4.9. J4 QUICK FIT CONNECTOR - FOR MINIDEC, DECODER AND RP
It is used for rapid connection of Minidec, Decoder and RP/RP2
Receivers.
If you are using an RP2 twin-channel receiver, you will be able to
directly command the automated system’s OPEN and CLOSE from
a twin-channel radio control.
If using a single-channel RP type receiver, only OPEN can be
commanded.
Fit the accessory with the components side directed toward the
board interior.
Insert and remove the boards ONLY after cutting
power.
4.6. J3, J5 RAPID CONNECTORS - FOR OPENING AND CLOSING
LIMIT-SWITCHES (FIG.2)
Quick-fit connector for connection of the opening (13) and closing
(J5) limit-switches.
4.7. J6 CONNECTOR - BEAM BREAKING SENSOR (FIG: 2)
Quick-fit connector for connecting the beam breaking sensor
(where present). If this sensor is absent, leave the supplied jumper
in place.
4.8. J11A,B,C CONNECTOR - QUICK-FIT CONNECTOR FOR
EXTERNAL LOOP DETECTOR (FIG.2)
Quick-fit connector for connecting the external loop-detector. For
adjustment and programming consult the relevant instruction.
An example of a 624BLD radio accessory connection
modification of the programming parameters is
immediately effective, whereas definitive memory-
storage occurs only on exiting programming and
returning to the view of the automation status. If you
cut power to the unit before returning to view the
status, all the modifications made will be lost.
You can return to viewing the status from any point
of programming at any level, by pressing keys
F
and
-
simultaneously.
To restore the programming default settings,
simultaneously press keys
+
,
-
and
F
and hold them
down for 5 seconds.
The following table indicates the sequence of functions accessible
in 1
ST
LEVEL PROGRAMMING:
5. PROGRAMMING
To program the operation of the automated system, you must access
the “
PROGRAMMING
” mode.
Programming is in two parts:
1
st
LEVEL and 2
nd
LEVEL
5.1. 1
ST
LEVEL PROGRAMMING
To access 1
ST
LEVEL PROGRAMMING, use push-button
F
:
• if you press it (and hold it down), the display shows the name
of the first function.
• if you release the push-button, the display shows the value of
the function, which can be changed with keys
+
and
-
.
• if you press
F
again (and hold it down), the display shows the
name of the next function, etc.
• when you reach the last function, press the
F
push-button
to exit programming, and the display resumes showing the
inputs status.
Fig. 9
1
ST
LEVEL PROGRAMMING
Display
Function
Default
LO
FUNCTION LOGICS:
A
Automatic
A1
Automatic 1
E
Semi-automatic
P
Parking
PA
Parking Automatic
Cn
Condo
CA
Condo Automatic
rb
Faac-City (traffic bollard logic)
C
Dead-man
r
Remote
Cu
Custom
E
PA
PAUSE TIME:
This operates only if an automatic logic
was selected. Can be adjusted from
0
to
59
in one second steps.
Next, the viewing changes in minutes and
tenths of a second (separated by a dot)
and time is adjusted in 10 second steps,
up to the maximum value of
4.1
minu-
tes.
E.g. if the display shows
2.5
, the pause
time will be 2 min and 50 sec.
20
FO
POWER:
adjusts motor power.
0 1
=
minimum power
50
=
maximum power
50
L 1
LOOP 1:
If this function is activated, the loop con-
nected to the Loop1 input will have the
OPEN function.
Y
= loop1 active
n o
= loop1 not active
Attention
: if the function is not activated, loop1
status will nevertheless be available on one of
the outputs, if appropriately set (see second le-
vel programming).
no