SAFETY

INSTALLATION AND MAINTENANCE

The device contains IR and visible laser diodes.

IR laser: wavelength 905nm; max. output pulse power 75W 

(Class 1 according to IEC 60825-1)

Visible laser: wavelength 650nm; max. output CW power 3mW 

(Class 3R according to IEC 60825-1)

The visible laser beams are inactive during normal functioning.

The installer can activate the visible lasers if needed.

CAUTION!

 

Use of controls, adjustments or performance of procedures other than those specified herein 

may result in hazardous radiation exposure.

Do not look into the laser 

emitter or the visible red 

laser beams.

The warranty is void if 

unauthorized repairs are 

made or attempted by 

unauthorized personnel. 

Only trained and qualified 

personnel may install and 

adjust the sensor. 

Avoid extreme

vibrations.

Do not cover 

the front screens.

Avoid moving objects 

and light sources in 

the detection field.

Avoid condensation.

Avoid the presence 

of smoke and fog in 

the detection field.

Avoid exposure to 

sudden and extreme 

temperature changes.

Keep the sensor 

permanently powered 

in environments where 

the temperature can 

descend below 0°C.

Wipe the front 

screens regularly 

with a clean and 

damp cloth.

Do not use aggressive 

products to clean 

the front screens.

Test the good functioning 

of the installation before 

leaving the premises.

Avoid direct exposure 

to high pressure 

cleaning.

Summary of Contents for XGUARD-25

Page 1: ...1 XGUARD 25 Laser scanner for building automation and security EN User s Guide for product version 0600 and more...

Page 2: ...Caution Laser radiation LED flashes quickly LED flashes LED is off Remote control sequence Other use of the device is outside the permitted purpose and can not be guaranteed by the manufacturer The ma...

Page 3: ...red laser beams The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel Only trained and qualified personnel may install and adjust the sensor Avoid extreme vibra...

Page 4: ...ggers relay 1 Field 2 only curtain C1 active triggers relay 2 alarm During night time field 2 is active too and triggers relay 2 intrusion alarm protection of works of art WARNING ALARM day and night...

Page 5: ...e mounting template Make a hole for the cable if possible Pass the cable 10 cm though the cable opening If drilling an opening is not possible use the cable conduits on the back side of the bracket Po...

Page 6: ...sensor is changed on purpose or by accident No reference point is memorized no alarm in case of interference with sensor position Adjust the lateral position of the detection field Adjust the tilt an...

Page 7: ...cut out IMPORTANT Test the good functioning of the installation before leaving the premises Stay outside of the detection field to avoid disturbances WIDTH field 2 field 1 HEIGHT no field WIDTH HEIGH...

Page 8: ...th fields activate curtain only on field 1 activate curtain only on field 2 activate curtain on both fields EX All curtains active on both fields The distances between the curtains depend on the mount...

Page 9: ...AVING AN ACCESS CODE DELETING AN ACCESS CODE The access code is recommended for sensors installed close to each other After unlocking the red LED flashes and the sensor can be adjusted by remote contr...

Page 10: ...and connexion Check wiring The red and blue cable have to be connected to the test input or the power supply Check the size of the fields Launch a teach in Step out of the field and or remove the any...

Page 11: ...er 75 W CLASS 1 wavelength 650 nm max output CW power 3 mW CLASS 3R 10 35 V DC sensor side 5 W 1 8 A max 80 ms 35 V 10 m typ 20 ms max 80 ms output activation delay 2 electronic relays galvanic isolat...

Page 12: ...that the FAAC XGUARD 25 is in conformity with the basic requirements and the other relevant provi sions of the directives 2006 95 EC 2002 95 EC and 2004 108 EC Angleur August 2013 Pierre Gardier Autho...

Reviews: