![background image](http://html1.mh-extra.com/html/faac/xib/xib_quick-start-manual_3111276003.webp)
-
+
-
+
-
+
-
+
BUS
BUS
BUS
BUS
ON
1 2 3 4
BUS
BUS
DS1
ON
1 2 3 4
BUS
BUS
DS1
ON
1 2 3 4
DS1
ON
1 2 3 4
DS1
CL
OP
XIB
ON
1 2 3 4
DS1
ON
1 2 3 4
DS1
DL1
DL2
XIB
BUS
CL
“ XIB ” BUS INTERFACE
(
*
) If no device should be connected to
the “J3 CL” or “J3 OP” terminals of the “XIB”,
the unused terminal must be connected
to the negative ( - ) of the FAAC control
board.
On the BUS photocells connected to
J2 of the “XIB”, NEVER configure DS1
as in the figure
J1
( RED )
Connector to be connected to
the “2easy” BUS coupling
on FAAC control board
J2
( RED )
Terminal board for the connection
of BUS accessories
(2easy photocells, encoder etc..)
J3 CL
( GREEN )
Terminal for the connection of
devices
operating at closure (CL) ,
with N.C. contact
(E.G. PHOTOCELLS, EDGES, ETC...)
J3 OP
( GREEN )
Terminal for the connection of
devices operating at opening (OP)
with N.C. contact
(E.G. PHOTOCELLS, EDGES, ETC...)
DL1
LED for diagnostics of devices
connected to the J3 OP terminal
(see diagnostic table)
DL2
LED for diagnostics of devices
connected to the J3 CL terminal
(see diagnostic table)
DIAGNOSTICS
OFF
SLOW FLASHING
(FLASH EVERY 5 secs.)
ON STEADY BEAM
FAST FLASHING
(FLASH EVERY 0.5 secs)
ALTERNATE FLASHING OF
“DL1” AND “DL2” LEDs
DL1
“XIB” board
broken
or not
powered
J3 OP terminal
open.
E.G. PHOTOCELL
ENGAGED,
NOT ALIGNED OR
NOT CONNECTED (*)
J3 OP terminal
closed
E.G. PHOTOCELL
NOT ENGAGED
AND ALIGNED
BUS photocell, connected to the
J2 terminal of the “XIB”, with the
configuration of:
DS1: OFF;ON;ON;ON
USE ANOTHER
DS1 COMBINATION
The “XIB” BUS interface
is not connected to a
“2easy” bus
output on the
FAAC control board
CONNECT
THE “XIB” INTERFACE
T O T H E “ 2 e a s y ” B U S
TERMINAL ON THE FAAC
control board
DL2
“XIB” board
broken
or
not
powered
J3 CL terminal
open.
E.G. PHOTOCELL
ENGAGED,
NOT ALIGNED OR
NOT CONNECTED (*)
J3 CL terminal
closed
E.G. PHOTOCELL
NOT ENGAGED
AND ALIGNED
BUS photocell, connected to the
J2 terminal of the “XIB”, with the
configuration of:
DS1: ON,ON,ON,OFF
USE ANOTHER
DS1 COMBINATION
DEVICES WITH N.C. CONTACT
OTHER DEVICES WITH N.C. CONTACT
BUS COUPLING ON FAAC control board
BUS PHOTOCELLS “2easy”
DO
NOTT
PHOTOCELLS AT CLOSURE
PHOTOCELLS AT OPENING
Summary of Contents for XIB