Installation manual Triple M,L Smart

 

9 < 

<

 

<

 

3

 

Installation requirements 

 

3.1

 

Appliance 

 

This appliance may not be installed in a 
chlorine-containing environment. (Pools 
etc.). 

 

This appliance must be built into an 
existing or new false chimney. 

 

For appliances with flexible gas pipes, the 
control unit (fig. 1.0) is placed on the right 
side of the crate for transport reasons. 
Detach and mount it together with the 
remote access door in as low as possible 
position in the false chimney. 
(To prevent damage to cables and pipes 
during transport, they are bound together 
by tie wraps. Remove these to ensure 
proper operation of the appliance.) 

 

If desired, a 2 meter pipe set is available 
(article number 20900715). 

 

3.2

 

False chimney 

 

The false chimney should be of non-
combustible material. 

 

The space above the fire should always be 
ventilated using grids with minimal free 
passage of 200cm² per grid.  

 

The false chimney construction should not 
rest on the build-in frame of the fireplace. 

 

3.3

 

Discharge and outlet requirements 

First, carry out a flue calculation (see chapter 11) 
and place the right flue restrictor before installing 
the outlet! (Generally a 30mm flue restrictor is 
installed). 

 

For supply and discharge always use the 
prescribed and to be supplied Faber flue 
materials. Please contact Glen Dimplex 
Benelux B.V.. Only with use of these 
materials Faber can guarantee proper 
performance. 

 

The distance to combustible materials 
must be min. 50mm, calculated from 
outside of the flue material (EN 1856-1 
T600 N1 D Vm – L20040 O(50)). 

 
Outlets (fig. 1.2) 
The balanced flue pipe for combined air supply and 
discharge can use a wall terminal or a roof 
terminal. Verify that the desired outlet meets the 
local regulations regarding pollution and 
ventilation openings. 
 

 

Please note! 
For proper functioning, the outlet must at 
least be 0,5m away from: 
 

 

Corners of the building; 

 

Roof overhangs and balconies; 

 

Roof edges (with the exception of the 
ridge edge, see chapter 15). 
 

C11, outlet via facade 
Through a wall or façade, use a Faber wall outlet. 
Depending on the flue calculation this can be 
100/150mm or 130/200mm. 
 
C31, outlet via roof 
For a (flat) roof, use a Faber roof outlet with a 
diameter of 100/150mm. 
 
C91, existing chimney 
For an existing chimney, use a Faber chimney 
outlet with a diameter of 100/150mm. 
In this case the existing chimney acts as air inlet an 
inserted flexible stainless steel pipe discharges the 
flue gas. The top (Faber chimney cover plate) and 
the bottom (Faber chimney connection set) should 
be airtight. 
Depending on the calculated flue diameter, you 
must use a flexible stainless steel pipe of 
Ø100mm (article number AJ005503) or Ø130mm 
(article number AJ005603) as specified by Faber. 
For this, contact Glen Dimplex Benelux B.V. 
 

 

Please note! 

 

The minimum chimney diameter for a 
130mm flexible stainless steel pipe must 
be 200x200mm and for a 100mm flexible 
stainless steel pipe and 150x150mm. 

 

Don’t connect more than one fire at the 
existing chimney. 

 

The chimney must be in good condition: 

o

 

No leakage; 

o

 

Well cleaned. 

 

For more information about the connections to 
existing chimney ducts, please request the 
installation instructions “Chimney Connection Set”. 

4

 

Preparation and installation 
instructions 

 

4.1

 

Gas connection 

The gas connection must comply with the 
applicable local standards.  
 

 

Please note! 

 

Provide a flexible gas connection with at 
least 0,5m extra length, so that the 
control unit can be removed for 
installation and service! 

 

Calculate the gas pipe so that no 
pressure drop occurs. 

Summary of Contents for Concept III

Page 1: ...Installation manual Triple M Smart Triple L Smart ENG 40011605 2003 ...

Page 2: ...Installation manual Triple M L Smart 1 ...

Page 3: ...Installation manual Triple M L Smart 2 ...

Page 4: ...Installation manual Triple M L Smart 3 1 0 1 1 1 2 1 3a 1 3b ...

Page 5: ...Installation manual Triple M L Smart 4 1 4 1 5 1 6 1 7 1 8 Y X ...

Page 6: ...Installation manual Triple M L Smart 5 2 0a 2 0b 2 0c 2 1 3 0 3 1 3 2 4 0 A B A Q R S T E E B ...

Page 7: ...Installation manual Triple M L Smart 6 4 1 4 2 4 3 4 4 ...

Page 8: ...Installation manual Triple M L Smart 7 ...

Page 9: ... note It is advisable to always install a screen for the fireplace if children elderly or disabled people are present in the same room as the fireplace If regularly vulnerable persons can be present in the room without supervision sufficient protection must always be placed around the fireplace This appliance must be installed according with the rules in force and used only in a sufficiently space...

Page 10: ...rify that the desired outlet meets the local regulations regarding pollution and ventilation openings Please note For proper functioning the outlet must at least be 0 5m away from Corners of the building Roof overhangs and balconies Roof edges with the exception of the ridge edge see chapter 15 C11 outlet via facade Through a wall or façade use a Faber wall outlet Depending on the flue calculation...

Page 11: ...attachment 17 5 or 17 6 4 6 Installing the flue pipes Install the flue pipes according to the installation manual supplied with the appliance 40011968 The distance to combustible materials must be min 50mm calculated from the outside of the flue pipe Never start immediately with length adjustable concentric flue pipe on the appliance Horizontal sections should be installed to allow a slope towards...

