EN
1
5
15
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert the reduc-
er flange
9
on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Remove possible charcoal filters.
ø 150
9
ø 120
AIR OUTLET – RECIRCULATION VERSION
• Connect the Flange to the air outlet opening using a rigid or
flexible pipe of ø120 or 150 mm.
• To connect using a ø120 mm pipe, insert the reduction Flange
9
onto the Hood canopy outlet.
• Fasten the pipe using suitable pipe clamps. The materials re-
quired to do so are not provided.
• Fix the directional Grid
8
on the outlet, using 2 screws
12e
(2.9
x 9.5) provided.
• Make sure that the activated charcoal filters are present (see
paragraph on Activated Charcoal Filter Maintenance).
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch hav-
ing a contact gap of at least 3 mm..
APPLIANCE
IN LET
Summary of Contents for FABULA EVO+BK A90
Page 7: ...EN 7 7 Dimensions 512 794 520 802 537 880 537 880 512 794 520 802 ...
Page 26: ...FR 2 6 26 Encombrement 512 794 520 802 537 880 537 880 512 794 520 802 ...
Page 45: ...DE 4 5 45 Platzbedarf 512 794 520 802 537 880 537 880 512 794 520 802 ...
Page 64: ...ES 6 4 64 Dimensiones 512 794 520 802 537 880 537 880 512 794 520 802 ...
Page 83: ...GR 8 3 83 ιαστάσεις 512 794 520 802 537 880 537 880 512 794 520 802 ...
Page 102: ...RU 1 0 102 Габариты 512 794 520 802 537 880 537 880 512 794 520 802 ...
Page 117: ......
Page 118: ......
Page 119: ......