Rapid Guide Resist-SA TAG10 SA ver.1-1 rev. A  

 

2

CONFIGURATION MASTER CODE / MASTER CARD 

 

To start the configuration of the different parameters of the unit Resist SA or TAG10 SA, it is necessary to store first on the unit  the master code or  
the master card. 
As the equipment is provided without master code/master card, the first operation necessary to make will be to store the code/card on the device. 
Therefore you need to do as follows: 

• 

Verify that the 3 frontal led flash simultaneously. 

• 

Type the code (min. 6 max. 14 characters) than type E, or read the Master card. 

• 

If the operation has been executed in a correct way, only the amber led on the front panel will be activated 

IMPORTANT: it is necessary to keep the memorised master code or master card  in a safe place as it has to be used to execute all the variations of the 
control unit configuration.  
 

PROGRAMMING 

 
The programming of all the parameters of  Resist SA or TAG 10 SA can be obtained by choosing  one of the eight menus available and by typing the 
master code or reading the master card. The following table shows the characteristics of the 8 options that can be programmed  

Menù 

Kind of programming 

Commands with Master Code 

Commands with Master Card 

Inputting new users 

1 x Master Code E 

1 + reading  Master Card 

Cancelling users 

2 x Master Code E 

2 + reading  Master Card 

Qualification of users 

3 x Master Code E 

3 + reading  Master Card 

Import data 

4 x Master Code E 

4 + reading  Master Card 

Export data 

5 x Master Code E 

5 + reading  Master Card 

Configuration input/output 

6 x Master Code E 

6 + reading  Master Card 

Configuration reader B 

7 x Master Code E 

7 + reading  Master Card 

Activation internal /external card reader 

8 x Master Code E 

8 + reading  Master Card 

IMPORTANT: the command enables to enter into the relevant menu, in which you can execute all the operations explained consecutively.  It is 
important to underline that x means button X while E means typing button E. 

 

To get out of the programming mode, you have to type X  for at least 4 seconds. 
 

MENU 1 INPUTTING NEW USERS 

To input the users in the control unit archive, you have to indicate for each user, the location number of the memory where the relevant code or card 
will be stored.  Available numbers are from 1 to 500 and, obviously, they can house a single data-item.

 

• 

Enter the function with:

 1 x Master Code

 E

 

or with:

 -1 then the Master Card reading

 

• 

Type in the 

location No.

 followed by 

x

, then the 

user code 

and then 

E

, or followed by the 

card reading.

 For example, if you want to store code 

2894 in location 23, the command will be: 

23 x 2894 E

 instead, if you want to store a  proximity card in location 37, the command will be:     

37 then the Card reading

 

• 

Continue like this and input all the necessary codes/cards, then press key E for at least 4 seconds to exit programming, or read the master card.

 

NB: we advise you to take a  note of the number of the locations and the relevant stored users, so that the code or card can be eliminated after card or 
right of access has been lost. The user code must have min 4 and max 6 characters. .

 

 

MENU 2 CANCELLING USERS 

To cancel users from the control unit archive, you must obviously know the memory location number where the relevant code or card was stored. If 
you have the card to be cancelled, just read it after entering the mode.

 

• 

Enter the function with:

 2 x Master Code

 E

 

or with:

 2 then the Master Card reading

 

• 

Type in the 

location No. 

of the code/card to be cancelled followed by 

E

. If, for example, you wish to cancel the code/card of location 23, the 

command will be:

23 

 

• 

Continue like this and cancel all the necessary codes/cards, then press key 

E

 for at least 4 seconds to exit programming, or read the master card.

 

 

MENU 3 QUALIFICATION OF USERS 

This function enables you to change the access characteristics of a single user or of a group of users. The following can be indicated for every stored 
code/card: the activation (output No.) which the control unit must execute, the direction (absent/present), if it is subjected to antipassback

 

• 

Enter the function with:

 3 x Master Code

 E

 

or with:

 3 then the Master Card reading

 

• 

To execute the required modifications, you must first indicate the 

location number 

or the 

range of locations

 where the codes/cards are stored, 

then the 

command 

which varies the characteristics. The following table expresses this concept, where 

NNN

 or 

FFF

 are the location number of 

the code/card and 

C

 is the command that changes the parameters.: 

Kind of typing 

Description 

                      NNN x C 

Displays data of code/card stored at NNN location 

                      NNN x FFF x C 

Set data for code/card stored from NNN to FFF locations 

                      1111 x C 

Set data for all code/card stored 

• 

The list of available commands and their meaning is explained in the following table: 

CommandC Description 

Examples 

5 Force 

“Absent” 

37 x 5 = User 37 Absent 

6 Force 

“Present” 

115 x 6 = User 115 Present 

Force subjected to “Antipassback” 

21 x 7 = User 21 Subjected to  Antipassback 

Force not subjected to “Antipassback” 

3 x 8 = User 3 Not subjected to  Antipassback 

11 
10 
01 
00 

For reading on A, both output 1 and output 2 are switched on 
For reading on A,  only output 1 is switched on 
For reading on A,  only output 2 is switched on 
For reading on A,  both output1 and output 2  are switched off 

23 x 11 = User 23 switch on both outputs 
48 x 10 = User 48 switch on output1 
57 x 01 = User 57 switch on output2 
21 x 00 = User 21 no switch on anything 

1111 

…. 

The command sets the enabling of the outputs, with the same 
logic defined for reading on A; (see above box).  

63 x 1111 = User 63 enables output 1 and output 2 

whether reading is on A or B. 