Builders opening (mm)
Feeling
Silence
Whisper
Spectra
Cadra
Misty
Nova
Nova
A Opening width*
960
960
780
780
680
710
B Opening height*
649
649
705
698
798
890
C Opening depth*
385
385
430
430
430
370
Shelf dimensions
(combustible)
D Min. height shelf from
top frame
350
350
350
350
350
350
E Depth shelf max.
150
150
150
150
150
150
Dimensions (mm)
F
Box width
880
880
750
750
650
698
G Box depth
366
366
397
375
375
338
H Box height
636
636
714
715
815
879
I
Frame width
1064
1064
815
794
694
740
J
Frame height
678
678
720
703
803
905
K Frame thickness
47
20
16
30
30
144
L
Position flue
(behind frame)255
255
257
235
235
196
M Position flue (from the
back side box)111
111
140
140
140
142
UK/IRL
7
UK/IRL
6
3.1 Builders opening and surround (continuing)
If the builders' opening is constructed out of non-combustible
composition board (Fibrelux) and you install the appliance without a
mantel then:
- Ventilate the space above the appliance (min. 1000 mm
2
).
- Always fit the DC convection set.
- The plaster of the outside has to be resistant to a high
temperature. Use therefore the plaster materials especially made for
this, to prevent discoloring (min. 100 °C temperature resistant).
If the appliance is to be fitted against a wall with combustible
cladding, the cladding must be removed from the area covered by the
surround.
The minimum height from the top surface of the fire to the underside
of any shelf made from wood or other combustible materials is as
follows:
- For a shelf up to 150 mm deep – Minimum height = 350 mm
(fig. 1).
- If the shelf depth is greater than 150 mm add 50 mm to the upper-
clearance height for every 25 mm increase in shelf depth.
- Side clearance = Minimum distance from the side of the fire frame
to combustible material = 150 mm.
fig. 1
table 1
*the points A until C applies a tolerance from:
– 0 mm and + 5 mm.