Faber Aspect L ST Installation Manual Download Page 5

                                                                                                                                              

4 < 

<

 

<

 

<

 

L   

  

1

 

Introduction 

The appliance can only be installed by a 

competent person in accordance with the Gas 
Safety. We urgently advise you to read this 

installation manual properly. 
This appliance complies with the guidelines 

for European gas appliances (Gas Appliances 
Directive) and bears the CE mark. 

 

2

 

 Safety instructions. 

 

The appliance should be placed, 
connected and annually checked in 

accordance with these installation 
instructions and valid national and 

local Gas Safety (Installation and Use) 
Regulations . 

 

Check whether the data on the 
registration plate are in agreement 

with the local type of domestic gas 
and pressure.  

 

The fitter is not permitted to change 
these adjustments or the construction 

of the appliance! 

 

Do not place any additional imitation 
logs or glowing coals on the burner or 

in the combustion chamber. 

 

The appliance has been designed for 

ambience and heating purposes. This 
means that all surfaces of the 

appliance , including the glass, can 
become very hot (hotter than 100 

°C). An exception to this are the 
bottom  of the appliance and the 

controls. 

 

Do not  place any inflammable 

materials within a of  0.5 m. of the 
radiation of the appliance and 

ventilation grills.  

 

Due to natural air circulation of the 
appliance, moisture and volatile 

components from paint, building 
materials, floor coverings etc. that 

haven’t yet set, can be drawn through 
the convection system and can be 

deposited on cold surfaces as soot. 
That is why you should not use the 

appliance shortly after a renovation.   

 

The first time the appliance is 

switched on, Let the fire run on 
maximum setting for several hours so 

that the lacquer coating will have an 
opportunity to set and possible 

vapours released can be safely 
removed by ventilation. We advise 
you to be  outside the room as much 

as possible during this process! 

 

Please note that: 

 

all transport packaging should be 
removed.  

 

children or pets should not be 
present in the room. 

 

3

 

Installation requirements 

 

3.1

 

The fire  

 

The appliance must be built into an 
existing or a newly to be constructed 

false chimney breast. 

 

In appliances with flexible gas pipes, 

the gas control valve is mounted to 
the right side of the fire for safe 

transport . Unscrew it and mount it at 
a distance of max. 30  cm behind the 

access door. 

 

The receiver which has been attached 
in a transport holder (see fig. 1.4 A) 

to the side of control valve bracket, 
can now be slid onto the top of the 

control valve bracket. The transport 
holder can be removed now. 

3.2

 

False Chimney breast 

 

The false chimney breast must be 

constructed of an non-combustible 
material. 

 

Always ventilate the space above the 
appliance by means of the grills or a 

comparable alternative with a 
minimum air supply of 200 cm². 

 

For the finish, use special stucco 
(min. 100°C resistant) or glass fibre 
wallpaper to prevent discoloration or 

cracks etc. Recommended drying 
time: for plaster is a minimum of 24 

hours per mm of coat applied. 

 

The false chimney breast and its 

construction may not rest on the 
appliance  

 

3.3

 

 Requirements flue system and 

outlets 

 

You should always make use of the 

materials prescribed by Faber 
International Ltd. Only by using these 

materials can Faber International Ltd. 
guarantee a proper functioning. 

 

The outside of the concentric flue 

material can reach a temperature of  

 

Approx 150°C. Make sure of proper 

isulation and protection in case of 
transit through combustible wall or 

Summary of Contents for Aspect L ST

Page 1: ...Aspect L ST 40010936 1021 Installation manual ENG ENG ...

Page 2: ...L 1 1 1 1 2 1 3 1 4 1 5 A ...

Page 3: ...L 2 2 1 2 2 2 3 2 4 2 5 2 6 2 7 ...

Page 4: ...L 3 3 1 3 2 3 3 ...

Page 5: ...several hours so that the lacquer coating will have an opportunity to set and possible vapours released can be safely removed by ventilation We advise you to be outside the room as much as possible during this process Please note that all transport packaging should be removed children or pets should not be present in the room 3 Installation requirements 3 1 The fire The appliance must be built int...

Page 6: ...ppliance are not damaged Clear a safe space to store the frame and the glass Remove the frame if necessary and the glass and take the separately wrapped parts out of the appliance Prepare the gas connection to the gas control valve 4 4 Placing the appliance Take the installation requirements into account see chapter 3 Place the appliance into the proper position and if necessary adjust the height ...

Page 7: ...ed from the burner plate but it should be level throughout the entire length Place the imitation logs according to instructions see fig 3 1 or the instruction card It is optional whether you apply chips to the combustion chamber or not Prevent chips from covering the burner this has a negative effect on the fire image Start the pilot en main burner according to the instructions in the user s manua...

Page 8: ... client Recommend that the appliance be serviced annually by a competent person in order to guarantee a safe use and a long lifespan Advise and instruct the client about maintenance and cleaning of the glass Emphasize the risk of burning in fingerprints Instruct the client about the operation of the appliance and the remote control unit including the replacement of the batteries and adjusting the ...

Page 9: ... vice versa are not reckoned in the calculation The wall terminal always counts as 1 metre If there is transit under 45 then the real vertical and horizontal lengths should be calculated 11 1 Points of particular interest In case of a wall terminal the entire flue system including the wall terminal should be constructed of 200 130 flue pipes In case of a roof terminal the entire flue system should...

Page 10: ... D 1 x 2 m 2 m Total 4 m Count the vertical lengths Flue pipe length A 1 m Roof terminal G 1 m Total 2 m Sample calculation 2 Count the horizontal lengths Flue pipe lengths J L 0 5 0 5 1 m Bends K M 2 2 m 4 m Wall terminal 1 m Total horizontal length 6 m Count the vertical lengths Flue pipe length H 1 m Total 1m ...

Page 11: ...nstallation than the fire most install with the 150 100 mm flue pipe Horizontaal m 0 1 2 3 4 5 6 7 8 9 10 0 x 0 x x x x x x x x x 0 5 x 0 0 0 0 x x x x x x 1 x 30 0 0 0 0 0 0 0 0 0 1 5 30 50 50 40 40 30 30 30 0 0 0 2 30 60 60 50 50 40 40 30 30 0 0 3 40 65 65 60 60 50 50 40 40 30 x 4 40 70 70 65 65 60 50 50 40 x x 5 50 70 70 70 65 65 60 50 x x x 6 55 75 75 65 65 60 60 x x x x 7 60 75 75 75 65 65 x ...

Page 12: ... h 780 750 Burner pressure at full mark mbar 9 5 23 5 24 5 Injector main burner mm ST500 7x0 79 ST510 7x0 83 ST160 7x0 48 ST180 7x0 50 ST160 7x0 48 ST180 7x0 50 Reduced input restraint mm 2 1 1 3 1 3 Pilot assembly Sit145 Sit145 Sit145 Code Nr 36 Nr 23 N 23 Diameter inlet outlet mm 200 130 200 130 200 130 Gas control valve GV60 GV60 GV60 Gas connection 3 8 3 8 3 8 Electrical connection V 220 220 2...

Page 13: ...L 12 14 Dimentions ...

Page 14: ...L 13 ...

Page 15: ...14 L ...

Page 16: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 ...