Faber CLASSICA PLUS CLAS30SS300-B Installation Instructions Manual Download Page 3

3

ALL  WALL  AND  FLOOR  OPENINGS  WHERE  THE  RANGEHOOD  IS  INSTALLED  MUST  

BE  SEALED.

This rangehood requires at least 24" of clearance

 between the bottom of the rangehood 

and the cooking surface or countertop. This hood has been approved by UL at this distance from 

the cooktop. 

This minimum clearance may be higher depending on local building codes. For gas cooktops and 

combination ranges, a minimum of 30" is recommended and may be required.

Overhead cabinets on both sides of this unit must be a minimum of 18" above the cooking surface 

or countertop. Consult the cooktop or range installation instructions given by the manufacturer 

before making any cutouts. 

MOBILE HOME INSTALLATION The installation of this rangehood must conform to the Manufactured 

Home Construction and Safety Standards, Title 24 CFR, Part 3280 (formerly Federal Standard 

for Mobile Home Construction and Safety, Title 24, HUD, Part 280). See Electrical Requirements.

• Venting system MUST terminate outside the home.

• 

DO NOT

 terminate the ductwork in an attic or other enclosed space.

• 

DO NOT

 use 4" laundry-type wall caps.

• Flexible-type ductwork is not recommended.

• 

DO NOT

 obstruct the flow of combustion and ventilation air.

• Failure to follow venting requirements may result in a  fire.

   WARNING

!

Cold Weather installations

An additional back draft damper should be installed to minimize backward cold air flow and a 

nonmetallic thermal break should be installed to minimize conduction of outside temperatures as 

part of the vent system. The damper should be on the cold air side of the thermal break. The break 

should be as close as possible to where the vent system enters the heated portion of the house.

VENTING   REQUIREMENTS

Determine which venting method is best for your application.  Ductwork can extend either through the 

wall or the roof.

The length of the ductwork and the number of elbows should be kept to a minimum to provide efficient 

performance.  The size of the ductwork should be uniform.  Do not install two elbows together.  Use 

duct tape to seal all joints in the ductwork system.  Use caulking to seal exterior wall or floor opening 

around the cap.

Flexible ductwork is not recommended.  Flexible ductwork creates back pressure and air turbulence 

that greatly reduces performance.

Make sure there is proper clearance within the wall or floor for exhaust duct before making cutouts.  

Do not cut a joist or stud unless absolutely necessary.  If a joist or stud must be cut, then a supporting 

frame must be constructed. 

WARNING - To Reduce The Risk Of Fire, Use Only Metal Ductwork.

CAUTION - To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do 

not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages. 

3.  When cutting or drilling into wall or ceiling, do not damage electrical wiring and 

other hidden utilities.

4.  Ducted fans must always be vented to the outdoors.

Summary of Contents for CLASSICA PLUS CLAS30SS300-B

Page 1: ...CLAS30SS600 B CLAS36SS600 B CLAS30SS300 B CLAS36SS300 B Installation Instructions Use and Care Information Instructions d installation Utilisez et d entretien CLASSICA PLUS...

Page 2: ...with your back to an exit Based on Kitchen Firesafety Tips published by NFPA WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK do not use this fan with any solid state speed control device WARNING...

Page 3: ...ackward cold air flow and a nonmetallic thermal break should be installed to minimize conduction of outside temperatures as part of the vent system The damper should be on the cold air side of the the...

Page 4: ...or grounding circuit could result in electrical shock Check with a qualified electrician if you are in doubt as to whether the rangehood is properly grounded Failure to follow electrical requirements...

Page 5: ...5 RANGEHOOD DIMENSIONS 0 1 0 Min 30 Min 24...

Page 6: ...ssories Direct Connect Wiring Box sku number WIREBOX Activated Charcoal Filter sku FILTER1 Activated Charcoal Filter sku FILTER1LL High Ceiling Chimney Kit Upper and Lower Chimney Flue to replace the...

Page 7: ...culation Option Ducted Venting Options Installation Requires purchase of Activated Charcoal Accessory Horizontal Vertical 6 H I Install Damper that is included with the Hood before connecting to the d...

Page 8: ...a bracket 7 2 1 on the wall as shown about 1 1 8 from the ceiling or upper limit aligning the centers notch withtheverticalreferencelineandmarkthewallatthecentersoftheholesinthebracket Place the seco...

Page 9: ...ugs purchase separately Insert not completely the two screws 12a supplied in the hood body fixing holes as shown Hook the hood body onto the screws and screw completely From inside the Hood body mark...

Page 10: ...er purchased separately onto the hood body air outlet 12 Fix the bracket 7 2 1 using the screws 12a supplied 11 Slightly widen the two sides of the lower section and hook them between the upper secti...

Page 11: ...undinginstructions are not completely understood or if doubt exists as to whether the appliance is properly grounded Do not use an extension cord If the power supply cord is too short have a qualified...

Page 12: ...imed to run for 10 minutes At the end of this time it will automatically return to the speed set before Suitable to deal with maximum levels of cooking fumes If you hold this button down for 2 seconds...

Page 13: ...ownward Wash the filter without bending it leave it to dry thoroughly before replacing if the surface of the filter changes color over time this will have absolutely no effect on its efficiency Replac...

Page 14: ...14 Wiring Diagram...

Page 15: ...om accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical or plumbing codes or Faber documentation or use of products not approved...

Page 16: ...nevoiedesortiesetrouvederri revouspendantquevous teignezlesflammes D apr sleguide KitchenFiresafetyTips publi parlaNFPAaux tats Unis AVERTISSEMENT POURR DUIRELERISQUED INCENDIEOUDECHOC LECTRIQUE n uti...

Page 17: ...on pourrait entra ner un incendie AVERTISSEMENT Installation dans les climats froids Le syst me de ventilation doit pr voir un registre antirefoulement suppl mentaire pour r duire le flux d air froid...

Page 18: ...sible dans le circuit neutre ou de mise la terre peut entra ner un choc lectrique Consultez un lectricien qualifi si vous n tes pas certain de la mise la terre de la hotte Le non respect des exigences...

Page 19: ...19 0 1 0 DIMENSIONS DE LA HOTTE Min 30 Min 24...

Page 20: ...cte no d article WIREBOX No d article Filtre charbon actif FILTER1 No d article Filtre charbon actif FILTER1LL Trousse de chemin e pour plafonds hauts Conduit de chemin e sup rieur et inf rieur pour r...

Page 21: ...rder aux conduits Pour installation avec ventilation canalis e uniquement Choisissez la m thode de canalisation Sans canalisation Option de recirculation Options d installation avec ventilation canali...

Page 22: ...z une bride 7 2 1 sur le mur comme illustr environ 1 1 8 du plafond ou de la limite sup rieure en alignant les centres encoche avec la ligne de r f rence verticale Marquez l emplacement du centre des...

Page 23: ...partiellement les deux vis 12a fournies dans les trous de fixation du b ti de la hotte comme illustr Engagez le b ti de la hotte sur les vis et vissez les compl tement l int rieur du b ti de la hotte...

Page 24: ...puis raccordez les conduits Installation avec canalisation verticale ou horizontale Option non canalis e avec recirculation d air cartez l g rement les deux c t s de la chemin e sup ri eure et engagez...

Page 25: ...outes quant la mise la terre de l appareil N utilisez pas de rallonge Si le cordon d alimentation est trop court demandez un lectricien qualifi d installer une prise proximit de l appareil INSTALLATIO...

Page 26: ...pour une dur e de 10 minutes Apr s ce d lai la vitesse retournera automatiquement la vitesse s lectionn e pr c demment Utile pour contrer les manations maximales de cuisson Si vous tenez ce bouton enf...

Page 27: ...zlefiltresansleplier Laissez les cher compl tement avant de le r installer un changement de la couleur la surface du filtre au fil du temps n a aucun impact sur son efficacit Remettez leenplace envous...

Page 28: ...28 Sch ma de c blage...

Page 29: ...es d coulant d un accident d une modification de l utilisation incorrecte ou abusive d un incendie d une inondation d un cas de force majeure d une installation inad quate d une installation non confo...

Page 30: ...30...

Page 31: ...31...

Page 32: ...991 0381 585_08 181116 D00001448_07...