background image

6

1

5

8

2

6

4

3

9

7

TYPE OF OPERATOR

560 CBAC

560 SB

560 rap. CBACR

PUMP FLOW

RATE l/min.

1,0

1,0

1,5

ANGULAR

VELOCITY °/sec.

12,4

12,4

18,6

MAXIMUM

TORQUE Nm

320

320

230

HYDRAULIC LOCK

YES

NO

YES

  PANEL MAX

WIDTH m

1.50

2.00

0.5

3. TECHNICAL DATA

Fig. 1

AUTOMATED SYSTEM 560

1. AUTOMATED SYSTEM  560

The FAAC model 560 operator automates two-leaf folding doors
with one operator (fig. 2-4-6) or four-leaf doors (two-leaf units on
each side) with two operators (fig. 5).

2. GENERAL INFORMATION

The operator 560 consists of an hydraulic enbloc containing an
electric motor, a pump and a hydraulic jack. All these elements
are enclosed in an anodised aluminium housing of modern,
elegant design, which also acts as an oil tank.
It can be fitted on already installed doors or doors to be installed,
without any modifications to the structure.
The operator is also suitable for outdoor installation, providing an
ordinary plastic or steel sheet housing is provided to protect it
against direct contact with atmospheric agents.
Neither a chain nor a rack are necessary to transmit drive. Motion,
obtained via a rotating telescopic arm, is silent, smooth and fast.
The FAAC 560 automated system consists of a an hydraulic power
unit, an electronic control unit and installation accessories. Figure
1 shows the operator's overall dimensions.

4. ELECTRICAL CONNECTIONS

The fast version (CBACR) is recommended for doors with the width
of every single leaf of not less than 0.5 m.
The hydraulic lock is a special hydraulic function which guarantees
the door to lock when closing without having to use an electric
lock (maximum leaf dimensions: 1.5 m).
However, all models are supplied with a release device to facilitate
(in the SB type) or enable (in the CBAC and CBACR types) manual
opening or closing of the door.
In the SB version, an electric lock must be installed to ensure the
closing and/or opening position is maintained.

OPERATOR 560

Power supply (Vac 50-60Hz)

230 (+6 -10%)

Electric motor

single-phase induction 1450 rpm

Maximum absorbed power (W)

220

Absorbed current (A)

1

Thrust capacitor (µF)

8

Winding thermal protection (°C)

120

Maximum cycles/hour

80

Protection class

IP54

Operating ambient temperature [°C]

-20 / +55

Max weight of gearmotor (Kg)

12

Type of oil

FAAC HP OIL

Oil quantity (l)

1.2

IMPORTANT: arrange for the system to be earthed according to
current legal regulations.

Fig. 2

1. hydraulic operator FAAC model 560
2. electronic control unit
3. main switch
4. 6A fuse
5. junction box
6. indoor button-board
7. key operated push-button FAAC model T10 or T11
8. radio control receiver FAAC (3x0.5) and flashing lamp (FAAC

LAMP 2x1,5)

9. electric lock if necessary (for models SB only).

Reviews: