Installation manual Jelling
9 <
<
<
<
Assess whether the flame distribution is
good. Move or remove any ash material to
create a nice glow bed.
Install the front glass and check the fire
image.
7
Checking the installation
Checking for gas leaks
Check with a gas leak finder all connections and
pipes for gas leakage.
Check primary- and burner pressure
Check if the primary pressure correspond to the
data on the rating plate.
Measuring the primary pressure:
Close the shutoff valve. Turn the
measuring nipple “A” (fig. 1.1) a few turns
to open and connect a measuring hose to
the gas valve.
Take this measurement when the
fireplace runs at high and low settings.
Do not use the device if the pressure
deviates (+20% or -20%).
Measuring the burner pressure:
Check the burner pressure only with proper
primary pressure.
Turn measuring nipple “B” (see fig. 1.1)
some turns open and connect a measuring
hose to the gas valve.
The pressure must correspond to the
value indicated in the technical
specifications of this manual. In case of
deviation contact the manufacturer.
Please note!
Close both pressure measuring nipples and
check for gas leakage.
Check ignition and burner
Ignite the fireplace by using the remote control as
described in the user manual and test all burner
possibilities.
7.1
Checking the flame image
Let the fireplace burn for at least 20 minutes at
highest setting and check the flame for:
flame distribution;
colour of the flames.
If one or both points are not acceptable then
check:
The position of the logs and/or the
amount of ash material.
The pipe connections for leaks.
(in case of blue flames);
That the correct flue restrictor is fitted
(see fig. 1.4-A);
The outlet:
o
Wall terminal has the correct
position and side up;
o
Roof terminal has the correct
position.
If the maximum lengths of the flue gas
outlet is not exceeded.
8
Instructions for client
Recommend that the fire should be
checked annually by a qualified specialist
to ensure the safe use and to guarantee a
long service life.
Provide instructions on the operation of:
o
the appliance;
o
the remote control;
o
if present, the App and its
settings.
Give advice and instructions on care and
cleaning of the glass:
Emphasize the danger of fingerprint burns
at the glass.
Handover to customer:
o
installation manual;
o
user manual;
o
decoration instruction card;
o
suction cups;
o
sample Faber glass polish.
9
Annual maintenance
Check
Check and clean if necessary:
the combustion chamber;
the burner
the pilot flame;
the wooden logs for breakage;
the glass(es);
the outlet.
Replace ash material and if necessary.
Summary of Contents for JELLING
Page 1: ...Installation manual Jelling ENG 40010705 2010 ...
Page 2: ...Installation manual Jelling 1 ...
Page 3: ...Installation manual Jelling 2 ...
Page 4: ...Installation manual Jelling 3 1 1 1 2 1 3a 1 3b ...
Page 5: ...Installation manual Jelling 4 1 4 1 5 1 6 1 7 1 8 2 0 2 1 1 2 A ...
Page 6: ...Installation manual Jelling 5 2 2 2 3 ...
Page 14: ...Installation manual Jelling 13 12 Examples flue materials ...
Page 19: ...Installation manual Jelling 18 16 Troubleshooting guide ...
Page 20: ...Installation manual Jelling 19 ...
Page 21: ...Installation manual Jelling 20 17 Dimensional drawings 17 1 Jelling ...
Page 22: ...Installation manual Jelling 21 17 2 Position gas connection ...
Page 23: ...Installation manual Jelling 22 18 Decoration instruction card ...
Page 24: ...Installation manual Jelling 23 ...
Page 25: ...Installation manual Jelling 24 ...
Page 26: ...Installation manual Jelling 25 ...