background image

 

 


+


+

 

 

 

 


+


+

 

 

BUS

BUS

BUS

BUS

ON

1   2   3 4

BUS

BUS

DS1

ON

1   2   3 4

BUS

BUS

DS1

ON

1   2   3 4

DS1

ON

1   2   3 4

DS1

 

 

 

 

CL

OP

XIB

ON

1   2   3 4

DS1

ON

1   2   3 4

DS1

DL1

DL2

XIB

BUS

CL

“ XIB ” BUS INTERFACE

(

*

) If no device should be connected to

the “J3 CL” or “J3 OP” terminals of the “XIB”,

the unused terminal must be connected

to the negative ( - ) of the FAAC control

board.

On the BUS photocells connected to

J2 of the “XIB”, NEVER configure DS1

as in the figure

J1

( RED )

Connector to be connected to 

the  “2easy”  BUS    coupling            

on FAAC control board

J2

( RED )

Terminal board for the connection 

of BUS accessories

(2easy photocells, encoder etc..)

J3  CL

( GREEN )

Terminal for the connection of

devices

 operating at closure (CL) , 

with N.C. contact

(E.G. PHOTOCELLS, EDGES, ETC...) 

J3 OP

( GREEN )

Terminal for the connection of 

devices operating at opening (OP)  

with N.C. contact

(E.G. PHOTOCELLS, EDGES,  ETC...)  

DL1

LED for diagnostics of devices 

connected to the J3 OP terminal 

(see diagnostic table)

DL2

LED for diagnostics of devices 

connected to the J3 CL terminal 

(see diagnostic table)

DIAGNOSTICS

OFF

SLOW FLASHING  

(FLASH EVERY 5 secs.)

ON STEADY BEAM

FAST FLASHING

(FLASH EVERY 0.5 secs)

ALTERNATE FLASHING OF 

“DL1” AND “DL2” LEDs 

DL1

“XIB” board 

broken

 or not 

powered

J3 OP terminal

open.

E.G. PHOTOCELL

ENGAGED,

NOT ALIGNED OR  
NOT CONNECTED  (*)

J3 OP terminal

closed

E.G. PHOTOCELL

NOT ENGAGED

AND ALIGNED

BUS photocell, connected to the 
J2 terminal of the “XIB”, with the 

configuration of:

 DS1: OFF;ON;ON;ON 

USE ANOTHER

DS1 COMBINATION

The “XIB” BUS interface 

is not connected to a 

 “2easy” bus

 output on the 

FAAC control board

CONNECT

THE “XIB” INTERFACE

T O T H E “ 2 e a s y ” B U S  
TERMINAL ON THE FAAC

control board

DL2

“XIB” board 

broken

 or 

not

powered

J3 CL terminal 

open.

E.G. PHOTOCELL

ENGAGED,

NOT ALIGNED OR  
NOT CONNECTED  (*)

J3 CL terminal    

closed

E.G. PHOTOCELL

NOT ENGAGED

AND ALIGNED

BUS photocell, connected to the 
J2 terminal of the “XIB”, with the 

configuration of:

DS1: ON,ON,ON,OFF

USE ANOTHER

DS1 COMBINATION

DEVICES WITH N.C. CONTACT

OTHER DEVICES WITH N.C. CONTACT

BUS COUPLING ON FAAC control board

BUS PHOTOCELLS “2easy”

DO

NOTT

PHOTOCELLS AT CLOSURE

PHOTOCELLS AT OPENING

Summary of Contents for XIB

Page 1: ...XIB...

Page 2: ...positivi collegati al morsetto J3 CL vedi tabella diagnostica DIAGNOSTICA SPENTO LAMPEGGIO LENTO FLASH OGNI 5 sec ACCESO FISSO LAMPEGGIO VELOCE FLASH OGNI 0 5 sec LAMPEGGIO ALTERNATO DEI LED DL1 E DL2...

Page 3: ...stics of devices connected to the J3 CL terminal see diagnostic table DIAGNOSTICS OFF SLOW FLASHING FLASH EVERY 5 secs ON STEADY BEAM FAST FLASHING FLASH EVERY 0 5 secs ALTERNATE FLASHING OF DL1 AND D...

Page 4: ...ispositifs connect s la borne J3 CL voir tableau diagnostic DIAGNOSTIC TEINTE CLIGNOTEMENT LENT FLASH TOUTES LES 5 s ALLUM E FIXE CLIGNOTEMENT VITE FLASH TOUTES LES 0 5 s CLIGNOTEMENT ALTERNATIF DES L...

Page 5: ...nosetabelle DIAGNOSE AUS LANGSAMES BLINKSIGNAL kurzes Aufblinken im Abstand von 5 Sekunden EIN MIT DAUERLICHT SCHNELL BLINKSIGNAL kurzes Aufblinken im Abstand von 0 5 Sekunden A B W E C H S E L N D E...

Page 6: ...agn stico DL2 Diodoparadiagn sticodedispositivos conectados al borne J3 CL v ase tabla de diagn stico DIAGN STICO APAGADO DESTELLO LENTO FLASH CADA 5 seg ENCENDIDO FIJO DESTELLO RAPIDO FLASH CADA 0 5...

Page 7: ...tingen zie tabel diagnostiek DL2 Led voor diagnostiek van op klem J3 CL aangesloten inrichtingen zie tabel diagnostiek DIAGNOSTIEK UIT KNIPPERT LANGZAAM FLASH IEDERE 5 sec BRANDT KNIPPERT IEDERE 0 5 s...

Page 8: ...ion typique homog ne Tous les produits sont fabriqu s par FAAC S p A Bologna le 1 Mai 2008 L Administrateur D l gu A Bassi CE KONFORMIT TSERKL RUNG Der Hersteller FAAC S p A Anschrift Via Benini 1 400...