4
3
ENGLISH
DESCRIPTION AND USE OF ENERGY SAVING
1) Function description:
An automated system that can operate in “Energy
Saving” mode. Thanks to this operating mode the system is able
to recognize the pedestrian direction (approaching, leaving or
side transit) and, as a consequence, to limit false opening
operations and reduce opening/closing times.
2) Compulsory use mode:
The “Energy Saving“ function can only be enabled together
with the XV1 o XDT1 double-technology presence and pulse detectors.
Important : A detector only is not sufficient to activate the “ Energy Saving “ function.
The described function can only be activated with XV1 o XDT1 internal
and
external
sensor.
The passage width VP max. for an XV1 o XDT1 sensor in order to use the Energy Saving function is 2mt.
For a passage width VP over 2mt., use 2 XV1 o XDT1 side-by-side sensors with a different frequency
and configured as indicated in XV1 o XDT1 manual
3) Use instructions
To guarantee maximum safety the use instructions of XV1 o XDT1
sensor must be carefully observed.
For any depth adjustment operations, use the
Spotfinder detector.
This accessory device enables you to detect the position of the
infrared field curtains for spot so exactly that you can adjust both
the command-pulse area and the safety area on the passage
width of our XV1 o XDT1 active infrared sensors in a precise manner.
For any further explanation, consult the use manual of the XV1 o XDT1 sensor.
4) “ Energy Saving “ function activation mode.
To activate the “ Energy Saving “ function you need to reach
parameter PA on the board display and set it to NO or use
the SD-KEEPER with DISPLAY and, when in programming mode, select:
Menu 2 SETUP ----> 2.2 Pause time ---->Off
1
2
3
4
5
6
7
8
9
10
11
12
13
J7
I-DET
E-DET
KEY
EMERG1
EMERG2
-FAILSAFE
OUT1
+24V
+24V
GND
GND
P
P
12-24 V
AC-DC
Green
Brown
Yellow
White
Pink
Grey
Supply
Red
Blue
test output
entry
security
entry
opening
XV1 o XDT1
XV1 o XDT1
White
White
Pink
Pink
Blue
Red
Green
Brown
Yellow
Grey