12  ASSEMBLING THE HOUSING

12.1  ASSEMBLING THE PLASTIC HOUSING

HOUSING FIXING SCREWS

Fig.18

11  FAILSAFE TEST TO MONITOR THE SAFETY SENSORS (dip switch 9 ON) EN 16005  

   sensor monitoring, as required by EN 16005, is only guaranteed if sensors XPB34-1/70-1 XPB90-

1/90-2 are used

The failsafe test allows the operator’s electronic board 950N to monitor any safety sensors installed, before each mo-

vement. 

Dip 9 must be set to ON in order to enable it.

If the failsafe test is not successful, the movement in that direction is inhibited until the test is successful.   If the KP 

Controller is connected, the following alarms are displayed:  

ALARM 13 = failsafe test failed on closing -

ALARM 14 = failsafe test failed on opening.

If both alarms are triggered, the first one to be detected is displayed.

   Set DIP 9 to ON for the interlock function between two doors and the gong cannot be activated.  

In a master and slave application, all the sensor connections (contacts, test, etc.) must be brought 

to the board set as master.

.12  LOW ENERGY (dip switch 9 OFF) EN 16005

Standard EN 16005 stipulates that in LOW ENERGY mode, the kinetic energy of a moving door must not exceed 

1.69 J. For this to happen, Dip 9 must be set to OFF and the opening and closing speed must be adjusted via the KP 

CONTROLLER. These settings must guarantee compliance with the values in the table below.

 

   The “LOW ENERGY” tables found on page 7 can provide an indicative value of the speed to be 

set.  However, the speed value set must be verified that it guarantees compliance with EN 16005.

The table provides the settings regarding the minimum opening and closing time with reference to the most com-

mon widths and masses of doors

LEAF WIDTH

(m)

LEAF WEIGHT (Kg)

50

60

70

80

90

OPENING/CLOSING TIME (s)

0.75

3.0

3.0

3.0

3.0

3.5

0.85

3.0

3.0

3.5

3.5

4.0

1.00

3.5

3.5

4.0

4.0

4.5

1.20

4.0

4.5

4.5

5.0

5.5

 

   - Set DIP 9 to OFF for the SCP function to always be disabled.

Summary of Contents for 950N

Page 1: ...950 N EN 16005...

Page 2: ...950N 1 732708 Rev F BRACCIO ARTICOLATO ARTICULATED ARM BRAS ARTICUL BRAZO ARTICULADO GELENKARM KNIKARM LEDAD ARM a a b c d e f f h a g a c c a OPEN OPEN...

Page 3: ...se the optional extensions dimension with 50 mm shaft 87 mm with 80 mm shaft 117 mm Cote avec arbre standard de 20 mm S il est n cessaire d augmenter la distance entre l op rateur et le bras utiliser...

Page 4: ...elle 20 mm Wenn der Abstand zwischen dem Antrieb und dem Arm erh ht werden muss die optionalen Verl ngerungen verwenden Ma mit 50 mm Welle 87 mm Ma mit 80 mm Welle 117 mm Afstand met standaardas 20 mm...

Page 5: ...950N 4 732708 Rev F BRACCIO A PATTINO SLIDING ARM BRAS PATIN BRAZO DE PAT N GLEITKUFENARM ARM MET GLIJSCHOEN GLIDARM a a b e d d f f g i h j k OPEN...

Page 6: ...tor and the arm use the optional extensions dimension with 50 mm shaft 107 mm with 80 mm shaft 137 mm Cote avec arbre standard de 20 mm S il est n cessaire d augmenter la distance entre l op rateur et...

Page 7: ...he arm use the optional extensions dimension with 50 mm shaft 107 mm with 80 mm shaft 137 mm Cote avec arbre standard de 20 mm S il est n cessaire d augmenter la distance entre l op rateur et le bras...

Page 8: ...n en sluiten in te stellen via KP CONTROLLER ppnings och st ngningshastighet st lls in med programmeringsenheten KP CONTROLLER BRACCIO ARTICOLATO B 0 mm ARTICULATED PUSH ARM B 0 mm BRAS ARTICUL POUSS...

Page 9: ...eid openen en sluiten in te stellen via KP CONTROLLER ppnings och st ngningshastighet st lls in med programmeringsenheten KP CONTROLLER BRACCIO A PATTINO L 430 mm CON MONTAGGIO OPERATORE SULL ARCHITRA...

Page 10: ...uiten in te stellen via KP CONTROLLER ppnings och st ngningshastighet st lls in med programmeringsenheten KP CONTROLLER BRACCIO A PATTINO L 330 mm CON MONTAGGIO OPERATORE SULL ARCHITRAVE B 160mm SLIDI...

Page 11: ...n en sluiten in te stellen via KP CONTROLLER ppnings och st ngningshastighet st lls in med programmeringsenheten KP CONTROLLER BRACCIO A PATTINO L 330 mm CON MONTAGGIO OPERATORE SULL ARCHITRAVE B 00mm...

