background image

Version 3/08 - Page 5

PREPARE  THE  CABINET

1. 

Disconnect and move freestanding range from cabinet 

opening to provide easier access to upper cabinet and rear 

wall.  Put a thick, protective covering over cooktop, set-in 

range or countertop to protect from damage or dirt.

2. 

Determine and clearly mark with a pencil the center line 

of the cabinet on the wall and on the underside of the cabinet 

where the rangehood will be installed.

3. 

The Agio attaches to the cabinet by four black screws.  

Mark the cabinet and insert the screws into the underside 

of the cabinet as shown in  

FIGURE  8

.  Do not tighten the 

screws.

INSTALL  THE  RANGEHOOD

1. 

Remove the unit from the carton and place on a flat 

surface for assembly.  Make sure to cover the surface to 

prevent accidental damage.  Remove all parts including the 

Backdraft Damper, Screws, and Literature Package before 

discarding the carton.

2. 

Remove both grease filters from the unit and set aside.  

The rangehood is shipped from the factory with the backdraft 

damper attached inside.  Using a Phillips head screwdriver, 

remove the backdraft damper by loosening the screw marked 

with a red dot on top of the rangehood.

3. 

Before installing, the rangehood must be adjusted for 

venting.  For ductless installations, read the following section 

which discusses special requirements for these installations 

before continuing.  

For  Horizontal  or  Vertical  ducting,  the  respective  exhaust 

knockout must be removed.  Each knockout is attached to the 

rangehood by four points.  Using a flat blade screwdriver or 

utility knife, remove the exhaust knockout.  Save this plate as 

it must be used to block the ductless exhaust grill.  

FIGURE 

10

 shows the location of the knockouts for both horizontal 

and vertical.  ONLY ONE must be removed.

30" or 36" or 23 5/8" (60 cm)

30" or 36" or 23 5/8" (60 cm)

30" or 36" or 23 5/8" (60 cm)

FIGURE  7

FIGURE  9

FIGURE  8

4. 

Determine the proper cutouts for the ductwork.  Make 

all necessary cuts in the walls or cabinets for the ductwork.  

Install the ductwork before mounting the rangehood.

5. 

Determine the proper location for the Power Supply 

Cable.  Both possible locations are given in 

FIGURE 9

.  Use 

a 1  1/4" Drill Bit to make this hole.  Run the Power Supply 

Cable.  Use caulking to seal around the hole.  DO NOT turn 

on the power until installation is complete.

Summary of Contents for AGIO

Page 1: ... sans surveillance à la puissance de chauffage maximale un renversement débordement de matière graisseuse pourrait provoquer une inflammation et le génération de fumée Utiliser toujours une puissance de chauffage moyenne ou basse pour le chauffage d huile b Veiller à toujours faire fonctionner le ventilateur de la hotte lors d une cuisson avec une puissance de chauffage élevée ou lors de la cuisso...

Page 2: ...ical connection cut a 1 1 4 hole in the wall A hole cut through wood must be sanded until smooth A hole through metal must have a grommet WARNING TOREDUCETHERISKOFFIREORELECTRIC SHOCK do not use this fan with any solid state speed control device WARNING TO REDUCE THE RISK OF FIRE ELECTRI CAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Use this unit only in the manner intended by the manufactu...

Page 3: ...un rendement maximal en ce qui a trait à la combustionainsiqu àl évacuationdesgazparlaconduite de cheminée une bonne aération est nécessaire pour tous les appareils à combustion Suivez les conseils et mesuresdesécuritédufournisseurtelsqueceuxpubliés par l Association Nationale de la Sauvegarde contre l Incendie et l Association Américaine d Ingénieurs de Chauffage Frigorifaction et Air Climatisé a...

Page 4: ...ucted with the required minimum of 3 1 4 by 10 rectangular duct Calculate the length of the ductwork by adding the equivalent feet in FIGURE 4 foreachpieceofductinthesystem AnexampleisgiveninFIGURE 5 For best results use no more than three 90 elbows Make sure that there is a minimum of 24 of straight duct between elbows if more than one is used Do not install two elbows together If you must elbow ...

Page 5: ...crewdriver remove the backdraft damper by loosening the screw marked with a red dot on top of the rangehood 3 Before installing the rangehood must be adjusted for venting For ductless installations read the following section which discusses special requirements for these installations before continuing For Horizontal or Vertical ducting the respective exhaust knockout must be removed Each knockout...

Page 6: ...operation 5 Attach the cover behind the exhaust grate with two silver screws supplied with the rangehood as indicated in FIGURE 12 11 Replace the field wiring compartment cover For duct less installations refer to the next section which discusses ductless installations Replace the grease filters 12 Turn the power supply on Turn on blower and light IF THE RANGEHOOD DOES NOT OPERATE Check that the c...

Page 7: ...n turns the blower on HIGH Operation Indicator Light I Red light will be on when the rangehood is operating Microswitch MS When the front panel of the rangehood is closed the rangehood will turn off by a microswitch This turns the rangehood On and Off without adjusting the switches for the Light or Blower and it remembers the last speed setting Cleaning The metal grease filters should be cleaned f...

Page 8: ...umbing 2 Service calls to repair or replace range hood light bulbs fuses or filters Those consumable parts are excluded from warranty coverage 3 Repairs when your range hood is used for other than normal single family household use 4 Damage resulting from accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical or plumbing codes o...

Page 9: ... horizontal pour cette hotte La figure 3 montre l ouverture d échappement pour l installation sans conduit calcul de longueur du conduit La longueur du conduit ne doit jamais excéder 25 pi s il s agit de conduit rectangulaire de 3 1 4 po Calculer la longueur du conduit en ajoutant l équivalent en pied de la FIGURE 4 pour chaque pièce du conduit du système Un exemple est donné à la FIGURE 5 Pour de...

Page 10: ...a hotte 1 Retirer l appareil de la boîte et le déposer sur une surface plate pour l assemblage Couvrir la surface pour éviter tout dommage accidentel Retirer toutes les pièces incluant 1 registre à clapet les vis et le nécessaire d instructions avant de jeter la boîte 2 Retirer les deux filtres pour la graisse de l appareil et les mettre de côté La hotte est expédiée de l usine avec un registre de...

Page 11: ... Mettre en circuit le ven tilateur et la lumière Si la hotte ne fonctionne pas Vérifier si le disjoncteur n est pas hors tension ou si un fusible n est pas grillé Débrancher l alimentation et vérifier si les connexions ont été faites de façon adéquate installations sans conduit Les installations sans conduit requièrent le nécessaire sans conduit Le ventilateur doit être placé de façon à ce que l é...

Page 12: ...rcuit ON et hors circuit OFF sans ajustement des interrupteurs de la lumière ou du ventilateur et la hotte se rappellera du dernier réglage de vitesse Nettoyage Les filtres à graisse en métal devraient être nettoyés fré quemment dans une solution d eau chaude et de détergent ou mettre au lave vaisselle Nettoyer les surfaces extérieu res à l eau chaude savonneuse Ne pas utiliser de produits abrasif...

Page 13: ... maison ou pour corriger votre câblage ou votre système de plomberie 2 Les appels de service pour remplacer ou réparer les ampoules les fusibles ou les filtres de votre hotte de cuisinière 3 Les réparations lorsque votre hotte de cuisinière a été utilisée plus que la normale c est à dire plus que pour une famille par foyer 4 Les dommages résultant d un accident de l altération d une mal utilisatio...

Reviews: