Faber DAMA Use And Care Manual Download Page 15

Version 07/11 - Page 15

INSTALLATIONS SANS CONDUIT

Les installations sans conduit requièrent le 

Kit Pour Conver-

sion Du Conduit

 (

FIGURE 8)

.  N'utilisez pas le REGISTRE 

ROND 

(G  de  la  FIGURE  1)

    pour  les  Installations  sans 

conduit.  Le couvercle de CHEMINÉE INFÉRIEURE SANS 

LES TROUS 

(B de la FIGURE 1)

 doit être mis de côté 

(1 de 

la FIGURE 8)

.  

1.

  Insérer sous pression le DUCTLESS DIVERTER 

(5)

 ainsi 

obtenue dans la sorte d'air 

(de la FIGURE 8)

.  Appliquer les 

DIVERTER  EXTENSION  HORIZONTAL  pieces 

(4) 

sur  le 

DUCTLESS DIVERTER.

2

. Installer le FILTRE AU CHARBON 

(6) (de la FIGURE 9)

.

POUR TOUT LES INSTALLATIONS

1. 

Brancher  le  câble  d’alimentation  sur  la  hotte. Attacher  le  fil 

blanc du câble d’alimentation sur le fil blanc de la hotte avec une 

cosse. Attacher le fil noir du câble d’alimentation au fil noir de la 

hotte avec une cosse. Brancher le fil de mise à la terre vert (jaune 

et vert) sous la vis de mise à la terre verte.  Replacer le couvercle 

du compartiment de câblage.

2.

 Installer la CHEMINÉE SUPÉRIEURE 

(C de la FIGURE 10)

.  

Elargir légèrement les deux bords latériaux de la cheminée et les 

accrocher derrières les FIXATIONS DE CHEMINÉE 

(E)

; refermer 

jusqu'à la butée.  Fixer latéralement aux  FIXATIONS DE CHEMI-

NÉE 

(E)

 à l'aide des VIS DE CHEMINÉE 

(G)

.

3.

 Installer la CHEMINÉE INFÉRIEURE 

(B)

.  Elargir légèrement 

les deux bords latériaux de la cheminée et les accrocher entre la 

CHEMINÉE SUPÉRIEURE et le mur; refermer jusqu'à la butée.  

Fixer latéralement la partie inférieure au la HOTTE 

(A)

 à l'aide des 

VIS DE CHEMINÉE 

(G)

.

FIGURE 10

FIGURE 8

INSTALLATIONS SANS CONDUIT

Les VENT GRIDS (

2 et 3) 

sont insérées dans les trous, tel qu’il 

est illustré 

à la FIGURE 11

.  S'assurer également qu'elles sont 

bien insérées dans les DIVERTER EXTENSION HORIZONTAL 

pieces.

FIGURE 9

FIGURE 11

1. CHEMINÉE INFÉRIEURE AVEC TROUS 

2. VENT GRID GAUCHE

3. VENT GRID DROIT

4. DIVERTER EXTENSION HORIZONTAL (DEUX)

5. DUCTLESS DIVERTER

6. FILTRE CHARBON

D'ECHAPPEMENT D'AIR

Summary of Contents for DAMA

Page 1: ... 280 Four wire power supply must be used and the appliance wiring must be revised See Electrical Requirements LISEZ BIEN CETTE FICHE AVANT D INSTALLER LA HOTTE AVERTISSEMENT POURMINIMISERLERISQUED UNFEUDEGRAISSESURLATABLEDECUISSON a Nejamaislaisser un élément de la table de cuisson fonctionner sans surveillance à la puissance de chauffage maximale un renversement débordement de matière graisseuse ...

Page 2: ... General Ventilating Use Only Do Not Use To Exhaust Hazardous or Explosive Materials and Vapors WARNING TO REDUCE THE RISK OF FIRE ELECTRI CAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING InstallationWorkAndElectricalWiringMust Be Done By Qualified Person s In Accordance With All Applicable Codes And Standards Including Fire Rated Construction Sufficient air is needed for proper combustion and...

Page 3: ...écuritédufournisseurtelsqueceuxpubliés par l Association Nationale de la Sauvegarde contre l Incendie et l Association Américaine d Ingénieurs de Chauffage Frigorifaction et Air Climatisé ainsi que les codes municipaux En perçant un mur veillez à ne pas perforer un autre fil électrique Une ventilateur à évacuation extérieure doit être raccordée à l extérieur AVERTISSEMENT Le système d évacuation D...

Page 4: ...asuring Tape or Ruler Level Pencil Caulking Gun Duct Tape PARTS SUPPLIED FOR INSTALLATION 1 Hardware Package 1 Literature Package PARTS NEEDED FOR INSTALLATION 2 Conduit Connectors Power Supply Cable 1 Wall or Roof Cap All Metal Ductwork OPTIONAL ACCESSORIES AVAILABLE High Ceiling Chimney Kit One 40 upper chimney to replace 16 1 8 upper chimney that came with hood part HIGH1 Stainless Ductless Con...

Page 5: ... 8 upper chimney that came with the hood Note If 24 or 30 High Backsplash is being installed the distance between the bottom of the hood and the cooktop DISTANCE X IN FIGURE 4A is equal to the height of the Backsplash upper chimney cover lower chimney cover canopy x distancefromhoodtocooktop varies depending on installation min 24 suggested max 30 cabinet base 5 1 8 min 16 1 8 max 21 1 4 4 3 4 36 ...

