  3. LAYOUT AND COMPONENTS OF 45 MPS

Fig. 1

 

For connection  

of the photocells 

and safety  

devices, see p 

aragraph 4.1 (page 

3).

NB.: Capacitors are supplied with the operators.

Fig. 2

J4

J1

J3

F1

F2

1 2 3 4

9 10 11 12

5 6 7 8

1 2 3 4

PE N L

MAIN

1

2

4

5 6 7 8

COM OP

M1

COM OP

M2 CL

LAMP

9 10 11 12 13 14 15 16 17 18 19

OPEN

A

B STP CL OP

FSW

-

-

-

+24V

+

+

-TX

FSW

20 21

W.L.

LOCK

J5

J2

F

DL10

OP A

OP B

STOP

FSWOP

FSWCL

TOTALLY OPEN

OPEN LEAF 1

STOP

. WARNINGS

Important: Before attempting any work on the control board 
(connections, maintenance), always turn off power.

-  Install,  upstream  of  the  system,  a  differential  thermal  breaker 

with adequate tripping threshold.

-  Connect the earth cable to the appropriate terminal on the J3 

connector of the equipment (see fig.2).

-  Always  separate  power  cables  from  control  and  safety  cables 

(push-button,    receiver,  photocells,  etc.).  To  avoid  any  electric 
noise,  use  separate  sheaths  or  a  shielded  cable  (with  earthed 
shield).

  4. ELECTRIC CONNECTIONS

Led OP_A

 

TOTALLY OPEN LED

Led OP_B

 

LED: OPEN LEAF 1 / CLOSE

Led STOP

 

LED STOP

Led FSWCL

 

LED: CLOSING SAFETY DEVICES 

Led FSWOP

 

LED: OPENING SAFETY DEVICES

DL10

 

LED: TIME LEARNING SIGNALLING

J1

 

LOW VOLTAGE TERMINAL BOARD

J2

 

CONNECTOR FOR DECODER/MINIDEC/RP RECEIVER 

J3

 

230 VAC POWER SUPPLY TERMINAL BOARD

J4

 

MOTORS AND FLASHING LAMP CONNECTION TERMINAL BOARD

J5

 

INDICATOR-LIGHT AND ELECTRIC LOCK TERMINAL BOARD

F1

 

MOTORS AND TRANSFORMER PRIMARY WINDING FUSE (F 5A)

F2

 

LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA) 

TIME LEARNING  PUSH-BUTTON

DS1

 

1ST GROUP OF MICROSWITCH PROGRAMMING

DS2

 

2ND GROUP OF MICROSWITCH PROGRAMMING

F

F1

F2

J1

J2

J3

J4

J5

Led

DL10

DS1

DS2

  . TECHNICAL SPECIFICATIONS

Power supply 

230 V~ ( +6%  -10%) - 50 Hz

Absorbed power 

10 W

Motor max. load 

800 W

Accessories max. load 

0,5 A

Electric lock max. load 

15 VA

Operating ambient temperature        

-20 °C +55 °C

Protection fuses 

 2 (see fig. 1)

Function logics                       

Automatic / Semi-automatic / "Stepped" Safety  device / Semi-automatic B/ 

 

Dead-man C / "Stepped" semi automatic 

Opening/closing time 

Programmable (from 0 to 120 s)

Pause time 

0, 10, 20, 30, 60, 120 s

Closing leaf delay 

0, 5, 10, 20 s

Opening leaf delay               

2 s (Can be disabled with the dip-switch)

Thrust force 

Dip-switch adjustable on 8 levels for each motor

Terminal board inputs  

Open / Open free leaf / Stop / Opening safety devices /  

 

Closing safety devices / Power Earth

Terminal board outputs 

Flashing lamp - Motors - 24 Vdc accessories  power supply - 24 Vdc  

 

indicator-light - Fail safe - 12 Vac electric lock power supply

Rapid connector

  

To connect Minidec, Decoder or RP cards

Selectable functions  

Logics and pause times - Thrust force - Opening and closing leaf delay  

 

- Reversing stroke -Fail safe - Closing safety devices logic - Pre-flashing

Programming key  

work time learning

BL

U

BL

U

CONTROL BOARD 452 MPS

Summary of Contents for 452 MPS

Page 1: ...452 MPS...

Page 2: ...equate level of safety the Standards mentioned above must be observed in addition to national legal regulations 11 Before attempting any job on the system cut out electrical power 12 The mains power s...

Page 3: ...MINAL BOARD J2 CONNECTOR FOR DECODER MINIDEC RP RECEIVER J3 230 VAC POWER SUPPLY TERMINAL BOARD J4 MOTORSANDFLASHINGLAMPCONNECTION TERMINAL BOARD J5 INDICATOR LIGHT AND ELECTRIC LOCK TERMINAL BOARD F1...

Page 4: ...against the risk of impact and crushing Closing safety devices they operate only during the gate closing movement and therefore they are suitable for protecting the closing area against the risk of i...

Page 5: ...photocells and a pair of closing photocells Fig 11 Connection of two pairs of closing photocells Fig 10 Fig 8 Fig 9 Connection of 1 pair of closing photocells Fig 12 Fig 13 Connection of 2 N C contact...

Page 6: ...ing closing in the A SP E EP logics the safety devices reverse the movement of the gate leaves or stop and reverse the movement when they are re leased see programming of microswitch DS2 SW2 During th...

Page 7: ...versing stroke pushes the leaves to close for a few moments before opening the gate thus facilitating release of the electric lock The equipment is endowed with two groups of microswitch es DS1 fig 18...

Page 8: ...on pause like indicator light Time learning flashes rapidly 6 3 LEARNING OF OPERATING TIMES The procedure has ended and the gate is ready to operate Next pulse closes leaves and they stop on automatic...

Page 9: ...N on PAUSE Stops operation Stops operation No effect Closes after 5 OPEN disabled lighted AT CLOSING Re opens the leaves immediately Re opens the leaf immediately No effect saves OPEN see paragraph 5...

Page 10: ...o effect OPEN B disabled W L lighted flashing lighted lighted No effect OPEN A disabled OP CLOS SAFETY DEVICE CLOSING SAFETY DEVICES OPENING SAFETY DEVICES STOP OPEN B Stops operation OPEN A B disable...

Page 11: ...n in vorliegendem Handbuch sind unverbindlich FAAC beh lt sich das Recht vor ohne die wesentlichen Eigenschaften dieses Ger tes zu ver ndern und ohne Verbindlichkeiten in Bezug auf die Neufassung der...

Reviews: