![Faber INCA SD Series Installation Instructions Manual Download Page 14](http://html1.mh-extra.com/html/faber/inca-sd-series/inca-sd-series_installation-instructions-manual_3640120014.webp)
14
FOR INSTALLATIONS WITH LINERS
CUSTOM/WOOD
HOOD
STANDARD LINER
WARNING
!
When building a custom hood,
always follow all applicable
codes and standards.
1.
The custom/wood hood must have a sturdy base (3/4" plywood recommended) to
accomodate the cut-out for the Inca HC SS. The base must be recessed to accomodate
the height of the Liner (see
LINER DIMENSIONS
on Page 4). The Liner attaches to the
bottom of the base using screws appropriate for the size and material of your custom/
wood hood. The Inca HC SS inserts into the cut-out in the Liner and base.
2.
Position the rear section of the Liner so that it abuts the back edge of your custom/
wood hood. Using a pen, trace the outline of the pre-cut out. Remove the Liner and
proceed to
MAKE YOUR CUT-OUTS
on Page 7. Install both sections of the Liner and
proceed to I
NSTALL THE Range hood
on Page 7.
INCA HC SS
The Inca HC SS can be used with
custom cabinetry and hoods 30"
wide and up. Choose either a
custom liner or our Standard Liner
designed for 30" and 36" wide
installations.
Liners create a perfectly-sealed,
non-combustible finish for the
underside of your custom/wood
hood.
The Standard Liners are made up of
two sections: a larger, rear section
(pre-cut out for insertion of the
Inca Smart) and a front section for
a total adjustable depth between
16" and 17
7/8"
.
!!! IMPORTANT NOTE:
YOU
MUST REMOVE THE ADDITIONAL
PERFORATED SECTION AROUND
THE PRE-CUT-OUT WHEN
INSTALLING THE STANDARD
LINER WITH THE INCA HC SS
MODEL.
Consider the shape, size, and
weight of the Inca HC SS and Liner
to determine the configuration
of the custom/wood hood. See
Range hood AND CUT-OUT
DIMENSIONS AND LINER
DIMENSIONS
on Page 4.
FOR INSTALLATION WITH LINERS
When building a custom hood,
always follow all applicable codes and
standards.
WARNING
!
The Inca SD can be used with
custom cabinetry and hoods 30"
wide and up. Choose either a
custom liner or our Standard Liner
designed for 30" and 36" wide
installations.
Liners create a perfectly-sealed,
non-combustible finish for the
underside of your custom/wood
hood.
The Standard Liners are made
up of two sections: a larger, rear
section (pre-cut out for insertion of
the Inca Smart) and a front section
for a total adjustable depth between
16" and 17 7/8".
!!! IMPORTANT NOTE:
YOU
MUST REMOVE THE ADDITIONAL
PERFORATED SECTION
AROUND THE PRE-CUT-
OUT WHEN INSTALLING THE
STANDARD LINER WITH THE
INCA SD MODEL.
Consider the shape, size, and
weight of the Inca SD and Liner
to determine the configuration
of the custom/wood hood.
1. The custom/wood hood must have a sturdy base
(3/4" plywood recommended) to accomodate the cut-
out for the Inca SD. The base must be recessed to ac-
comodate the height of the Liner (see
LINER DIMEN-
SIONS
on Page 13). The Liner attaches to the
bottom of the base using screws appropriate for the
size and material of your custom/ wood hood.
The Inca SD inserts into the cut-out in the Liner and
base.
2. Position the rear section of the Liner so that it abuts
the back edge of your custom/ wood hood. Using a
pen, trace the outline of the pre-cut out. Remove the
Liner and proceed to
MAKE YOUR CUT-OUTS
. Install
both sections of the Liner and proceed to
INSTALL
THE Range hood
.
Summary of Contents for INCA SD Series
Page 6: ...6 Min 24 Min 30...
Page 17: ...17 Wiring Diagram 991 0530 011 H90 503 D00004494_00 120V 60Hz...
Page 23: ...23 Min 24 Min 30...
Page 34: ...34 Sch ma de c blage 991 0530 011 H90 503 D00004494_00 120V 60Hz...
Page 40: ...40 Min 24 Min 30...
Page 51: ...51 Diagrama de cableado 991 0530 011 H90 503 D00004494_00 120V 60Hz...
Page 53: ...53...
Page 54: ...54...
Page 55: ...55...