Function
default
nd
Cycle counter (x10)
00...99
in steps of 10
00
So
SAFE OP input configuration
nc
Sensitive edge with NC contact
1r
1 Resistive sensitive edge 8.2 kΩ
2r
2 Resistive sensitive edges 8.2 kΩ in
parallel
PH
Photocell with a NC contact
1r
Sc
SAFE CL input configuration
nc
Sensitive edge with NC contact
1r
1 Resistive sensitive edge 8.2 kΩ
2r
2 Resistive sensitive edges 8.2 kΩ in
parallel
PH
Photocell with a NC contact
1r
iP
Sensitive edge reverse mode
Y
Partial reverse 3 s
no
Total reverse
Y
bu
Learn BUS 2easy devices
See the relative section
PF
Pre-flashing for 3 s on the LAMP output
no
No pre-flashing
OC
Pre-flashing before every movement
CL
Pre-flashing before closing
no
tL
Learn work time (SETUP)
In order for the learning procedure to be carried
out, the CLOSED limit switch must be engaged
by the gate.
Press the + and - buttons simultaneously to
start the learning function.
If no button is pressed within 2 minutes, you
automatically exit from programming mode.
St
Exit from programming mode and display
the status of the automation:
00
CLOSED
01
OPEN
03
STOPPED
04
IN PAUSE
05
OPENING
06
CLOSING
09
PRE-FLASHING and then OPENS
10
PRE-FLASHING and then CLOSES
6.2 OPERATING LOGICS
The STOP command has priority over all other com-
mands and stops the automation in all the logics.
In all the logics, except B and C, the OPEN B command
partially opens the gate if it is closed, in all other states
it has the same function as the OPEN A command.
In logics B and C (separate opening and closing com-
mand logics), OPEN B only closes the gate.
■
A
AUTOMATIC
This logic only requires the OPEN command to be used.
OPEN if the automation is closed, causes it to
open. The automation closes automatically after the
pause time has elapsed.
OPEN during pause, resets the pause time.
OPEN during opening, is ignored.
OPEN during closing, causes it to reopen.
If the closing photocells are triggered during the pause
time, they reset the pause time.
■
AP
AUTOMATIC STEP-BY-STEP
This logic only requires the OPEN command to be used.
OPEN if the automation is closed, causes it to
open. The automation closes automatically after the
pause time has elapsed.
OPEN during pause, stops it and the next OPEN
command closes it.
OPEN during opening, stops it and the next OPEN
command closes it.
OPEN during closing, causes it to reopen.
If the closing photocells are triggered during the pause
time, they reset the pause time.
■
S
AUTOMATIC SAFETY
This logic only requires the OPEN command to be used.
OPEN if the automation is closed, causes it to
open. The automation closes automatically after the
pause time has elapsed.
OPEN during the pause, causes it to close.
OPEN during opening, causes it to close.
OPEN during closing, causes it to reopen.
If the closing photocells are triggered during the pause
time, they close the automation 3 seconds after they
have been released.
■
E
SEMI-AUTOMATIC
This logic only requires the OPEN command to be used.
OPEN if the automation is closed, causes it to open.
OPEN if the automation is open, causes it to close.
OPEN during opening, stops it and the next OPEN
command closes it.
OPEN during closing, causes it to reopen.