Page 6: ...adjusted for ceilings between 8 3 4 and 9 1 8 depending onthedistancebetweenthebottomofthehood and the cooktop distance x Forshorterceilings havethechimneycover s cut at a sheet metal shop For higher ceiling installations the High Ceiling Chimney Kit includesanew40 upperchimneywhichwould replace the 16 1 8 upper chimney that came with the hood Note If 24 or 30 High Backsplash is being installed th...

Page 7: ...ving about 1 4 gap between the wall and the head of the screw 8 For ducted installations determine and make all necessary cuts in the wall for the ductwork Install the ductwork before the rangehood 9 Determine the proper location for the Power Supply Cable by making sure it 1 Allows the LOWER CHIMNEY COVER to hide the Field Wiring Compartment 2 Does not have ductwork blocking your access to the Fi...

Page 8: ... supply to the White lead of the rangehoodwithatwist ontypewireconnector AttachtheBlacklead of the power supply to the Black lead of the rangehood with a twist on type wire connector Attach the Power Supply Cable grounding lead to the green screw provided Using the 4 holes provided screw the Field Wiring Compartment to the wall as dictated by your Power Supply Cable location screws not provided Re...

Page 9: ... off Remove the 2 screws as indicated in FIGURE 14 that hold the light support and gently pull the support down from the hood Remove the lamp from the light support and replace with new lamp Replace the light support and fix it into place with the 2 screws An alternative method to replace the lamps is to use a 1 1 4 suction cup FIGURE 15 Attach the suction cup to the bulb and pull firmly down on t...

Page 10: ...lumbing 2 Service calls to repair or replace range hood light bulbs fuses or filters Those consumable parts are excluded from warranty coverage 3 Repairs when your range hood is used for other than normal single family household use 4 Damage resulting from accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical or plumbing codes ...

Page 11: ... documentation PIÈCES NÉCESSAIRES POUR L INSTALLATION 2 connecteurs de conduit Câble d alimentation 1 capuchon de mur ou de toit Conduit en métal ACCESSOIRES POUR L INSTALLATION Kit D extension Pour La Cheminée Plafond Haut Une cheminée supérieure de 40 po part HIGH1 Acier Inoxydable Kit Pour Conversion Du Conduit Pour installation sans conduit Il est fortement recommandé que toute ventilation pro...

Page 12: ...distance entre la hotte et la table de cuisson X en FIGURE 4A Celas accomplitenutilisantplus ou moins du couvercle de la cheminé supérieure Pour plafonds petit coupez les coverclecheminée s Pourplafonds haut utiliserKitD extensionPourLa Cheminée Plafond Haut NOTE Si un dosseret est utilise avec cette hotte la distance entre la hotte etlatabledecusiion XdelaFIGURE 4A est 24 po ou 30 po min max haut...

Page 13: ...o regardez la distance entre la hotte et la table de cuisson X en FIGURE 4B Cela s accomplit en utilisant plus ou moins du couvercle de la cheminé supérieure Pour plafonds petit coupez les covercle cheminée s Pour plafonds haut utiliser Kit D extension Pour La Cheminée Plafond Haut NOTE Si un dosseret est utilise avec cette hotte la distance entre la hotte et la table de cusiion X de la FIGURE 4B ...

Page 14: ...vis 8 Pour les installations avec conduit déterminer et faire toutes les coupes nécessaires dans le mur pour les conduits Installer les conduits avant la hotte 9 Déterminer l emplacement approprié pour le câble d alimentation Soyes sûr de 1 Cacher le compartiment de câblage avec la CHEMINÉE INFÉRIEURE 2 Le conduit ne pas bloquer le compartiment de câblage Utiliser un foret de 1 1 4 po pour faire u...

Page 15: ...une et vert sous la vis de mise à la terre verte Replacer le couvercle du compartiment de câblage 2 Installer la CHEMINÉE SUPÉRIEURE C de la FIGURE 10 Elargir légèrement les deux bords latériaux de la cheminée et les accrocher derrières les FIXATIONS DE CHEMINÉE E refermer jusqu à la butée Fixer latéralement aux FIXATIONS DE CHEMI NÉE E à l aide des VIS DE CHEMINÉE G 3 Installer la CHEMINÉE INFÉRI...

Page 16: ...mière halogène Avant d essayer de remplacer les ampoules s assurer que l interrupteur soit hors circuit Retirer les deux vis de la FIGURE 13 Retirer l ampoule et la remplacer par une nouvelle ampoule Une méthode alternative pour substituer les lampes est d utiliser des 1 1 4 tasses d aspiration de la FIGURE 14 Attachez la tasse d aspiration à l ampoule et tirez fermement vers le bas sur l ampoule ...

Page 17: ...es de votre maison ou pour corriger votre câblage ou votre système de plomberie 2 Les appels de service pour remplacer ou réparer les ampoules les fusibles ou les filtres de votre hotte de cuisinière 3 Les réparations lorsque votre hotte de cuisinière a été utilisée plus que la normale c est à dire plus que pour une famille par foyer 4 Les dommages résultant d un accident de l altération d une mal...