Find the correct vertical and horizontal
lengths in the table.
In case of an “x”, or if the values are outside
the table, the combination is not permitted.
The value found indicates the width of the
restrictor to be placed ("0" means no
restrictor should be placed).
Generally a 30mm restrictor is pre-installed.
12.1
Please note : only a vertical flue
installation,
than the fire most install with the 150/100
mm flue pipe.
Horizontaal (m)
*0 1 2 3 4 5 6 7 8 9 10
0
x 0 x x x x x x x x x
0.5
x 0 0 0 0 x x x x x x
1
x 30 0 0 0 0 0 0 0 0 0
1.5
*30 50 50 40 40 30 30 30 0 0 0
2
*30 60 60 50 50 40 40 30 30 0 0
3
*40 65 65 60 60 50 50 40 40 30 x
4
*40 70 70 65 65 60 50 50 40 x x
5
*50 70 70 70 65 65 60 50 x x x
6
*55 75 75 65 65 60 60 x x x x
7
*60 75 75 75 65 65 x x x x x
8
*60 75 75 75 65 x x x x x x
9
*75
80 80 75 x x x x x x x
10
*75
80 80 x x x x x x x x
11
*80
80 x x x x x x x x x
Verticaal
12
*80 x x x x x x x x x x