The first two digits are the enabling of the outputs for reading on 
A, whereas the last two digits are the enabling of the outputs for 
reading on B. 

25 x 1001

 E

 = User 25 enables output 1 for reading on A 

and output 2 for reading on B. 

15 x 0001

 E

 = User  15 enables output 2 for reading on B. 

 

MENU 4 IMPORT DATA 

This option makes it possible to import to the control unit, all the data which were previously stored on an external memory board (MEM-EXP) 

• 

Enter the function with:

 4 x Master Code

 E

 

or with:

 4 then the Master Card reading

 

• 

Type in the 

number 

which stands for the type of Import to be executed followed by 

E

 . These are the  possibilities: 

= Total import 

= import Codes + Settings 

3

 = import codes only 

= import Settings only 

 

MENU 5 EXPORT DATA 

This option makes it possible to export to an external memory board (MEM-EXP), all the data which were previously stored on the control unit. 

• 

Enter the function with: 

 5 x Master Code

E

 

or with:

 5 then the Master Card reading

 

• 

Type in the 

number 

which stands for the type of Export to be executed followed by 

E

 . These are the  possibilities: 

1

 = Total export 

2

 = export Codes + Settings 

3

 = export Codes only 

= export Settings only 

 

MENU 6 CONFIGURATION INPUT/OUTPUT 

With this menu you can set: the function logic of the inputs and the activation times of the control unit outputs. 

 

• 

Enter the function with:

 6 x Master Code

 E

 

or with:

 6 then the Master Card reading

 

• 

Type in the 

command 

to vary the required parameter. The command consists of two values separated by key x. The first value is the function to 

be set, whereas the second value can express: a time or a logic.

 

Description  

Command 

Default  

Example of typing in 

Relay 1 time (in tenths) 

1xT (T = time 0 - 65535) 

30 

1x387

 E

 for time of 38 sec. and 7 tenths. 

1x5

 E

 for a time of 5 tenths 

Relay 2 time (in tenths) 

2xT (T = time 0 - 65535) 

30 

2x60

 E

 for a time of 60 tenths 

Alarm exit Time (in tenths) 

3xT (T = time 0 - 65535) 

300 

3x150

 E

 for a time of 150 tenths 

"Door status" disabling time (sec) 

4xT (T = time 0 - 65535) 

16 

4x25

 E

 for a time of 25 seconds 

Electric strike management  

5x1 = Yes (5x0 =No) 

 

5x1

 E

 activates electric encounter management   

Logic INP1 

6x1 = NC (6x0 =NO) 

NO 

6x1

 E

 logic NC. “6x0” logic NO 

Logic IngP2 

7x1 = NC (7x0 =NO) 

NO 

7x1

 E

 logic NC. “7x0” logic NO 

Tamper Input Logic 

8x1 = NC (8x0 =NO) 

NC 

8x1

 E

 logic NC. “8x0” logic NO 

Logic INP-AUX 

9x1 = NC (9x0 =NO) 

NO 

9x1

 E

 logic NC. “9x0” logic NO 

 

MENU 7 CONFIGURATION READER B 

This configuration makes it possible to program the functions of reader B: 

• 

Enter the function with:

 7 x Master Code

 E

 

or with:

 7 then the Master Card reading

 

• 

Type in the 

command 

to vary the required parameter. The command consists of two values separated by key x.  The first value is the function to 

be set, whereas the second value can express: a time or an enabling operation.

 

 
MENU 8 ACTIVATION INTERNAL/EXTERNAL CARD READER 

The above mentioned menu enables you to activate/disable card reader  A or B. 

• 

Enter the function with:

 8 x Master Code

 E

 

or with:

 8 then the Master Card reading

 

• 

Type in the 

command 

to vary the required parameter. The command consists of two values separated by key x. The first value is the function to 

be set, whereas the second value is the activation/disabling to be executed.  

Command 

Default  

Description  

Example of typing in 

1x1 = Yes (1x0 = No) 

Yes 

Activates RF Module for Passive cards 

1x1

 E

 

 to activate. 1x0

 E

 to disable. 

2x1 = Yes (2x0 = No) 

No 

Activates card reader B 

2x1

 E

 to activate  2x0

 E

 to disable 

 
 
 

SPECIAL COMMANDS 

65000 × “MASTERCODE

 E

” = All absent 

65000 then reading “MASTERCODE

 E

” = All absent 

65001 × “MASTERCODE

 E

” = All present 

65001 then reading “MASTERCODE

 E

” = All present 

65300 × “MASTERCODE

 E

”  = Cancel "User Codes" only” 

65300 then reading “MASTERCODE

 E

” = Cancel "User Codes" only” 

65301 × “MASTERCODE

 E

”  = Reset settings only (+ Def.) 

65301 then reading “MASTERCODE

 E

” = Reset settings only (+ Def.) 

65534 × “MASTERCODE

 E

”  = Cancel “Master-Code” only 

65534 then reading “MASTERCODE

 E

” = Cancel “Master-Code” only 

65535 then reading “MASTERCODE

 E

” = Reset all (and put on Default)

 

65535 × “MASTERCODE

 E

”  = Reset all (and put on Default) 

 

Rapid Guide Resist-SA TAG10 SA ver.1-1 rev. A  

 

3

Description  

Command 

Default 

Example of typing in 

Reader B ignore time in seconds 

1xT (T = time 0 ÷ 255) 

1x10

 E

 for a time of 10 sec. 

Double gateway 

2x1 = Yes (2x0 = No) 

No 

2x1

 E

 to enable “Double gateway” 

Management of door associated with B 

3x1 = Yes (3x0 = No) 

No 

3x1

 E

 for “Door management” associated with B 

Antipassback 

4x1 = Yes (4x0 = No) 

No 

4x1

 E

 to activate Antipassback (APB) 

No Antipassback at Exit 

5x1 = Yes (5x0 = No) 

Yes 

5x0

 E

 on Exit reader, use APB 

Reader B Entry 

6x1 = Yes (6x0 = No) 

Yes 

6x1

 E

 reader B for Entry and A for Exit 

Reset Card 1 

7xN (N = Card No.) 

7x499

 E

 Reset Card 1 is 499 

Reset Card 2 

8xN (N = Card No.) 

8x500

 E

 Reset Card 2 is 500 

LRC reader B 

9x1 = Yes (9x0 = No) 

Yes 

9x0

 E

 disables LRC on reader B 

Wiegand/Mag-stripe 

10x1 = Wie (10x0 = M-S) 

M-S 

10x1

 E

reader B is Wiegand 