![Faber MatriX 1050/650-I Installation Instructions Manual Download Page 15](http://html.mh-extra.com/html/faber/matrix-1050-650-i/matrix-1050-650-i_installation-instructions-manual_535925015.webp)
Installation Instructions
15
4.6.3
Method I (fig. 2.2)
The appliance can be wall-mounted with the optional wall bracket
(see fig. 1.8).
•
When penetrating a non-combustible wall or ceiling the
opening must be at least 5mm larger than the diameter of the
discharge material. At a combustible wall or ceiling is this
100mm larger than the diameter of the drainage material.
•
Horizontal sections should be installed with a slope towards
the fire (3 degrees).
•
Build the system from the fire. If this is not possible you can
make use of an extendable adapter section.
•
For truing up the exhaust system use the 0,5m. pipe, which
can be shortened and ensure that the inner pipe is always
2cm longer than the outer pipe.
•
Parts, which are shortened, must be secured with a
self-tapping screw.
•
Wall and roof terminals can also be cut.
•
Do not insulate but ventilate built-in flue material (approx.
100cm²).
If possible, carry out a performance test at the fire before finally
finishing the installation.
4.6.1
False chimney
*
Construct the false chimney of non-combustible material in
combination with metal profiles or of masonry/concrete
blocks.
*
Be aware of ventilation grids and service door (see fig. 1.0 to
1.5). Place above the ventilation grids a screen plate made of
non-combustible material (see fig. 1.1, 1.3 or 1.5)
*
Always use a lintel or reinforcing bars while bricking the
outlet. They should not be placed directly on the fire.
*
Built the false chimney against the appliance (see fig. 1.0 to
1.5). Keep a minimum distance of 2mm between the false
chimney and the appliance, because of the extension of the
appliance.
4.6.2
Installation and finishing
For installation and finishing the following points are of interest:
H = moldings (fig. 2.4 and 2.7)
I = distance profile (fig. 2.4)
J = upper side flange combustion chamber (fig. 2.5)
K = distance holder/glass support (fig. 2.6)
L = distance holder/glass support (fig. 2.6)
>
Please note:
Ensure that the fire is not load-bearing with regard to the false
chimney breast.
Build the false chimney breast against the moldings H and distance
profiles I (see fig. 2.4 and 2.7).
Keep a minimum distance of 2mm between the false chimney and
the appliance, because of the extension of the appliance. Take into
account the thickness of the finish!
4.6.4
Method II (fig. 2.3)
Remove the distance profiles “I” (see fig. 2.4).
Make sure that the screws of the front distance profile “I” will be
replaced, in order to ensure the air tightness of the appliance.
For the height of the plateau, see point “J” (fig. 2.5).
See fig. 2.6, distance profiles K and L. Keep a minimum distance of
2mm because of the extension of the appliance.
5 Removing theglass
MatriX 1050/650-I
•
Remove the moldings “A” left and right (fig. 3.0).
•
Turn the left and right side clamps “B” up (fig. 3.0).
•
Place the suction cups on the glass and slide the upper list
“C” up (fig. 3.1).
•
See fig. 3.2, number:
1.
Slide the glass to the top so that the bottom will
release.
2.
Now, carefully slide the glass to the left.
3.
Get the released side towards to you and put the glass
on a safe place.
MatriX 1050/650-IIL and 1050-650-IIR
•
Remove molding “A” left or right (fig. 3.0).
•
Turn the left or right side clamps “B” up (fig. 3.0).
•
Place the suction cups on the glass and slide the upper list
“C” up (fig. 3.3).
•
See fig. 3.3, number:
1.
Slide the glass to the top so that the bottom will
release.
2.
Now, carefully slide the glass to the left or to the right.
3.
Get the released side towards to you and put the glass
on a safe place.
MatriX 1050/650-III
•
Place the suction cups on the glass and slide the upper list
“C” up (fig. 3.3).
•
See fig. 3.3, number:
1.
Slide the glass to the top so that the bottom will
release.
4.
Get the released side towards to you and put the glass
on a safe place.
4.5
Installing the flue materials
4.6
Constructing the false chimney
5.1
Removing the glass from the front
4.4.1
Hanging on the wall (1050/650-IIL,-IIR and
1050/650-III)
Summary of Contents for MatriX 1050/650-I
Page 1: ...40011616 1623 MatriX 1050 650 ENG MatriX 1050 650 ...
Page 2: ...Installation Instructions 1 2 1 3 2 1 0 1 1 ...
Page 3: ...Installation Instructions 1 8 1 9 3 D E 1 4 1 5 1 6 1 7 ...
Page 4: ...Installation Instructions 4 2 0 2 2 2 1 ...
Page 5: ...Installation Instructions 2 4 5 2 3 ...
Page 6: ...Installation Instructions 6 2 5 K 2 6 2 7 ...
Page 7: ...Installation Instructions 2 9 7 I T C versie Symax versie 2 8 ...
Page 8: ...Installation Instructions 8 3 0 3 1 3 2 3 3 ...
Page 9: ...Installation Instructions 9 3 4 3 5 ...
Page 10: ...Installation Instructions 10 4 0 4 1 4 2 4 3 ...
Page 11: ...Installation Instructions 11 4 4 4 5 ...
Page 12: ...Installation Instructions 12 WRONG OK 4 6 ...
Page 22: ...Installation Instructions 22 12 Examples flue materials fig 12 1 fig 12 2 fig 12 3 ...
Page 30: ...Installation Instructions 30 17 Dimensional drawings 17 1 MatriX 1050 650 I ...
Page 31: ...Installation Instructions 31 17 2 MatriX1050 650 IIL ...
Page 32: ...Installation Instructions 32 17 3 MatriX1050 650 IIR ...
Page 33: ...Installation Instructions 33 17 4 MatriX1050 650 III ...
Page 34: ...Installation Instructions 34 17 5 Wall bracket ...
Page 35: ...Installation Instructions 35 17 6 Remote acces door ...
Page 36: ...Installation Instructions 36 17 7 Ventilation grid ...
Page 37: ...Installation Instructions 37 17 8 Adjustable feet ...
Page 38: ...Installation Instructions 38 ...
Page 39: ...Installation Instructions 39 ...
Page 40: ...Installation Instructions 40 ...