19 <
<
<
<
UK
IRL
Appendix D: Technical specifications Flatburner
Flatburner
Flatburner
Country
UK / IRL
UK / IRL
Cat
II 2E+3+
II 2H3+
Appliance type
C11 of C31
C11 of C31
Reference gas
G20
G31
Input (Nett)
kW
8.7
8.3
Efficiency class
2
2
Inlet pressure
Mbar
20
37
Gas rate*
l/h
917
330
Gas rate*
gram/h
620
Working pressure (high)
Mbar
11.0
32.4
Injector size
Mm
Bray 800
Bray 280
Reduced input restraint
Mm
2.10
1.10
Pilot assembly
SIT 145
SIT 145
Code
Nr.36
Nr.23
Flue system
Flue size
Mm
100-150
100-150
Std. Flue restrictor
Mm
30
30
Gas control
GV 60
C4E3M6M
C4D3M6M
Gas connection
Nut/olive
8 mm
8 mm
* at 15ºC and 1013 mbar