ADVANCED PROGRAMMING
F
+
+
Display
Function
Default
MAXIMUM TORQUE AT INITIAL THRUST:
The motors operate at maximum torque (ignoring the
torque setting) at start of movement. Useful for heavy
leaves.
=Active
=Disabled
FINAL STROKE ON CLOSING:
The motors are activated at full speed for 1 s to
facilitate locking of the electric lock.
= Active
= Disabled
Note: disabled in case of a sliding
automated system.
REVERSING STROKE:
Before opening, while the gate is closed, the motors
thrust to close for 2 s thus facilitating release of the
electric lock.
= Active
= Disabled
Note: disabled in case of a sliding
automated system.
LEAF 2 OPENING DELAY (2 s):
Enables delayed start (on opening) of leaf 2, avoiding
interference between leaves.
= Active
= Disabled
FAIL SAFE:
If this function is activated, it enables an operation test
of the photocells before any gate movement. If the
test fails (photocells not serviceable), the gate does
not start the movement.
= Active
= Disabled
PRE-FLASHING (5 s):
Activates the flashing lamp for 5 s before start of
movement.
= Active
= Disabled
ELECTRIC LOCK ON LEAF 2:
For using the electric lock on leaf 2 instead of on leaf 1.
=Active
=Disabled
INDICATOR-LIGHT:
If is selected, the output functions as a standard
indicator-light (lighted on opening and pause, flashing
on closing, and off when gate closed). Different figures
correspond to timed activation of the output, which
can be used (via a relay) to power a courtesy lamp.
Time can be adjusted from to
s in 1 s steps, and
from
to
min. in 10 s steps.
= Standard indicator-light
from to
= Timed output
CLOSING PHOTOCELLS REVERSE
ON
RELEASE:
Enable this function if you want the closing photocells
to stop movement and reverse it
on
release. Default
setting is immediate reverse.
=Active
=Disabled
ASSISTANCE REQUEST
(combined with next function):
If activated, at the end of countdown (settable with
the next function "Cycle programming") it effects 8 s of
pre-flashing at every Open pulse (job request). Can be
useful for setting scheduled maintenance jobs.
=Active
=Disabled
CYCLE PROGRAMMING:
For setting countdown of system operation cycles.
Settable (in thousands) from
to
thousand
cycles.
The displayed value is updated as cycles proceed.
This function can be used to check use of the board or
to exploit the "Assistance request".
A.D.M.A.P. function:
If this function is enabled, the safety devices operate in
compliance with French standard NFP 25/362.
=Active
=Disabled
Display
Function
Default
GEARMOTOR FOR SLIDING GATE
This function should be activated if the 462DF is
commanding a gearmotor for a sliding gate.
= Active
= Disabled
Note: if this function is activated, the
and
functions are disabled.
DECELERATION FOR SLIDING GATE
Sets deceleration in hundredths of a second after the
limit-switch has operated.
Programmable
from
to
hundredths of a
sec.Note: modify this setting only if using a gearmotor
for sliding gates (function
active).
BRAKING FOR SLIDING GATE
Sets braking time in hundredths of a sec. at end of
deceleration.
Programmable
from
to
hundredths of a
sec.
PARTIAL OPENING FOR SLIDING GATE
Sets partial opening time in sec. commanded by the
OPEN-B input of the 462DF, only if using a gearmotor for
sliding gate (function
active).
Programmable
from
to
minutes (for the
adjustment mode, see Pause time).
DOWNLOAD
Downloads the programming to board 462DF.