Faber CLASSICA PLUS CLAS30SS300-B Installation Instructions Manual Download Page 15

15

January 4, 2016 

FABER CONSUMER WARRANTY & SERVICE  

All Faber products are warranted against any defect in materials or workmanship for the original purchaser 
for a period of 1 year from the date of original purchase (requires proof of purchase).  This warranty covers 
labor and replacement parts.  Faber, at its option, may repair or replace the product or components 
necessary to restore the product to good working condition.  To obtain warranty service, contact the dealer 
from whom you purchased the range hood, or the local Faber distributor. If you cannot identify a local Faber 
distributor, contact us at (508) 358-5353 for the name of a distributor in your area. 

The following is not covered by Faber's warranty: 

1. Service calls to correct the installation of your range hood, to instruct you how to use your range hood, to 
replace or repair house fuses or to correct house wiring or plumbing. 
2. Service calls to repair or replace range hood light bulbs, fuses or filters. Those consumable parts are 
excluded from warranty coverage. 
3. Repairs when your range hood is used for other than normal, single-family household use. 
4. Damage resulting from accident, alteration, misuse, abuse, fire, flood, acts of God, improper installation, 
installation not in accordance with electrical or plumbing codes or Faber documentation, or use of products 
not approved by Faber. 
5. Replacement parts or repair labor costs for units operated outside the United States or Canada, including 
any non-UL or C-UL approved Faber range hoods. 
6. Repairs to the hood resulting from unauthorized modifications made to the range hood. 
7. Expenses for travel and transportation for product service in remote locations and pickup and delivery 
charges. Faber range hoods should be serviced in the home. 

THIS WARRANTY DOES NOT ALLOW RECOVERY OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, WITHOUT 
LIMITATION, DIRECT, INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES, PERSONAL INJURY/WRONGFUL 
DEATH OR LOST PROFITS FABER  WARRANTY IS LIMITED TO THE ABOVE CONDITIONS AND TO THE WARRANTY PERIOD 
SPECIFIED HEREIN AND IS EXCLUSIVE. EXCEPT AS EXPRESSLY SPECIFIED IN THIS AGREEMENT, FABER DISCLAIMS ALL 
EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS, AND WARRANTIES INCLUDING, WITHOUT LIMITATION, ANY 
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE

.

This warranty gives you specific legal rights that may vary from state to state. 

Model#: ______________________________                  Serial #: _____________________________ 

Summary of Contents for CLASSICA PLUS CLAS30SS300-B

Page 1: ...CLAS30SS600 B CLAS36SS600 B CLAS30SS300 B CLAS36SS300 B Installation Instructions Use and Care Information Instructions d installation Utilisez et d entretien CLASSICA PLUS...

Page 2: ...with your back to an exit Based on Kitchen Firesafety Tips published by NFPA WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK do not use this fan with any solid state speed control device WARNING...

Page 3: ...ackward cold air flow and a nonmetallic thermal break should be installed to minimize conduction of outside temperatures as part of the vent system The damper should be on the cold air side of the the...

Page 4: ...or grounding circuit could result in electrical shock Check with a qualified electrician if you are in doubt as to whether the rangehood is properly grounded Failure to follow electrical requirements...

Page 5: ...5 RANGEHOOD DIMENSIONS 0 1 0 Min 30 Min 24...

Page 6: ...ssories Direct Connect Wiring Box sku number WIREBOX Activated Charcoal Filter sku FILTER1 Activated Charcoal Filter sku FILTER1LL High Ceiling Chimney Kit Upper and Lower Chimney Flue to replace the...

Page 7: ...culation Option Ducted Venting Options Installation Requires purchase of Activated Charcoal Accessory Horizontal Vertical 6 H I Install Damper that is included with the Hood before connecting to the d...

Page 8: ...a bracket 7 2 1 on the wall as shown about 1 1 8 from the ceiling or upper limit aligning the centers notch withtheverticalreferencelineandmarkthewallatthecentersoftheholesinthebracket Place the seco...

Page 9: ...ugs purchase separately Insert not completely the two screws 12a supplied in the hood body fixing holes as shown Hook the hood body onto the screws and screw completely From inside the Hood body mark...

Page 10: ...er purchased separately onto the hood body air outlet 12 Fix the bracket 7 2 1 using the screws 12a supplied 11 Slightly widen the two sides of the lower section and hook them between the upper secti...

Page 11: ...undinginstructions are not completely understood or if doubt exists as to whether the appliance is properly grounded Do not use an extension cord If the power supply cord is too short have a qualified...

Page 12: ...imed to run for 10 minutes At the end of this time it will automatically return to the speed set before Suitable to deal with maximum levels of cooking fumes If you hold this button down for 2 seconds...

Page 13: ...ownward Wash the filter without bending it leave it to dry thoroughly before replacing if the surface of the filter changes color over time this will have absolutely no effect on its efficiency Replac...

Page 14: ...14 Wiring Diagram...

Page 15: ...om accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical or plumbing codes or Faber documentation or use of products not approved...

Page 16: ...nevoiedesortiesetrouvederri revouspendantquevous teignezlesflammes D apr sleguide KitchenFiresafetyTips publi parlaNFPAaux tats Unis AVERTISSEMENT POURR DUIRELERISQUED INCENDIEOUDECHOC LECTRIQUE n uti...

Page 17: ...on pourrait entra ner un incendie AVERTISSEMENT Installation dans les climats froids Le syst me de ventilation doit pr voir un registre antirefoulement suppl mentaire pour r duire le flux d air froid...

Page 18: ...sible dans le circuit neutre ou de mise la terre peut entra ner un choc lectrique Consultez un lectricien qualifi si vous n tes pas certain de la mise la terre de la hotte Le non respect des exigences...

Page 19: ...19 0 1 0 DIMENSIONS DE LA HOTTE Min 30 Min 24...

Page 20: ...cte no d article WIREBOX No d article Filtre charbon actif FILTER1 No d article Filtre charbon actif FILTER1LL Trousse de chemin e pour plafonds hauts Conduit de chemin e sup rieur et inf rieur pour r...

Page 21: ...rder aux conduits Pour installation avec ventilation canalis e uniquement Choisissez la m thode de canalisation Sans canalisation Option de recirculation Options d installation avec ventilation canali...

Page 22: ...z une bride 7 2 1 sur le mur comme illustr environ 1 1 8 du plafond ou de la limite sup rieure en alignant les centres encoche avec la ligne de r f rence verticale Marquez l emplacement du centre des...

Page 23: ...partiellement les deux vis 12a fournies dans les trous de fixation du b ti de la hotte comme illustr Engagez le b ti de la hotte sur les vis et vissez les compl tement l int rieur du b ti de la hotte...

Page 24: ...puis raccordez les conduits Installation avec canalisation verticale ou horizontale Option non canalis e avec recirculation d air cartez l g rement les deux c t s de la chemin e sup ri eure et engagez...

Page 25: ...outes quant la mise la terre de l appareil N utilisez pas de rallonge Si le cordon d alimentation est trop court demandez un lectricien qualifi d installer une prise proximit de l appareil INSTALLATIO...

Page 26: ...pour une dur e de 10 minutes Apr s ce d lai la vitesse retournera automatiquement la vitesse s lectionn e pr c demment Utile pour contrer les manations maximales de cuisson Si vous tenez ce bouton enf...

Page 27: ...zlefiltresansleplier Laissez les cher compl tement avant de le r installer un changement de la couleur la surface du filtre au fil du temps n a aucun impact sur son efficacit Remettez leenplace envous...

Page 28: ...28 Sch ma de c blage...

Page 29: ...es d coulant d un accident d une modification de l utilisation incorrecte ou abusive d un incendie d une inondation d un cas de force majeure d une installation inad quate d une installation non confo...

Page 30: ...30...

Page 31: ...31...

Page 32: ...991 0381 585_08 181116 D00001448_07...