4 <
<
<
<
L
1
Introduction
The appliance can only be installed by a
competent person in accordance with the Gas
Safety. We urgently advise you to read this
installation manual properly.
This appliance complies with the guidelines
for European gas appliances (Gas Appliances
Directive) and bears the CE mark.
2
Safety instructions.
The appliance should be placed,
connected and annually checked in
accordance with these installation
instructions and valid national and
local Gas Safety (Installation and Use)
Regulations .
Check whether the data on the
registration plate are in agreement
with the local type of domestic gas
and pressure.
The fitter is not permitted to change
these adjustments or the construction
of the appliance!
Do not place any additional imitation
logs or glowing coals on the burner or
in the combustion chamber.
The appliance has been designed for
ambience and heating purposes. This
means that all surfaces of the
appliance , including the glass, can
become very hot (hotter than 100
°C). An exception to this are the
bottom of the appliance and the
controls.
Do not place any inflammable
materials within a of 0.5 m. of the
radiation of the appliance and
ventilation grills.
Due to natural air circulation of the
appliance, moisture and volatile
components from paint, building
materials, floor coverings etc. that
haven’t yet set, can be drawn through
the convection system and can be
deposited on cold surfaces as soot.
That is why you should not use the
appliance shortly after a renovation.
The first time the appliance is
switched on, Let the fire run on
maximum setting for several hours so
that the lacquer coating will have an
opportunity to set and possible
vapours released can be safely
removed by ventilation. We advise
you to be outside the room as much
as possible during this process!
Please note that:
all transport packaging should be
removed.
children or pets should not be
present in the room.
3
Installation requirements
3.1
The fire
The appliance must be built into an
existing or a newly to be constructed
false chimney breast.
In appliances with flexible gas pipes,
the gas control valve is mounted to
the right side of the fire for safe
transport . Unscrew it and mount it at
a distance of max. 30 cm behind the
access door.
The receiver which has been attached
in a transport holder (see fig. 1.4 A)
to the side of control valve bracket,
can now be slid onto the top of the
control valve bracket. The transport
holder can be removed now.
3.2
False Chimney breast
The false chimney breast must be
constructed of an non-combustible
material.
Always ventilate the space above the
appliance by means of the grills or a
comparable alternative with a
minimum air supply of 200 cm².
For the finish, use special stucco
(min. 100°C resistant) or glass fibre
wallpaper to prevent discoloration or
cracks etc. Recommended drying
time: for plaster is a minimum of 24
hours per mm of coat applied.
The false chimney breast and its
construction may not rest on the
appliance
3.3
Requirements flue system and
outlets
You should always make use of the
materials prescribed by Faber
International Ltd. Only by using these
materials can Faber International Ltd.
guarantee a proper functioning.
The outside of the concentric flue
material can reach a temperature of
Approx 150°C. Make sure of proper
isulation and protection in case of
transit through combustible wall or
Summary of Contents for Aspect L ST
Page 1: ...Aspect L ST 40010936 1021 Installation manual ENG ENG ...
Page 2: ...L 1 1 1 1 2 1 3 1 4 1 5 A ...
Page 3: ...L 2 2 1 2 2 2 3 2 4 2 5 2 6 2 7 ...
Page 4: ...L 3 3 1 3 2 3 3 ...
Page 13: ...L 12 14 Dimentions ...
Page 14: ...L 13 ...
Page 15: ...14 L ...