Page 12: ...echnical documentation is compiled in accordance with part B of Annex VII of the above mentioned Machinery Directive The above identified partly completed machinery is also in compliance with the all...

Page 13: ...m 4 to 10 seconds Accessories power supply Electric lock power supply 24 V 1000mA max Operating modes by selector switch Open Automatic Manual or Night Pause time adjustable from 0 to 30 seconds Modes...

Page 14: ...0or 80 mm optional 3 APPLICATION LIMITS LEAF LENGTH mm MAX LEAF WEIGHT Kg ARTICULA TED PUSH ARM SLIDING ARM L 330 mm SLIDING ARM L 430 mm 700 367 286 750 320 249 800 281 219 850 249 194 900 222 173 95...

Page 15: ...emplates 4 2 INSTALLING THE TRANSMISSION ARMS It is always advisable to adjust the mechanical stops inside the opening closing operator so that they are occupied when the leaf reaches its mechanical s...

Page 16: ...programming unit optional 6 KP CONTROLLER locking key switch optional 7 Electric lock 24V max 0 5 A 8 Shunt box In case of operator on door installation make all electrical connections using a shunt b...

Page 17: ...is enabled the motor will not prevent manual opening 7 Not used 8 SCP Selectable Close Powe ring Additional force before closing NOTE With dip switch 9 set to OFF this function is never active Disable...

Page 18: ...rogress Slow flashing active fault LD3 Green LED for 5 V power supply 950 MPS BOARD TRIMMERS TR 1 Opening time adjustment 4 10 seconds TR 2 Closing time adjustment 4 10 seconds TR 3 Pause time adjustm...

Page 19: ...afety occupied Signals the status of input 14 LD8 Key command active Key command not active Signals the status of input 15 LD9 Fire prevention command active Fire prevention command not active Signals...

Page 20: ...pen it commands door closing the mode can be modified using the KP controller 13 Safety command during closing phase normally closed contact If open during closing it reverses the opening motion As lo...

Page 21: ...OPEN COMMAND n o EMERGENCY COMMAND n c SAFETY COMMAND DURING CLOSING n c STOP COMMAND DURING OPENING n c KEY COMMAND n o FIRE PREVENTION COMMAND n o CARD READER COMMAND GND GND 8 950 I 0 BOARD ELECTRI...

Page 22: ...70 1 XPB90 1 90 2 8 2 OPENING SAFETY SENSOR CONNECTION SET DIP 1 OF THE SENSOR TO ON 8 2 CLOSING SAFETY SENSOR CONNECTION Fig 9a Fig 9b IMPORTANT If this sensor is not present ter minal 13 must be con...

Page 23: ...ASSEMBLE THE SENSORS ON BOTH SIDES OF THE DOOR 2 ON THE CLOSING SAFETY SENSOR SET DIP 1 TO OFF 3 ON THE OPENING SAFETY SENSOR SET DIP 1 TO ON 4 CONNECT THE MASTER SENSOR TO THE SLAVE SENSOR VIA THE RE...

Page 24: ...950N 23 732708 Rev F J5 J4 950 I 0 J5 J4 ENGLISH ELECTROMAGNET 24V 8 4 ELECTROMAGNET COMMAND OUTPUT Fig 11 N C ELECTRIC LOCK 24 V 8 3 ELECTRICAL LOCK COMMAND OUTPUT N O Fig 10...

Page 25: ...ACT It closes when an automated system fault is active 8 5 DOOR STATUS OUTPUT Max contact capacity 0 5 A 24 V 8 6 BOARD FAULT OUTPUT Max contact capacity 0 5 A 24 V Fig 12 Fig 13 CARD READER INPUT N C...

Page 26: ...ator 4 Ensure that green LEDs LD1 and LD3 on the 950 MPS board are ON 5 Ensure that the status LEDs on the 950 I O board are in default status as shown in the table in figure 6 6 Perform a SET UP cycl...

Page 27: ...een two doors and the gong cannot be activated In a master and slave application all the sensor connections contacts test etc must be brought to the board set as master 12 LOW ENERGY dip switch 9 OFF...

Page 28: ...950N 27 732708 Rev F 530 107 121 mm ENGLISH 12 2 ASSEMBLINGTHEALUMINIUMHOUSING 4x TCI M5 x 10 FIXING SCREWS Fig 19...

Page 29: ...S Selection is done by pressing the keys located on the fixed section of the programmer the mode is identified by the lighting of the corresponding LED Note once the Night or Manual modes have been se...

Page 30: ...ac com au INDIA FAAC INDIA PVT LTD Noida Delhi India tel 91 120 3934100 4199 www faacindia com SWITZERLAND FAAC AG Altdorf Switzerland tel 41 41 8713440 www faac ch CHINA FAAC SHANGHAI Shanghai China...

Reviews: