Installation requirements
3.1
Appliance
This appliance may not be installed in a
chlorine-containing environment. (Pools
etc.).
Minimal distance to combustible
materials:
o
Rear side 70mm;
o
Front 500mm;
o
Sides 500mm;
o
Under side 330mm;
3.2
Discharge and outlet requirements
First, carry out a flue calculation (see chapter 11)
and place the right flue restrictor before installing
the outlet! (Generally a 30mm flue restrictor is
installed).
For supply and discharge always use the
prescribed and to be supplied Faber flue
materials. Please contact Glen Dimplex
Benelux B.V.. Only with use of these
materials Faber can guarantee proper
performance.
The distance to combustible materials
must be min. 50mm, calculated from
outside of the flue material (EN 1856-1
T600 N1 D Vm – L20040 O(50)).
Outlets (fig. 1.2)
The balanced flue pipe for combined air supply and
discharge can use a wall terminal or a roof
terminal. Verify that the desired outlet meets the
local regulations regarding pollution and
ventilation openings.
Please note!
For proper functioning, the outlet must at
least be 0,5m away from:
Corners of the building;
Roof overhangs and balconies;
Roof edges (with the exception of the
ridge edge, see chapter 15).
C11, outlet via facade
Through a wall or façade, use a Faber wall outlet.
Depending on the flue calculation this can be
100/150mm or 130/200mm.
C31, outlet via roof
For a (flat) roof, use a Faber roof outlet with a
diameter of 100/150mm.
C91, existing chimney
For an existing chimney, use a Faber chimney
outlet with a diameter of 100/150mm.
In this case the existing chimney acts as air inlet an
inserted flexible stainless steel pipe discharges the
flue gas. The top (Faber chimney cover plate) and
the bottom (Faber chimney connection set) should
be airtight.
Depending on the calculated flue diameter, you
must use a flexible stainless steel pipe of
Ø100mm (article number AJ005503) or Ø130mm
(article number AJ005603) as specified by Faber.
For this, contact Glen Dimplex Benelux B.V.
Please note!
The minimum chimney diameter for a
130mm flexible stainless steel pipe must
be 200x200mm and for a 100mm flexible
stainless steel pipe and 150x150mm.
Don’t connect more than one fire at the
existing chimney.
The chimney must be in good condition:
o
No leakage;
o
Well cleaned.
For more information about the connections to
existing chimney ducts, please request the
installation instructions “Chimney Connection Set”.
4
Preparation and installation
instructions
4.1
Gas connection
The gas connection must comply with the
applicable local standards.
Please note!
Calculate the gas pipe so that no
pressure drop occurs.
We advise using a gas connection directly from the
gas meter to the appliance (see dimensional
drawing 17.2), with a shut-off valve in the
proximity of the appliance, which must always be
freely accessible. Position the gas connection so
that it is easily accessible for service and the
burner unit can be disassembled at any time.
4.2
Electrical connection
Install a 230VAC/50Hz wall socket near the
fireplace for connecting the control unit.
See fig. 1.3a for the wiring diagram:
A = Adapter (6 V)
B = Gas valve
C = Receiver
D = Ignition pin
Summary of Contents for JELLING
Page 1: ...Installation manual Jelling ENG 40010705 2010 ...
Page 2: ...Installation manual Jelling 1 ...
Page 3: ...Installation manual Jelling 2 ...
Page 4: ...Installation manual Jelling 3 1 1 1 2 1 3a 1 3b ...
Page 5: ...Installation manual Jelling 4 1 4 1 5 1 6 1 7 1 8 2 0 2 1 1 2 A ...
Page 6: ...Installation manual Jelling 5 2 2 2 3 ...
Page 14: ...Installation manual Jelling 13 12 Examples flue materials ...
Page 19: ...Installation manual Jelling 18 16 Troubleshooting guide ...
Page 20: ...Installation manual Jelling 19 ...
Page 21: ...Installation manual Jelling 20 17 Dimensional drawings 17 1 Jelling ...
Page 22: ...Installation manual Jelling 21 17 2 Position gas connection ...
Page 23: ...Installation manual Jelling 22 18 Decoration instruction card ...
Page 24: ...Installation manual Jelling 23 ...
Page 25: ...Installation manual Jelling 24 ...
Page 26: ...Installation manual Jelling 25 ...