MOUNTING SIDE

Stay outside of the detection 

field to avoid disturbances.

Select the corresponding mounting side.

The sensor then learns its environment and automatically 

determines the detection field(s). Both red LEDs flash slowly and 

the 3 visible laser beams automatically light up during 30 seconds.

WITH BACKGROUND

WITHOUT BACKGROUND

The sensor memorizes the floor as reference point 
and will signal a fault in case the orientation of the 
sensor is changed (on purpose or by accident).

No reference point is memorized, 
no alarm in case of interference 
with sensor position.

Adjust the 

lateral position

 of 

the detection field.

Adjust the 

tilt angle

 of the 

detection field with the hex 

key.

Lock the position

 of the 

mounting bracket to avoid 

malfunctioning in case of 

extreme vibrations.

Unlock the sensor and activate the visible laser beams.

The visible laser beams indicate approximately 
the postion of curtain C1 and limit the angle of 
the detection field.

The visible laser beams stay activated for 

15 minutes or can be turned off the same way 

they were activated.

POSITIONING

left

right

centre

C1

C2

C3

C4

Summary of Contents for XGUARD-25

Page 1: ...1 XGUARD 25 Laser scanner for building automation and security EN User s Guide for product version 0600 and more...

Page 2: ...Caution Laser radiation LED flashes quickly LED flashes LED is off Remote control sequence Other use of the device is outside the permitted purpose and can not be guaranteed by the manufacturer The ma...

Page 3: ...red laser beams The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel Only trained and qualified personnel may install and adjust the sensor Avoid extreme vibra...

Page 4: ...ggers relay 1 Field 2 only curtain C1 active triggers relay 2 alarm During night time field 2 is active too and triggers relay 2 intrusion alarm protection of works of art WARNING ALARM day and night...

Page 5: ...e mounting template Make a hole for the cable if possible Pass the cable 10 cm though the cable opening If drilling an opening is not possible use the cable conduits on the back side of the bracket Po...

Page 6: ...sensor is changed on purpose or by accident No reference point is memorized no alarm in case of interference with sensor position Adjust the lateral position of the detection field Adjust the tilt an...

Page 7: ...cut out IMPORTANT Test the good functioning of the installation before leaving the premises Stay outside of the detection field to avoid disturbances WIDTH field 2 field 1 HEIGHT no field WIDTH HEIGH...

Page 8: ...th fields activate curtain only on field 1 activate curtain only on field 2 activate curtain on both fields EX All curtains active on both fields The distances between the curtains depend on the mount...

Page 9: ...AVING AN ACCESS CODE DELETING AN ACCESS CODE The access code is recommended for sensors installed close to each other After unlocking the red LED flashes and the sensor can be adjusted by remote contr...

Page 10: ...and connexion Check wiring The red and blue cable have to be connected to the test input or the power supply Check the size of the fields Launch a teach in Step out of the field and or remove the any...

Page 11: ...er 75 W CLASS 1 wavelength 650 nm max output CW power 3 mW CLASS 3R 10 35 V DC sensor side 5 W 1 8 A max 80 ms 35 V 10 m typ 20 ms max 80 ms output activation delay 2 electronic relays galvanic isolat...

Page 12: ...that the FAAC XGUARD 25 is in conformity with the basic requirements and the other relevant provi sions of the directives 2006 95 EC 2002 95 EC and 2004 108 EC Angleur August 2013 Pierre Gardier Autho...