FSW-OP, FSW-CL monitored
SAFE not monitored
FSW-OP, FSW-CL not monitored
SAFE monitored
FSW-OP, SAFE monitored
FSW-CL not monitored
FSW-CL, SAFE monitored
FSW-OP not monitored
FSW-OP, FSW-CL, SAFE monitored
Display
Function
Default
FINAL BRAKING:
When the gate reaches the opening or
closing limit-switch, a braking stroke can
be selected to ensure the leaf is stopped
immediately. If decelerations are selected,
braking starts when they finish.
At
value, braking is disabled.
Time can be adjusted from
to
in
0.01-second steps.
= Braking disabled
from
to
= Timed braking
PRE-FLASHING (5 s):
Activates the flashing lamp for 5 seconds
before start of movement.
= Disabled
= Only before opening
= Only before closing
= Before every movement
CLOSING PHOTOCELLS LOGIC:
Select the tripping mode of the closing pho-
tocells.
They operate for the closing movement only:
they stop movement and reverse it when they
are released, or they reverse it immediately.
= Reverse on release
= Reverse immediately to opening
Display
Function
Default
OPENING PHOTOCELLS LOGIC:
Select the tripping mode of the opening pho-
tocells.
They operate for the opening movement only:
they stop the movement and restart it when
they are released, or they reverse it immedia-
tely.
= Reverse immediately to closing
= Restart movement on release
ENCODER:
The encoder operates as an anti-crushing
device. If the gate hits an obstacle during
opening or closing, the encoder immediately
reverses the gate leaf movement for 2 secon-
ds. If the encoder operates again during the
2-seconds reversing time, the movement stops
(STOP) without commanding any reversing.
Adjust the sensitivity of the anti-crushing system,
by varying the parameter between
(maximum sensitivity) and
(minimum
sensitivity).
From
to
= Encoder active and sen-
sitivity adjustment
IMPORTANT: Do not set the sensitivity to
Pre-limit switch DECELERATION:
You can select gate deceleration before the
opening and closing limit-switches have been
tripped.
= Deceleration disabled
From
to
= Deceleration
enabled
Post-limit switch DECELERATION:
You can select gate deceleration after the
opening and closing limit-switches have been
tripped.
= Deceleration disabled
from
to
= Deceleration ena-
bled
FAIL SAFE:
This function allows to select wich safety inputs
will be monitored by the controller. it enables
a functional test of the photocells or safety ed-
ges before any gate movement. If the test fails
(device not present or not working are indica-
ted by the value
on the display), the gate
does not start moving.