Dear user 

Congratulations on your purchase of a Faber fire! A 
quality product from which you will experience 
warmth and atmosphere for many years. We 
recommend that you read this manual carefully 
before using the fireplace. If any problem arises 
despite our strict quality control, you can always 
contact your dealer or Glen Dimplex Benelux B.V. 

 

For any warranty claims, it is essential you first 
register your fireplace. During this registration, 
you’ll find all information regarding our warranty. 
 

 

Please note! 
The details of your fireplace can be found in 
the user manual. 

 
You can register your fire at: 

www.faberfires.com

 

 
Glen Dimplex Benelux B.V. 
Address:  Saturnus 8 
 

 NL-8448 CC 
 Heerenveen 

Tel: 

+31 (0)513 656 500  

Email:  [email protected] 
Info: 

www.faberfires.com 

 

1.1

 

Introduction 

Installation and maintenance of the appliance must 
be carried out by a professional with proven 
knowledge and competence. A professional takes 
into account all technical aspects such as heat 
radiation and gas connection as well as flue gas 
exhaust requirements. 
 
Where the installation instructions are not clear, 
national/local regulations must be followed. 
 

1.2

 

Check 

Check the fireplace for transport damage and 
immediately report any damage to your supplier. 
 

1.3

 

CE Declaration 

We hereby declare that Glen Dimplex Benelux B.V. 
released Faber gas-atmosphere heating appliance 
by its design and construction method complies 
with the Regulation (EU): 2016/426 and (EU) 
2015/1188. 
 
Product: gas room heater 
Model:  Blokhus 
 
This declaration will become null and void as soon 
as the unit is in any way modified without written 
authorization of Glen Dimplex Benelux B.V. 
 
 

2

 

Safety instructions 

 

 

Please note! 

It is advisable to always install a screen for the 
fireplace if children, elderly or disabled people are 
present in the same room as the fireplace. If 
regularly vulnerable persons can be present in the 
room without supervision, sufficient protection 
must always be placed around the fireplace. 

 

This appliance must be installed according 
with the rules in force and used only in a 
sufficiently space. 

 

The appliance must be checked annually 
in accordance with this installation 
manual and the applicable national and 
local regulations. 

 

Ensure that the data on the type label 
matches the local gas type and pressure. 

 

The appliance is designed for atmosphere 
and heating purposes. This means that all 
visible surfaces, including the glass, can 
become hotter than 100°C. An exception 
by free standing models is the underside 
of the fireplace and the control buttons. 

 

Do not use the remote control and / or 
app outside the room where the fire is 
located. So that you are always aware of 
the situation around the fireplace when it 
is being operated.  

 

The settings and the construction of the 
fireplace must not be changed! 

 

Do not place extra imitation wood or 
other material on the burner or in the 
combustion chamber. 

 

Do not place any combustible materials 
within 0,5m of the radiation area of the 
fire. 

 

Through the natural air circulation of the 
fireplace moisture and uncured volatile 
components from paint, building 
materials and carpeted floors, etc. are 
attracted. These parts can settle as soot 
on cold surfaces. Therefore do not light 
the fireplace shortly after installation. 

 

2.1

 

Using the fire for the first time 

Provide extra ventilation and open all the windows 
of the room during the initial start-up of the fire. 
Let the fire burn at the highest setting for a few 
hours so that the paint gets the chance to harden 
and any released vapours are safely removed. Keep 
vulnerable people and pets out of this room during 
this process. 

 

Summary of Contents for Blokhus

Page 1: ...Installation manual Blokhus Extension modules HE module ENG 40011609 2012 ...

Page 2: ...Installation manual Blokhus Extension modules HE module 1 ...

Page 3: ...Installation manual Blokhus Extension modules HE module 2 ...

Page 4: ...Installation manual Blokhus Extension modules HE module 3 1 0 1 1 1 2 1 3 1 4 1 5 1 6 A B C ...

Page 5: ...Installation manual Blokhus Extension modules HE module 4 1 7 1 8a 1 8b ...

Page 6: ...Installation manual Blokhus Extension modules HE module 5 1 9 2 0 2 1 2 2 2 3 2 4 F ...

Page 7: ...note It is advisable to always install a screen for the fireplace if children elderly or disabled people are present in the same room as the fireplace If regularly vulnerable persons can be present in the room without supervision sufficient protection must always be placed around the fireplace This appliance must be installed according with the rules in force and used only in a sufficiently space ...

Page 8: ...hrough a wall or façade use a Faber wall outlet Depending on the flue calculation this can be 100 150mm or 130 200mm C31 outlet via roof For a flat roof use a Faber roof outlet with a diameter of 100 150mm C91 existing chimney For an existing chimney use a Faber chimney outlet with a diameter of 100 150mm In this case the existing chimney acts as air inlet an inserted flexible stainless steel pipe...

Page 9: ...eady loose This is the access for the gas control unit 4 5 Positioning the fireplace Take into account the installation requirements see chapter 3 Place the fireplace at the right place and level it Please note The fireplace can be levelled with the 4 adjustable feet in the bottom plate see fig 1 6 C Use an Allen key 5 for this A wall bracket is supplied as standard with the appliance see fig 1 9 ...

Page 10: ... to the tube burners and rest on the bottom of the fire Remove the glass granulate and vermiculite granules underneath these logs Divide the ash material between the logs don t cover the air intake the perforated parts at the back Please note Keep the pilot flame free from glass granulate and ash material Start the fireplace as described in the user manual Assess whether the flame distribution and...

Page 11: ... advice and instructions on care and cleaning of the glass Emphasize the danger of fingerprint burns at the glass Handover to customer o installation manual o user manual o decoration instruction card o suction cups o sample Faber glass polish 9 Annual maintenance Check Check and clean if necessary the combustion chamber the burner the pilot flame the wooden logs for breakage the glass es the outl...

Page 12: ...lbows and pipes entirely in the horizontal plane See elbows I K and Q and the elements H J L M P and R fig 12 1 and 12 2 Horizontal length The Horizontal Length consists of the elements H J L M P and R fig 12 1 and 12 2 Elbows 90 in the horizontal plane Horizontal elbows are elbows entirely in the horizontal plane fig 12 1 12 2 and 12 3 I K and Q Elbows 45 or 30 in the horizontal plane Horizontal ...

Page 13: ...Installation manual Blokhus Extension modules HE module 12 11 1 Restrictor table 100 150 Blokhus without HE module Start length STL Vertical TVH and Horizontal THL ...

Page 14: ...Installation manual Blokhus Extension modules HE module 13 11 2 Restrictor table 100 150 Blokhus with HE module Start length STL Vertical TVH and Horizontal THL ...

Page 15: ...Installation manual Blokhus Extension modules HE module 14 12 Examples flue materials ...

Page 16: ...till 2m 1 5 Flue length 2m or more 2 Bend 90 0 1 Bend 45 30 or 15 0 2 Roof terminal 1 Wall terminal 0 Total Vertical Height TVH measured height rounded value meter meter Total Horizontal Length THL Calculation Part number x value result rounded value Total Length in meters x 1 90 Bend vertical to horizontal x 0 4 45 Bend vertical to horizontal x 0 2 90 Bend in horizontal direction x 1 5 45 Bend in...

Page 17: ... then the installation is not possible Solution Change the TVH or THL Results Restrictor size Value for the comma mm Extra information Value behind the comma mark Install the air restrictor plate see installation manual 0 1 Install adapter 100 150 direct on top of the fire 0 2 In case of wall terminal install adapter 100 150 before the last bend in case of roof terminal just before the terminal 0 ...

Page 18: ...cy class A A A Energy efficiency index EEI 89 89 89 Type heating output control room temperature no no no no yes no Glen Dimplex Benelux Saturnus 8 Heerenveen The Netherlands With mechanical control of the room temperature by thermostat Control of room temperature with open window detection no With electronic control of the room temperature With electronic control of the room temperature plus day ...

Page 19: ...cation Position outlet Distance mm D Under a gutter 500 E Under a roof edge 500 F Under a carport or balcony 500 G Vertical downpipe 300 H Inside and outside corners 500 J From wall surface to a wall outlet 1000 K Two gable outlets against over each other 1000 L Distance between two roof outlets 450 M Two roof outlets above each other on a pitched roof 1000 N Two gable outlets next to each other 1...

Page 20: ...Installation manual Blokhus Extension modules HE module 19 16 Troubleshooting guide ...

Page 21: ...Installation manual Blokhus Extension modules HE module 20 ...

Page 22: ...Installation manual Blokhus Extension modules HE module 21 17 Dimensional drawings 17 1 Blokhus ...

Page 23: ...Installation manual Blokhus Extension modules HE module 22 17 2 Position gas connection ...

Page 24: ...Installation manual Blokhus Extension modules HE module 23 18 Decoration instruction card ...

Page 25: ...Installation manual Blokhus Extension modules HE module 24 ...

Page 26: ...Installation manual Blokhus Extension modules HE module 25 ...

Page 27: ...Installation manual Blokhus Extension modules HE module 26 19 Instruction extension modules and HE module ...

Page 28: ...Installation manual Blokhus Extension modules HE module 27 1 0 2 0 3 0 4 0 ...

Page 29: ...ion modules these must be placed on the top module Extension module s Loosen screws A on the inside to remove the panels from the extension modules fig 1 0 If necessary the back panel s can be removed by loosening screws B fig 1 0 Remove the upper panel of the fire by loosening screws A fig 1 0 Installation instructions HE module Before mounting the extension module s place the HE module first fig...

Page 30: ...Installation manual Blokhus Extension modules HE module 29 20 Dimensional drawings 20 1 Extension module single article number A9319796 20 2 Extension module double article number A9319896 ...

Page 31: ...Installation manual Blokhus Extension modules HE module 30 20 3 Wall bracket ...

Page 32: ...Installation manual Blokhus Extension modules HE module 31 20 4 Blokhus with HE module extension module double ...

Page 33: ...Installation manual Blokhus Extension modules HE module 32 20 5 HE module article number A9319996 ...

Page 34: ...Installation manual Blokhus Extension modules HE module 33 ...

Page 35: ...Installation manual Blokhus Extension modules HE module 34 ...

Page 36: ...www faberfires com contact faberfires com Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen ...

Reviews: