Faber 280 CFM Use And Care Manual Download Page 9

Version 03/08- Page 9

Rangehood Control Panel

The control panel is located in the middle under the canopy.  The 

position and function of each control button are noted below 

(FIG

-

URE 13A FOR 3-SPEED 500 CFM MODELS, FIGURE 13B FOR 

2-SPEED 280 CFM MODELS)

.

Light On/Off Button ( L )

On/Off switch for the halogen lights.    Move the switch to "1" to turn 

the light ON and to "0" to turn it OFF.

Blower On/Off Button  ( M )

On/Off switch for the blower.    Move the switch to "1" to turn the 

blower ON and to "0" to turn it OFF.

 

Blower Speed Button ( V )

Speed  control  for  blower.   

FOR  3-SPEED  500  CFM  MODELS 

(FIGURE  13A), 

move  the  switch  to"1"  for  LOW  speed,  "2"  for 

MEDIUM speed and "3" for HIGH speed.  

FOR 2-SPEED 280 CFM 

MODELS (FIGURE 13B),

 move the switch to"1" for LOW speed 

and "2" for HIGH speed.

WIRING  DIAGRAM FOR 

3-SPEED 500 CFM MODEL

DIAGRAMME DE CÂBLAGE MOD

È

LE 3 VITESSE 500 PCM

• This rangehood uses 20 watt Halogen Lamps. / Cette hotte utilise les ampoule halogènes de 20 W.

WIRING  DIAGRAM FOR 

2-SPEED 280 CFM MODEL

DIAGRAMME DE CÂBLAGE MOD

È

LE 2 VITESSE 280 PCM 

CONTROL PANELS AND WIRING DIAGRAMS

The Synthesis rangehood is available in two versions: a 3-speed 500 

cfm version and a 2-speed 280 cfm version.  Please check the speed 

control under the canopy to note which version you own.  The 3-speed 

500 cfm version, will have options of speeds 1, 2, and 3.  The 2-speed 

280 cfm version, will only have options of speeds 1 and 2.

FIGURE  13A - 3-SPEED 500 CFM / 

3 VITESSE 500 PCM

FIGURE  13B - 2-SPEED 280 CFM / 

2 VITESSE 280 PCM

PANNEAU DE COMMANDES & DIAGRAMMES DE CÂBLAGE

Le Synthesis est disponible dans deux versions : une version du 

3 vitesse 500 pcm et une version du 2 vitesse 280 pcm. Veuillez 

vérifier la commande de vitesse sous la hotte pour noter quelle 

version vous possédez. La version du 3 vitesse 500 pcm, aura des 

options des vitesses 1, 2, et 3. La version du 2 vitesse 280 pcm, 

aura seulement des options des vitesses 1 et 2.

Panneau de commandes

Le panneau de commandes est situé sur le moyen sous la hotte. 

La position et la fonction de chaque bouton sont indiquées à la 

FIGURE 13

 

(FIGURE 13A POUR MODÈLES 3-VITESSE 500 PCM, 

FIGURE 13B POUR MODÈLES 2-VITESSE 280 PCM).

Bouton marche-arrêt de la lumière (L)

Interrupteur marche-arrêt pour la lumière. Régler à « 1 » pour mettre 

en circuit (ON) et à « 0 » pour mettre hors circuit (OFF).

Bouton marche-arrêt du ventilateur (M)

Interrupteur marche-arrêt pour le ventilateur. Régler à « 1 » pour 

mettre en circuit (ON) et à « 0 » pour mettre hors circuit (OFF).

Bouton de vitesse du ventilateur (V)

Commande de vitesse variable. 

POUR MODÈLES 3-VITESSE 

500 PCM (FIGURE 13A), 

régler à « 1 » pour vitesse basse (LOW), 

à « 2 » pour vitesse moyenne (MEDIUM) et à « 3 » pour vitesse 

élevée (HIGH).  

POUR MODÈLES 2-VITESSE 280 PCM (FIGURE 

13B), 

régler à « 1 » pour vitesse basse (LOW), et à « 3 » pour 

vitesse élevée (HIGH).

Summary of Contents for 280 CFM

Page 1: ...ty Title 24 HUD Part 280 Four wire power supply must be used and the appliance wiring must be revised See Electrical Requirements LISEZ BIEN CETTE FICHE AVANT D INSTALLER LA HOTTE AVERTISSEMENT POURMI...

Page 2: ...at the junction box When making the electrical connection cut a 1 1 4 hole in the wall A hole cut through wood must be sanded until smooth A hole through metal must have a grommet WARNING TOREDUCETHER...

Page 3: ...pareils combustion Suivez les conseils et mesuresdes curit dufournisseurtelsqueceuxpubli s par l Association Nationale de la Sauvegarde contre l Incendie et l Association Am ricaine d Ing nieurs de Ch...

Page 4: ...place 16 3 8 upper chimney S that came with hood Stainless White Black 620000070 620000164 620000165 OPTIONAL ACCESSORIES AVAILABLE ACCESSOIRES POUR L INSTALLATION B 24 high mounts to the wall beneath...

Page 5: ...f straight duct between elbows if more than one is used Do not install two elbows together If you must elbow right away do it asfarawayfromthehood sexhaustopening as possible WARNING Because of the we...

Page 6: ...cksplash will determine the bottom edge of the canopy 4 Thechimneymountsbytwobrackets 2inFIGURE5 Note the position of the brackets The top bracket should be installed about 1 8 away from the ceiling T...

Page 7: ...Attach the White lead of the power supply to the White lead of the rangehood with a twist on type wire connector Attach the Black lead of the power supply to the Black lead of the rangehood with a tw...

Page 8: ...For Best Results Start the rangehood several minutes before cooking to develop proper airflow Allow the unit to operate for several minutes after cooking is complete to clear all smoke and odors from...

Page 9: ...ed 500cfmversion willhaveoptionsofspeeds1 2 and 3 The 2 speed 280 cfm version will only have options of speeds 1 and 2 FIGURE 13A 3 SPEED 500 CFM 3 VITESSE 500 PCM FIGURE 13B 2 SPEED 280 CFM 2 VITESSE...

Page 10: ...umbing 2 Service calls to repair or replace range hood light bulbs fuses or filters Those consumable parts are excluded from warranty coverage 3 Repairs when your range hood is used for other than nor...

Page 11: ...installation avec conduit la ventilation peut s effectuer par le mur ou le plafond Pour une ventilation par le mur un coude de 90 est utilis Lorsque install e sans conduit la ventilation s effectue p...

Page 12: ...d installer les fixations installer les vis de r glage au bas de la fixation Ces deux vis sont fournies dans le n cessaire de ferrures et ont des t tes hexagonales avec une encoche pour un tournevis...

Page 13: ...6 Brancher le c ble d alimentation sur la hotte Attacher le fil blanc du c ble d alimentation sur le fil blanc de la hotte avec une cosse Attacher le fil noir du c ble d alimentation au fil noir de l...

Page 14: ...a cuisine Pour de meilleurs r sultats Mettre la hotte en circuit avant de commencer la cuisson Laisser l appareil fonctionner quelques minutes apr s la cuisson pour liminer la fum e et les odeurs de l...

Page 15: ...r les fusibles de votre maison ou pour corriger votre c blage ou votre syst me de plomberie 2 Les appels de service pour remplacer ou r parer les ampoules les fusibles ou les filtres de votre hotte de...

Page 16: ......