background image

6

Radiocoder LED does not light up);

• Move Tx closer to make contact with the

Radiocoder and press the channel for which the
serial code is to be acquired (if the reading is
not done within about 15 sec. an 

Err

: message is

displayed; in such cases, press OK);

• If the reading has been done correctly, 

P8

appears on the display, then release the Tx key;

• Press OK, the procedure restarts proposing the

next Tx No.

P  9

TEACH SERIAL CODE TO TX

Transmits the serial code keyed in (6 alphanumeric
digits) to the Radiocoder for coding Tx.
• Enter the first two digits of the serial code

(alphanumeric values from 00 to FF);

• Press OK;
• Enter the second set of four digits of the serial

code
(alphanumeric values from 0000 to FFFF);

• Press OK: the serial code is transmitted by the

Radiocoder (the display shows four steady light
points and the Radiocoder LED lights up);

• Move the Tx closer to make contact with the

Radiocoder and press the channel on which the
serial code is to be stored, checking the double
flashing of the Tx LED (learning occurred);

• When operations are complete, press OK.

P  10

COPY MEMORY MODULE

Copy the MEX1 memory on MEX2 memory.

Â

the operation overwrites the MEX2 memory
contents.

Â

the copy includes the plant code, serial codes
and the password.

• When the function is confirmed, the contents of

MEX1 memory bank are copied on MEX2.

P  11

ENTER/CHANGE PASSWORD

Sets the password (4 alphanumeric digits).

Â

the password is stored in each memory bank
present.

• Enter the four digits of the new password

(alphanumeric values from 0000 to FFFF);

• Press OK.

P  12

DELETE DECODER

Completely deletes the memory banks present
(plant code, serial codes and password).

Â

the delete function is always possible, even
without knowing the password set, if any.

• When the function is confirmed, 

P12

 flashes;

• Press OK again to delete the Decoder: the

display shows four steady light points;

• at the same time, check to ensure that the

Decoder LED lights up for a few seconds;

• When the deletion is complete, the programmer

returns to stand-by.

SUGGESTIONS

• In the same plant, do not duplicate the Tx with

the same serial code;

• Do not store the same serial code in different

positions in the Decoder;

• The memory banks inserted in the Decoder must

have the same plant code and the same
password;

• If the functions protected by password are

accessed by initially keying in a password that is
different from that stored in the Decoder, an 

Err

:

message is displayed;

• For each plant, file the data relative to codes, Tx

No. and password.

P1

ENABLE Tx

Enter Tx No.(4 decimal digits from 0000 to 1999) + OK

P2

DISABLE Tx

Enter Tx No.(4 decimal digits from 0000 to 1999) + OK

P3

DELETE Tx

Enter Tx No.(4 decimal digits from 0000 to 1999) + OK

P4

ENTER PLANT CODE

Enter plant code (4+4 alphanumeric digits) + OK-->

(FROM KEYBOARD)

--> stores and transmits to Radiocoder

P5

ENTER PLANT CODE

Waiting reading of master Tx by Radiocoder

(FROM RADIOCODER)

P6

TEACH PLANT CODE

Enter plant code (4+4 alphanumeric digits) + OK-->

TO Tx

--> transmits to Radiocoder

P7

ENTER NEW Tx

Enter Tx No.(4 decimal digits from 0000 to 1999) + OK;

(FROM KEYBOARD)

Enter serial code (2+4 alphanumeric digits) + OK-->
--> stores and transmits to Radiocoder

P8

ENTER NEW TX

Enter Tx No.(4 decimal numbers from 0000 to 1999) + OK-->

(FROM RADIOCODER)

--> waiting reading of Tx by Radiocoder

P9

TEACH SERIAL CODE

Enter serial code (2+4 alphanumeric digits) + OK-->

TO Tx

--> transmits to Radiocoder

P10 COPY MEMORY

MEX1 is copied on MEX2

MODULE

P11 ENTER/CHANGE

Enter new password (4 alphanumeric digits) + OK

PASSWORD

P12 DELETE DECODER

P12

 flashes: press OK to delete decoder