 60 4 60 4 60 4 x x x x 13 70 4 70 4 70 4 70 4 70 4 60 4 60 4 x x x x 14 70 4 70 4 70 4 70 4 70 4...

Page 22: ...60 4 60 4 60 4 60 4 x x x x 11 70 4 70 4 70 4 60 4 60 4 60 4 60 4 x x x x 12 70 4 70 4 70 4 70 4 60 4 60 4 60 4 x x x x 13 70 4 70 4 70 4 70 4 70 4 60 4 60 4 x x x x 14 70 4 70 4 70 4 70 4 70 4 70 4...

Page 23: ...I n s t a l l a t i o n I n s t r u c t i o n s 12 Examples flue materials fig 12 1 fig 12 2 fig 12 3 2 3...

Page 24: ...ntal direction x 1 5 45 Bend in horizontal direction x 1 flue pipes at an angle in meters x 0 7 meter Value Starter length STL First part on top of the appliance Flue length from 0 1m till 0 45m Flue...

Page 25: ...er just before the terminal Wall terminal 130 200 0 4 Restrictor size Value for the comma Extra information Value behind the comma Search in the table at TVH and THL and enter the value that is found...

Page 26: ...r h 720 710 Burner pressure at full mark mbar 10 5 21 28 4 Injector main burner mm 4x 1 3 1x 1 6 1x 0 8 4x 0 9 1x 0 8 4x 0 9 Reduced input restraint mm adjustable adjustable adjustable Pilot flame SIT...

Page 27: ...13 mbar gr h 860 830 Burner pressure at full mark mbar 13 8 20 5 27 1 Injector main burner mm 4x 1 3 1x 1 6 5x 0 9 5x 0 9 Reduced input restraint mm 2 1 1 6 1 6 Pilot flame SIT145 SIT145 SIT145 Code p...

Page 28: ...ets against over each other 1000 L Distance between two roof outlets 450 M Two roof outlets above each other on a pitched roof 1000 N Two gable outlets next to each other 1000 Short roof terminal Only...

Page 29: ...t of a small piece from the sparking plug Tie wraps removed Cable is free from any metal parts 4x 1 5V AA Alkaline Thermocouple circuit is interrupted check 8 wire cable from receiver to the gas valve...

Page 30: ...ot burner is leaking Gasket between burner unit is leaking Glass seal is leaking Flue parts aren t 100 connected check flue system Replace batteries in the receiver Check the distance from thermocoupl...

Page 31: ...ulty parts RESET the receiver Gas vlave broken poor or loose contact Short circuit in wiring Install a ground cable from the gas valve to the appliance Optional Step burner function can be turned ON a...

Page 32: ...I n s t a l l a t i o n I n s t r u c t i o n s 3 2 17 Dimensional drawings 17 1 MatriX 1050 500 I...

Page 33: ...I n s t a l l a t i o n I n s t r u c t i o n s 3 3 17 2 MatriX 1050 500 IIL...

Page 34: ...I n s t a l l a t i o n I n s t r u c t i o n s 3 4 17 3 MatriX 1050 500 IIR...

Page 35: ...I n s t a l l a t i o n I n s t r u c t i o n s 3 5 17 4 MatriX 1050 500 III...

Page 36: ...I n s t a l l a t i o n I n s t r u c t i o n s 17 5 MatriX 1050 650 I 3 6...

Page 37: ...I n s t a l l a t i o n I n s t r u c t i o n s 17 6 MatriX 1050 650 IIL 3 7...

Page 38: ...I n s t a l l a t i o n I n s t r u c t i o n s 17 7 MatriX 1050 650 IIR 3 8...

Page 39: ...I n s t a l l a t i o n I n s t r u c t i o n s 17 8 MatriX 1050 650 III 3 9...

Page 40: ...I n s t a l l a t i o n I n s t r u c t i o n s 17 9 Wall bracket 1050 500 4 0...

Page 41: ...I n s t a l l a t i o n I n s t r u c t i o n s 17 9 Wall bracket 1050 650 4 1...

Page 42: ...I n s t a l l a t i o n I n s t r u c t i o n s 4 2 17 10 Remote acces door...

Page 43: ...I n s t a l l a t i o n I n s t r u c t i o n s 4 3 17 11 Ventilation grid...

Page 44: ...I n s t a l l a t i o n I n s t r u c t i o n s 4 4 17 12 Adjustable feet...

Page 45: ...I n s t a l l a t i o n I n s t r u c t i o n s 4 5...

Page 46: ...I n s t a l l a t i o n I n s t r u c t i o n s 4 6...

Page 47: ...I n s t a l l a t i o n I n s t r u c t i o n s 4 7...

Page 48: ...I n s t a l l a t i o n I n s t r u c t i o n s 4 8 www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen Dealerinfo...

Reviews: