background image

UK/IRL

 

26

 

<

 

 

3)

 

Assemble the flue system onto the firebox (see chapter 5). 

4)

 

Check if applicable that the safety hatch seals the combustion 
chamber properly. Do not fasten it at all! If you fasten it, this 
explosion safety hatch won’t function properly! 

5)

 

 If necessary, place the DC convection system (also consult the 
instruction belonging to the DC construction set).  

6)

 

If necessary, isolate the firebox with a ceramic blanket (25 mm). 
Preferred choice for insulation is unbound insulation wool (at 1000 °C 
gives no smell). 

Fig.16: Safety hatch 

Fig.17 

Summary of Contents for BF80S

Page 1: ...PURE BF80S SILENCE FEELING SENSE WHISPER SPECTRA NOVA CADRA NOVA MISTY Room sealed built in gas fireplace with Log Burner Technology Installation guide and user manual 40010556 39 04 ...

Page 2: ...UK IRL 2 ...

Page 3: ...l 29 6 2 Connection onto an existing chimney 29 6 3 Remote control 31 6 3 1 Installation remote control 32 6 3 2 Setting the right transmission code 32 7 Commisioning functional checks 33 7 1 Check pilot ignition 33 7 2 Functional burner check 33 7 3 Functional balanced flue check 34 7 4 Check reference pressure and burner pressure 34 8 Final check and handing over 36 9 Servicing Fout Bladwijzer n...

Page 4: ...UK IRL 4 10 4 2 Setting the right transmission code 51 10 4 3 Changing the batteries 52 11 Cleaning and service instructions 53 12 Disposal of packaging and appliance 54 ...

Page 5: ...r Types and Cadra Nova Special features Realistic flame and glow effect because of the Log burner technology Room sealed appliance inlet and outlet are led to the outside using a natural draught concentric pipe system 100 mm 150 mm no power fan required No additional ventilation required Air supply and flue gases go to outside atmosphere through wall or roof A maximum horizontal extension of 6 met...

Page 6: ...de and injector must be exchanged complete for a pilot assembly from the original manufacturer only Ventilation This appliance is room sealed and doesn t require purpose provided ventilation 3 1 General safety It is the law in the UK that all gas appliances are installed by a competent person in accordance with the Gas Safety Installation and Use Regulations as amended the relevant British Standar...

Page 7: ...with IS813 ICP3 IS327 Building Regulations Codes of Practice the manufacturers instructions and any other rules in force Failure to comply with the above could leave the installer liable to prosecution and invalidate the appliance warranty Safety instructions for the user see chapter 9 ...

Page 8: ...stalled in the following situations In a non combustible fireplace or builders opening This could be either an existing builders opening or a new made prefab builders opening For the measurements see figure 1 and index Although the appliance is tested for installation without a hearth the appliance must not stand on combustible materials or carpets If the appliance is placed on a combustible floor...

Page 9: ...appliance mm F Box width 880 880 880 750 750 750 650 698 G Box depth 369 366 369 397 397 375 375 338 H Box height 636 636 636 714 714 715 815 879 I Frame width 1064 1136 1064 795 815 794 694 740 J Frame height 678 750 678 795 720 703 803 905 K Frame thickness 47 57 20 35 16 30 30 144 L Position flue collar measured from frame 255 255 255 255 257 235 235 196 M Position flue collar measured from bac...

Page 10: ... the surround The minimum height from the top surface of the fire to the underside of any shelf made from wood or other combustible materials is as follows For a shelf up to 150 mm deep Minimum height 350 mm fig 1 If the shelf depth is greater than 150 mm add 50 mm to the upperclearance height for every 25 mm increase in shelf depth Side clearance Minimum distance from the side of the fire frame t...

Page 11: ...are not to be counted à the wall mounted terminal counts for 1 meter Flue restrictor If applicable in the table is also stated the size of a flue restrictor This restrictor needs to be fitted in the combustion chamber when placing the appliance see chapter 4 2 Normally the smallest flue restrictor is fitted Example calculation 1 Calculating horizontal extension fig 2a Flue lenght C E 1m 1m 2 m Elb...

