RECOMMENDATIONS              

MODEL: HYDRO 300C 

 
 
 

 

 

 

HIGH PRESSURE LINE ........................ 

½

 inch 

 
 

LOW PRESSURE LINE .......................... 

¾

 inch 

 
 

FLOW RATE .......................................... 8 to 25 GPM 

 

 

(8 GPM IDEAL) 

 
 

FOR BEST RESULTS KEEP HYDRAULIC OIL   

 

TEMPERATURE BETWEEN 80°F AND 120°F.   

 

DO NOT EXCEED 175°F. 

 
 

AN OIL COOLER IS RECOMMENDED. 

 
 

MAXIMUM BACK PRESSURE ............. 150 PSI 

 
 

WILL OPERATE ON ANY 2500 PSI OPEN CIRCUIT   

 

OR CLOSED LOOP SYSTEMS. 

 
 

RECOMMEND FILTER  ........................ 10m 

 
 

RECOMMEND HYDRAULIC OIL  ....... DEXTRON III A.T.F. 

 
 
 
 

INSTALLATION TIPS   

 

Excessive pressure in your return line will damage the hydraulic motor seal.  High back pressure can be caused by 
“spikes” sent back through the return from other equipment on a common return line.  Another potential problem 
can develop if several pieces of equipment are connected to one “common” return line causing a high back 
pressure (150 PSI is the maximum).  We recommend you run the return line from the generator back to the 
cooling tank with a separate line. 

 

You can either run the 3/4 inch return line back to the tank or leave the 3/4 inch line connected to a common 
return and run a separate 3/8 inch line from the case drain (located at the bottom of the hydraulic motor) directly 
back to the tank.  Either way you completely eliminate any problem of excessive return line pressure damaging 
your hydraulic motor. 
 
 
 
 

 
 

Summary of Contents for HYDRO 300C

Page 1: ...le Power Instruction Manual for Model HYDRO 300C Hydraulic Generator Manufacturing of Vehicle Mounted Generators Hydraulic Generators P O Box 582 Chester NY 10918 845 469 9151 Fax 845 469 7871 Web Sit...

Page 2: ...GENERATOR VOLTAGE 120 or 120 240 MOTOR STARTING 300 SURGE VOLTAGE REGULATOR INHERENT OUTPUT 3000 WATTS CONTINUOUS 4000 WATTS PEAK AT 100 F OIL TEMPERATURE HYDRAULIC MOTOR GEAR TYPE MAXIMUM SPEED 4200...

Page 3: ...back pressure can be caused by spikes sent back through the return from other equipment on a common return line Another potential problem can develop if several pieces of equipment are connected to o...

Page 4: ...cal load on the generator By using this setting you will have approximately 60HZ cycles or 3600 RPM when you are running at full rated load One way this can be accomplished is by using a Photo Tachome...

Page 5: ...what the load Drive motor speed control systems generally have a small drop in speed between no load and loaded conditions We therefore recommend setting no load speed 3 4 above nominal speed CHECKING...

Page 6: ...lace LOW NO LOAD VOLTAGE 1 Speed too low 2 Faulty rotary diodes 3 Breakdown in windings 4 Capacitor with high capacity 1 Check and adjust RPM s 2 Check and replace 3 Check winding resistance as per ta...

Page 7: ...w Control 25 572319 Mounting Strap 26 572331 Diodes 27 572332 Varistor 28 572333 Studs PART OPTIONAL CONTROL PANEL 29 572334 Thru Bolt 572227 Complete Control Panel 65 572062 Capacitor 20 MFD 572228 C...

Page 8: ...Fabco Power Instruction Manual Page 8 HYDRAULIC MOTOR HOSE HOOK UP Fabco Power...

Page 9: ...INE FILTER 8 OIL COOLER 9 HYDRAULIC FLUID RESERVOIR Some units may be equipped with integral priority flow control refer to specific model number External case drain line may be required on some units...

Page 10: ...Fabco Power Instruction Manual Page 10...

Page 11: ...Fabco Power Instruction Manual Page 11...

Page 12: ...Fabco Power Instruction Manual Page 12...

Page 13: ...Fabco Power Instruction Manual Page 13...

Page 14: ...Fabco Power Instruction Manual Page 14...

Page 15: ...Fabco Power Instruction Manual Page 15...

Reviews: