![Faber MatriX 1050/500 I Installation Manual Download Page 17](http://html.mh-extra.com/html/faber/matrix-1050-500-i/matrix-1050-500-i_installation-manual_535922017.webp)
Installation manual MatriX 1050/500 I,II,III H & MatriX 1050/650 I,II,III H
17 <
<
<
<
7.2
Flue gas analysis
It is possible to check the combustion gases and
supply air with a CO/CO
2
flue gas analyser.
There are two measuring pipes between the built-
in frame and the front glass (fig. 2.1).
X = measuring pipe air supply
Y = measuring pipe flue gas
The ratio CO2 and CO must not be greater than
1:100.
Example:
CO2 is 4% and CO is 400ppm, measured at the
highest point. If the ratio is greater than 1:100 or
flue gases are measured in the air supply, check
the points in section 7.1.
8
Instructions for client
Recommend that the fire should be
checked annually by a qualified specialist
to ensure the safe use and to guarantee a
long service life.
Provide instructions on the operation of:
o
the appliance;
o
the remote control;
o
if present, the App and its set-
tings.
Give advice and instructions on care and
cleaning of the glass:
Emphasize the danger of fingerprint burn-
in at the glass.
Handover to customer:
o
installation manual;
o
user manual;
o
decoration instruction card;
o
suction cups;
o
sample Faber glass polish.
9
Annual maintenance
Check
Check and clean if necessary:
the combustion chamber;
the burner;
the wooden logs for breakage;
the glass(es);
the outlet.
Replace ash material and/or glass granules if nec-
essary.
Cleaning
Remove the front glass (see chapter 5).
You can clean the glass with Faber glass polish.
This is a specially formulated cleaning agent that
can be ordered at authorized Faber dealers.
Never use aggressive cleaning agents or abrasive
products.
Please note!
Avoid fingerprints on the glass; these are no
longer removable once the fire is used.
Now carry out check-up as described in chapter 7.
For an extensive maintenance instruction "mainte-
nance protocol gas fires" see:
10
Conversion to other gas type
This can only be done by replacing the burner. To
do so, please contact your dealer. Always provide
the type and serial number of the appliance when
ordering.
Summary of Contents for MatriX 1050/500 I
Page 1: ...Installation manual MatriX 1050 500 I II III H MatriX 1050 650 I II III H ENG 40012085 2223 ...
Page 2: ...Installation manual MatriX 1050 500 I II III H MatriX 1050 650 I II III H 2 ...
Page 3: ...Installation manual MatriX 1050 500 I II III H MatriX 1050 650 I II III H 3 ...
Page 9: ...Installation manual MatriX 1050 500 I II III H MatriX 1050 650 I II III H 9 3 9 4 0 4 1 ...
Page 10: ...Installation manual MatriX 1050 500 I II III H MatriX 1050 650 I II III H 10 ...
Page 41: ...Installation manual MatriX 1050 500 I II III H MatriX 1050 650 I II III H 41 ...
Page 42: ...Installation manual MatriX 1050 500 I II III H MatriX 1050 650 I II III H 42 ...
Page 43: ...Installation manual MatriX 1050 500 I II III H MatriX 1050 650 I II III H 43 ...