![Fabco Power HYDRO 300C Instruction Manual Download Page 9](http://html1.mh-extra.com/html/fabco-power/hydro-300c/hydro-300c_instruction-manual_3099454009.webp)
Fabco Power
Instruction Manual
•
Page 9
•
FIXED DISPLACEMENT
TYPE GEAR PUMP
5
6
4
7
3
2
1
TYPICAL HYDRAULIC SCHEMATIC
8
1.
HYDRAULIC PUMP
2.
PRESSURE RELIEF VALVE
3.
CONTROL VALVE
4.
PRIORITY FLOW CONTROL*
5.
GENERATOR HYRAULIC MOTOR
6.
CASE DRAIN LINE**
9
7. RETURN LINE FILTER
8. OIL COOLER
9.
HYDRAULIC FLUID RESERVOIR
*
Some units may be equipped with integral priority flow control, refer
to specific model number.
**
External case drain line may be required on some units refer to
specific model number.
When external case drain is required it should be unobstructed direct
return to reservoir with a minimum I.D. no less than that of case
drain port on generator motor.
FOR SPECIFIC INSTALLATION RECOMMENDATIONS CONSULT FACTORY