Page 12: ... the Widescreen table nr 2 Combination not allowed When calculating on basis of the MV100 table nr 3 Allowed but without flue restrictor Remove the flue restrictor When calculating on basis of the MV150 table nr 4 Combination not allowed When calculating on basis of the Roundscreen table nr 5 Combination not allowed 4 3 Tables for determining the right flue restrictor Calculate the total horizonta...

Page 13: ... 0 0 0 0 5 50 50 45 45 30 0 0 6 50 50 45 45 30 0 0 7 60 60 60 50 50 45 X 8 60 60 60 60 50 X X 9 65 65 60 60 X X X 10 65 65 65 X X X X 11 65 65 X X X X X 12 65 X X X X X X Table 2 Widescreen Feeling Silence Sense Vertical length in m Table 3 MV200 Pure BF80S Spectra Nova Whisper Horizontal length in m Vertical length in m The numbers in the table represent the width in mm of the flue restrictor X C...

Page 14: ...0 0 0 0 0 0 4 50 40 40 30 0 0 0 5 50 50 40 40 30 30 0 6 50 50 50 40 40 30 0 7 60 50 50 40 40 40 X 8 60 60 50 50 50 X X 9 60 60 60 50 X X X 10 65 60 60 X X X X 11 65 65 X X X X X 12 65 X X X X X X Tabel 4 binnenwerk MV150 Cadra Nova Vertical length in m Tabel 5 binnenwerk Roundscreen Misty Vertical length in m Horizontal length in m Horizontal length in m The numbers in the table represent the widt...

Page 15: ...inted out to the customer before installation If in any doubt about flue location advice should be sought from local building control or if appliancerelated from the manufacturer including wherever possible a dimensioned sketch Avoid locating the terminal in close proximity to plastic materials such as gutters or other combustibles If this is unavoidable then a suitable deflector should be made So...

Page 16: ...mm F Below balconies or cat port roof 600 mm G From a vertical drain pipe or soil pipe 300 mm H Dfrom an internal or external corner 600 mm I Above ground roof or balcony level 300 mm J From a surface facing the terminal 600 mm K From a terminal facing a terminal 600 mm L From an opening in the carport e g window into the dwelling 1200 mm M Vertically from a terminal on the same wall 1500 mm N Hor...

Page 17: ...upply must only service this appliance A chimney that has previously been used for solid fuel must be swept before use The existing chimney needs to be airtight The existing chimney needs to have an opening of min 150 x 150 mm The chimney needs to be intact and well looked after Use the adjustable roof mounted terminal especially made for this and the chimney connection set The minimum distance be...

Page 18: ...g 4 The connection should be made in 8 mm copper or similar semi flexible tube max 1 meter Ensure that the gas pipe does not interfere with the removal or replacement of the burner tray of the controls 5 The gas connection is nut and olive suitable for 8 mm pipe 5 2 Preparing the appliances Before you can install the appliance properly it is wise to prepare the appliance because you still have acc...

Page 19: ...ft side for the Whisper Remove the frame by loosening the screws A behind the door see fig 5 Lift and pull forward when you take it away 2 Remove the back panel by loosening the screws B see fig 6 3 Remove the glass by removing the glass clamps C see fig 7 for instance with a screwdriver Careful when removing the glass Wear gloves Before placing the glass back be sure that there are no fingerprint...

Page 20: ...chamber To determine the right flue restrictor see paragraph 4 2 and 4 3 Attention y If possible first install the appliance before building up the false chimney breast y If possible install the the appliance before installing the flue If this is not possible a slidable piece of pipe should be used as a connection Fig 5 Fig ...

Page 21: ...wdriver Careful when removing the glass Wear gloves Before placing the glass back be sure that there are no fingerprints on the glass it is not possible to remove them when they are burnt in 3 Take the box with the log set out of the combustion chamber 4 Place the right flue restrictor in the combustion chamber To determine the right flue restrictor see paragraph 4 2 and 4 3 Fig 8 Fig 7 ...

Page 22: ...is not possible a slidable piece of pipe should be used as connection y Leave a gap between the frame and wall to ease the lifting and removal of the frame How this is done is described in paragraph 5 3 5 2 6 Preparing the Misty 1 Remove the door frame Lift and pull forward see fig 10 2 Remove the outher frame by removing screws B See fig 11 and taking away the frame Fig 10 Fig 11 ...

Page 23: ... there are no fingerprints on the glass It is not possible to remove those prints once they are burned in the glass 4 Take the box with the log set out of the combustion chamber 5 Like in the previous models place the right flue restrictor in the combustion chamber see fig 13 To determine the right flue restrictor see paragraph 4 2 and 4 3 Fig 12 Fig 13 ...

Page 24: ...e of pipe should be used as connection 5 2 7 Preparing the Spectra Nova and Cadra Nova 1 To open the door remove the screws A see fig 14 Open and remove the door lift and pull forward Be sure that there are no fingerprints on the glass It is not possible to remove those prints once they are burned in the glass 2 Remove the outher frame by removing screws B See fig 15 and taking away the frame A A ...

Page 25: ...all the the appliance before installing the flue If this is not possible a slidable piece of pipe should be used as connection 5 3 Placing the appliance Points of attention for placement If possible first locate the appliance before assembling the flue If this is not possible then always use an extendible pipe before connection onto the appliance 1 Position the firebox in the fireplace opening You...

Page 26: ...it at all If you fasten it this explosion safety hatch won t function properly 5 If necessary place the DC convection system also consult the instruction belonging to the DC construction set 6 If necessary isolate the firebox with a ceramic blanket 25 mm Preferred choice for insulation is unbound insulation wool at 1000 C gives no smell Fig 16 Safety hatch Fig 17 ...

Page 27: ...e outher frame with 4 screws 11 Misty and Widescreen Mount the inner frame by lifting it in its supports Secure the frame of the Widescreen by fastening the inner frame with 2 screws 12 Pure Adjust the position of the frame support by unscrewing two bolts on either side on the inside of the top of the appliance see fig 18 and 19 Then slide the support in position and fasten the bolts again Do the ...

Page 28: ... the burner tray 2 dimples placed in the middle over he burner and resting on the burner tray 3 dimples the right side log placed over the burner and resting on the burner tray Attention Make sure there are no embers between the logs and the burner tray Make sure the logs are placed on the burners in the right way Fig 20 Log set Widescreen Fig 21 Log set Spectra Nova Whisper Fig 22 Log set Cadra N...

Page 29: ...se of expansion or cooling down the concentric pipes can turn loose It is recommended to fix the spring clip with a self tapping screw at inaccessible places 7 To get the exact measure flue length you can use cut downconcentric pipe wall mounted terminal or roof mounted terminal To obtain a smoke sealed connection the inner pipe must be 20 mm longer then the outside pipe 8 The horizontal pipes nee...

Page 30: ... part number A 9273900 Fig 19 part E and F 1 Place the aluminium closure plate A onto the chimney Permanently attach and make airtight 2 Pull the liner C through the chimney 3 Connect the liner onto the roof terminal and fix this with the clamp provided with the chimney connection set 4 Place the roof terminal onto the closure plate 5 Fixing the chimney sealing plate D and place the 150 mm grommet...

Page 31: ...lames it functions only when the pilot burner is ignited It is therefore not possible to ignited the appliance with the remote control or to shut off the pilotflame The radio frequency remote control is intended for fireplaces installed in a domestic setting in all EU countries except Austria Denmark Finland and Greece Features Manual control will always remain possible The remote control is a rad...

Page 32: ...ransmitter which is already done at the factory However the code disappears if the receiver is disconnected from the mains for a longer period 1 Push the mod button on the receiver and hold it for 3 seconds 2 The green control lamp will light up and stay on Repeat this step if it doesn t 3 Push a button on the remote control The control lamp on the receiver should now go out 4 Again push a button ...

Page 33: ...tinue to hold in the control knob for a further ten seconds to ensure that the pilot flame is stable 4 Release the knob The pilot should remain alight 7 2 Functional burner check 1 Turn knob B to max clockwise 2 Turn the knob A more anticlockwise to the position large flame Now it is possible to light the main burner 3 Turn knob B anticlockwise to max The main burner should light Check for gas sou...

Page 34: ...up Check the If the correct flue restrictor is installed 7 4 Check reference pressure and burner pressure The appliance is preset to give the correct heat input No further adjustment is necessary Fit a pressure gauge at the burner pressure test point D to check the burner pressure The pressure should be checked with the appliance alight and at max input The setting pressure should be as shown at t...

Page 35: ...e pressure is too low check if the gas pipes are made of material wit the right diameter 6 When the pressure is too high more than 5 mBar you can t install the appliance and you should contact your gas company 7 Always check the burner pressure when the functional pressure is right You can measure the burner pressure by using sensor D The pressure should match the prescribed pressure If this is no...

Page 36: ...he appliance including the glass Instruct the customer on the operation of the remote control including the replacement of batteries and how to set the right transmissions code Hand over these instructions including the user guide to the consumer Recommend that the appliance should be serviced by a competent person at least once a year ...

Page 37: ...ion chamber the glass 2 Check the log lay and replace the embers if applicable 3 Do the functional test as described at page 34 4 Check the flue system and terminal on damage and soundness visual inspection 9 1 1 Cleaning the glass Depending on the intensity of use you can get a deposit on the glass Normally this can be removed with an ordinary dry towel If necessary special ceramic glass cleaner ...

Page 38: ...eaner 3 Place back the logs as described in paragraph 4 6 If the burner is visibly damaged this can affect the distribution of the flame If so then replace the burner 9 1 3 Burner tray dis assembly 1 Break the gas supply at the control valve 2 Remove the glass the log set grid and burner tray cover 3 Detach the gas connection at the 8 mm nut and olive 4 Unscrew the burner assembly and take them ou...

Page 39: ...reversed order 9 2 Propane conversion For conversion from propane to natural gas you have to order a complete new propane burner unit Contact your supplier and give the serial number from the data plate when you order 9 3 Combustion tests A BS7967 combustion analysis check should be carried out using an analyser to BS7927 positioned in the flue outlet A Ratio of CO CO2 should be less than 0 01 wit...

Page 40: ...control 20603900 20603900 20603900 20603900 20603900 20603900 20603900 Adapter 20900142 20900142 20900142 20900142 20900142 20900142 20900142 Motor remote control 37003086 37003086 37003086 37003086 37003086 37003086 37003086 Spark wire 06014500 06017300 06014500 06014500 06014500 06014500 06014500 Spark electrode x 06006600 x x x x x Oxypilot 37001042 x 37001042 37001042 37001042 37001042 3700104...

Page 41: ...gram Reference burner pressure mbar 17 22 Injector size mm 3x1 45 and 1x1 3 3 x 1 00 Reduced input restrictor mm 1 8 1 1 Pilot assembly Type SIT 160 SIT 160 code Nr 51 Nr 30 Flue system MV size 100 150 100 150 Preinstalled flue restrictor mm 30 30 Gas control GV36 C5AOEHC68M GV36 C5AODHC68M Remote control Voltage adapter V 4 5 4 5 Batteries remote control 2x LR03 1 5V Alkaline 2x LR03 1 5V Alkalin...

Page 42: ...C en 1013 mbar 540 gram Setting pressure mbar 17 22 Injector size mm 2x1 40 1x1 30 3 x 1 00 Reduced input restrictor mm 1 8 1 1 Pilot assembly Type SIT 160 SIT 160 code Nr 51 Nr 30 Flue system MV size 100 150 100 150 Preinstalled flue restrictor mm 30 30 Gas control GV36 C5AOEHC68M GV36 C5AODHC68M Remote control Voltage adapter V 4 5 4 5 Batteries remote control 2x LR03 1 5V Alkaline 2x LR03 1 5V ...

Page 43: ...13 mbar 540 gram Setting pressure mbar 13 25 Injector size mm 3x1 50 3 x 0 90 Reduced input restrictor mm 1 8 1 1 Pilot assembly Type SIT 160 SIT 160 code Nr 51 Nr 30 Flue system MV size 100 150 100 150 Preinstalled flue restrictor mm 30 30 Gas control GV36 C5AOEHC68M GV36 C5AODHC68M Remote control Voltage adapter V 4 5 4 5 Batteries remote control 2x LR03 1 5V Alkaline 2x LR03 1 5V Alkaline Gas c...

Page 44: ...13 mbar 540 gram Setting pressure mbar 16 25 Injector size mm 3x1 50 3 x 0 95 Reduced input restrictor mm 1 8 1 1 Pilot assembly Type SIT 160 SIT 160 code Nr 51 Nr 30 Flue system MV size 100 150 100 150 Preinstalled flue restrictor mm 30 30 Gas control GV36 C5AOEHC68M GV36 C5AODHC68M Remote control Voltage adapter V 4 5 4 5 Batteries remote control 2x LR03 1 5V Alkaline 2x LR03 1 5V Alkaline Gas c...

Page 45: ...UK IRL 45 User guide ...

Page 46: ...UK IRL 46 ...

Page 47: ...on again Contact a qualified installer when the appliance goes off regularly The appliance has been designed for heating purposes This means that all surfaces including the glass can become very warm over 100 C An exception to this is the lower side of the door and the control buttons Due to the newness of materials they may give off a slight smell for a period after initial lighting This is norma...

Page 48: ...d standards Note Since the appliance is a source of heat circulation of air occurs Therefore it is of importance that you do not use the appliance shortly after a renovation of the home Because of the natural circulation of air moist and volatile components from paint building materials carpet etc will be attracted These components can settle themselves down onto cold surfaces in the form of soot ...

Page 49: ...e first function is to turn on the gas to the pilot this occurs just before reaching the position if the fire has not been lit for some time it may be necessary to hold the knob in this position for some seconds to clear the air from the pipe and allow gas to reach the pilot burner Once gas is available at the pilot continued rotation anti clockwise will cause the piezo igniter to spark This is ac...

Page 50: ...the pilot flame is stable 3 Release the knob The pilot should remain alight 4 Turn the control knob A to the position 5 Turn knob B slowly anticlockwise the fire should then ignite 6 Adjust flames to the required level 11 3 To extinguish 1 For the main burner turn the control knob B clockwise to position 2 To disable knob B turn knob A to the position 3 To extinguish the pilot turn control knob A ...

Page 51: ...emote control is easy to install retrospectively 11 4 1 Using the remote control 1 Light the appliance as described in 10 2 2 Set the on off switch on the receiver to on and control the flames Low flame High flame 3 Use high and low to achieve the desired heating and flame effect 4 You will hear a beep every time the receiver recognises a signal If not see 10 4 3 setting the right transmission cod...

Page 52: ...1 year depending on the frequency of use There is no risk of electric shock as the low voltage supply is similar to that used in torches Always turn off the appliance before changing batteries Remote control 1 Remove the cover on the back of the remote control 2 Carefully remove the battery clip along the side Pay attention not to pull the wires 3 If necessary remove the old batteries and place th...

Page 53: ...he trim wipe with soft damp cloth only Do not use abrasive cleaners polish or solvents as these can damage the surface finish Cleaning the glass To remove the glass to clean it follow the steps described in paragraph 4 5 To clean the glass follow the steps and suggestions described in paragrapg 8 1 1 Be sure that there are no fingerprints on the glass It is not possible to remove those prints afte...

Page 54: ...s These materials should be disposed responsibly and in conformity with government regulations Batteries are considered chemical waste The batteries should be disposed of responsibly and in conformity with government regulations Remove the batteries before disposing of the remote control Information on how to responsibly dispose of discarded appliances can be obtained from the local authorities ...

Page 55: ...UK IRL 55 ...

Page 56: ...UK IRL 56 Saturnus 8 NL 8448 CC Heerenveen P O Box 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 ...

Reviews: