background image

 

Installation and user manual

 

 

2 < 

<

 

<

 

<

 

1

 

Dear user 

 
Congratulations on purchasing your Faber product!  
A  quality  product  which  will  provide  you  with  warmth 
and  atmosphere  for  many  years  when  used  correctly. 
Please  read  the  user  manual  before  using  the  fire. 
Should,  despite  the  careful  final  checks,  a  malfunction 
occur,  please  contact  your  dealer  or  Dimpco  (Glen 
Dimplex Ireland sales company) for assistance. 

 

 

Please note:

  

The  data  of  your  fire  is  available  in  the  user 
manual. 

 
Appliance data can be found on the type plate that can 
be found behind the lower vermiculite back wall inside 
the cassette. 
 
Dimpco Ltd 
Old Airport Road 
Cloghran 
Co Dublin 
Ireland 
Tel: 

+353 (0) 1842 8222 

Fax: 

+353 (0) 1842 4943 

Email: 

[email protected]

 

Web: 

www.dimpco.ie 

 

1.1

 

 Introduction 

 
Only have the appliance installed by a qualified installer 
according to local regulations. 
Read this installation manual properly. 

 

1.2

 

Please check 

 
Check  the  fire  for  transport  damage  and  report  any 
damage immediately to your dealer.  
 

1.3

 

CE Declaration  

 
Glen  Dimplex  Benelux  certifies  that  this  Faber  fire 
complies with the essential requirements for solid fuel 
build in fires. 
Model: Dimplex 510 I, 650 I, 700 I 
Guidelines EG: 89/106/EEC 
Harmonized  Standards:  NEN-EN-13240,  NEN/EN-
13240/A2 
This  Declaration  is  invalid,  if  without  the  written 
permission of Glen Dimplex Benelux: 

 

Changes are made to the appliance. 

 

The  fire  is  connected  to  exhaust  materials 
other than specified. 

 
 
 
 

2

 

Safety instructions. 

 

 

Please read these instructions carefully before 
installing or using this appliance. Failure to do 
so  may  result  in  damage  to  persons  and 
property.  

 

This  appliance  is  suitable  for  domestic 
heating  use  only  in  accordance  with  these 
operating  instructions.  Do  not  make  any 
unauthorised changes to the appliance. 

 

This appliance must be installed by a suitably 
qualified  competent  person  in  accordance 
with  BS8308,  Code  of  practice  for  installing 
domestic  heating  and  cooking  apliances 
burning  solid  mineral fuel.  Installation  must 
comply  with  all  Building  Regulations, 
including  those  referring  to 

Local  Authority 

Bye-Laws,  National  and  European  Standards 
and Codes of Practice.

 

 

Chimney  connections  and  fire  safety  must  be 
in  compliance  with  local  regulations  and 
standards  following  guidelines  EN  13384,  EN 
1856-2 and EN 15287. 

 

Do not install this appliance on a shared flue. 

 

Do  not  fit  an  extractor  fan  in  the  same 
room  as  this appliance. 

 

Ensure  there  is  adequate  combustion  air 
ventilation  in  the  room  in  accordance  with 
building standards. Do not obstruct any  of the 
air inlets or outlets on the appliance.  

 

Due  to  the  natural  air  convection  of  the 
appliance,  dust  particles  from  carpets  and 
disrupted  building  materials  or  uncured  paint 
volatiles  may  settle  on  cold  surfaces  after 
installation.    Once  installed  allow  some  time 
for  dust  to  settle  and  vacuum  clean  before 
lighting the appliance. 

 

This  appliance  operates  at  very  high 
temperatures and retains its heat for a period 
after  use.  Do  not  touch  any  surfaces while in 
use.  All  persons  including  children  and  the 
infirm  should  be  warned  of  this  and  not 
allowed  to  touch  any  surfaces  while  in  use. 
Please  use  a  suitable  fireguard  manufactured 
to BS 8423:2002 suitable for use with solid fuel 
appliances, to prevent contact when in use. 

 

Do  not  place  any  combustible  items  within 
1m  of  the  appliance  (e.g.  photographs, 
paintings, TV’s, etc.). Exposure of combustible 
items  to  hot  surfaces  or  radiated  heat  will 
cause damage and poses a serious fire risk. 

Summary of Contents for Dimplex 510 I

Page 1: ...Faber Dimplex cassettes 510 I 650 I 700 I ...

Page 2: ...Installation and user manual 1 1 1 1 2 1 3 1 4 ...

Page 3: ...or domestic heating use only in accordance with these operating instructions Do not make any unauthorised changes to the appliance This appliance must be installed by a suitably qualified competent person in accordance with BS8308 Code of practice for installing domestic heating and cooking apliances burning solid mineral fuel Installation must comply with all Building Regulations including those ...

Page 4: ... should be carried out by a suitably qualified engineer If work is being carried out on flammable or explosive materials in the vicinity of the stove the stove must be put out of operation If a chimney fire occurs shut the air intake extinguish the fire with sand and contact the fire department immediately 3 Installation requirements 3 1 Fluepipe and terminal requirements The chimney must be suite...

Page 5: ...y that a flammable and hazardous situation is avoided at all time Take adequate measures to prevent high temperatures in the chimneybreast and surrounding constructions This also applies to materials or objects behind walls etc Remove all packed parts out of the combustion chamber Check if any loose parts need to be removed from the ashtray Check the physical state and correct position of the heat...

Page 6: ...sed the door if the fire does not light immediately then keep the door a bit open for some time Let the fire burn for a while so that the chimney heats up properly 7 2 Heating Let the fire burn on smaller logs for some time so that a smoldering fuel bed will be formed Refill de cassette with bigger logs After 15 20 minutes the output can be adjusted by the combustion control handle fig 1 1 slide i...

Page 7: ...ood Flue gas temperature deg C 264 252 237 Flue gas volume g s 2 7 4 2 6 9 Min flue draft Pa 12 12 12 Nom Output kW 4 5 5 6 5 Efficiency 80 83 81 Wood length cm 25 25 25 Dust at 13 O2 mg Nm3 30 30 30 Consumption kg h 1 15 1 6 1 95 Flue size mm 150 150 180 Weight kg 65 74 87 Dimplex 510 I ...

Page 8: ...Dimplex 700 I Dimplex 650 I ...

Page 9: ...7 5 Changing the trim Remove bolt Lift and move forwards ...

Page 10: ...7 6 Removal of self closing mechanism Remove bolts and change replace trim Remove bolt ...

Page 11: ...Lift up and move forwards click and remove spring ...