Page 12: ...d be 4mm higher as point E see fig 2 1 Perform the steps of Method II Placing the cover strips insert strip Place the horizontal cover strip Q fig 3 0 or the horizontal insert strip R fig 3 1 Place the vertical cover strips S fig 3 2 these are held in place by adjustable magnets The insert strip R can be removed by the supplied magnet T see fig 3 1 5 Removing glass 5 1 Front glass Remove the horiz...

Page 13: ...ure Turn measuring nipple B see fig 1 1 some turns open and connect a measuring hose to the gas valve The pressure must correspond to the value indicated in the technical specifications of this manual In case of deviation contact the manufacturer Please note Close both pressure measuring nipples and check for gas leakage Check ignition and burner Ignite the fireplace by using the remote control as...

Page 14: ...ribed in chapter 7 For an extensive maintenance instruction maintenance protocol gas fires see 10 Conversion to other gas type This can only be done by replacing the burner To do so please contact your dealer Always provide the type and serial number of the appliance when ordering 11 Flue calculation A simple way to calculate whether the exhaust configuration is possible in combination with your f...

Page 15: ... vertical fig 12 2 and 12 3 G O and S Elbows 45 or 30 vertical to horizontal plane These are 30 or 45 elbows vertically offset less than 45 fig 12 1 B and D Pipes at an angle of inclination These are pipes vertically ascending at an angle of 30 or 45 fig 12 1 C Fill in only in combination with at least two 30 or 45 elbows in the vertical part Restrictor table See restrictor table for the correct v...

Page 16: ...00 50 00 40 00 40 00 30 00 x x x x 12 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x 13 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x 14 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x 15 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x 16 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x 17 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x 18 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x ...

Page 17: ...00 50 00 40 00 30 00 x x x x 12 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x 13 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x 14 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x 15 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x 16 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x 17 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x 18 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x ...

Page 18: ...Installation manual Triple M L Smart 17 12 Examples flue materials ...

Page 19: ...5 Flue length 2m or more 2 Bend 90 0 1 Bend 45 30 or 15 0 2 Roof terminal 1 Wall terminal 0 Total Vertical Height TVH measured height rounded value meter meter Total Horizontal Length THL Calculation Part number x value result rounded value Total Length in meters x 1 90 Bend vertical to horizontal x 0 4 45 Bend vertical to horizontal x 0 2 90 Bend in horizontal direction x 1 5 45 Bend in horizonta...

Page 20: ...installation is not possible Solution Change the TVH or THL Results Restrictor size Value for the comma mm Extra information Value behind the comma mark Install the air restrictor plate see installation manual 0 1 Install adapter 100 150 direct on top of the fire 0 2 In case of wall terminal install adapter 100 150 before the last bend in case of roof terminal just before the terminal 0 3 In case ...

Page 21: ...ergy efficiency index EEI 87 87 87 Type heating output control room temperature no no no no yes no Glen Dimplex Benelux Saturnus 8 Heerenveen The Netherlands With mechanical control of the room temperature by thermostat Control of room temperature with open window detection no With electronic control of the room temperature With electronic control of the room temperature plus day time switch With ...

Page 22: ... B Energy efficiency index EEI 86 86 86 Type heating output control room temperature no no no no yes no Diameter outlet inlet 100 150 Technical data Type indication s Triple Smart L Type appliance C11 C31 C91 Gas connection 3 8 Indirect heating functionality no Category II2H3 Gas rate at full mark Power requirement for permanent pilot light if applicable Ppilot 0 15 0 15 kW Other control options O...

Page 23: ...ition outlet Distance mm D Under a gutter 500 E Under a roof edge 500 F Under a carport or balcony 500 G Vertical downpipe 300 H Inside and outside corners 500 J From wall surface to a wall outlet 1000 K Two gable outlets against over each other 1000 L Distance between two roof outlets 450 M Two roof outlets above each other on a pitched roof 1000 N Two gable outlets next to each other 1000 Short ...

Page 24: ...Installation manual Triple M L Smart 23 16 Troubleshooting guide ...

Page 25: ...Installation manual Triple M L Smart 24 ...

Page 26: ...Installation manual Triple M L Smart 25 17 Dimensional drawings 17 1 Triple M Smart with cover strip ...

Page 27: ...Installation manual Triple M L Smart 26 17 2 Triple M Smart with insert strip ...

Page 28: ...Installation manual Triple M L Smart 27 17 3 Triple L Smart with cover strip ...

Page 29: ...Installation manual Triple M L Smart 28 17 4 Triple L Smart with insert strip m L ...

Page 30: ...Installation manual Triple M L Smart 29 17 5 Wall bracket Triple M Smart article number A9322596 ...

Page 31: ...Installation manual Triple M L Smart 30 17 6 Wall bracket Triple L Smart article number A9322696 ...

Page 32: ...Installation manual Triple M L Smart 31 17 7 Remote access door article number A9299463 ...

Page 33: ...Installation manual Triple M L Smart 32 17 8 Ventilation grid article number A9296400 ...

Page 34: ...Installation manual Triple M L Smart 33 17 9 Adjustable feet article number A9319696 ...

Page 35: ...Installation manual Triple M L Smart 34 18 Decoration instruction card 18 1 Log set Triple M Smart ...

Page 36: ...Installation manual Triple M L Smart 35 18 2 Log set Triple L Smart ...

Page 37: ...Installation manual Triple M L Smart 36 ...

Page 38: ...Installation manual Triple M L Smart 37 ...

Page 39: ...Installation manual Triple M L Smart 38 ...

Page 40: ...www faberfires com contact faberfires com Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen ...

Reviews: