CE DECLARATION OF CONFORMITY

Manufacturer: 

FAAC S.p.A.

Address:

 

Via Benini, 1  - 40069  Zola Predosa BOLOGNA - ITALY

Declares that: 

452 MPS control board,

 
 

• conforms to the essential safety requirements of the following directives:

 

2006/95/EC Low Voltage Directive 

 

  2004/108/EC Electromagnetic Compatibility Directive 

 

Additional note:

 

This product underwent tests in a typical uniform configuration  

 

(all products manufactured by FAAC S.p.A.).

 

Bologna, 01 September 2008

 

   

 

 

 

 

The Managing Director

 

   

 

 

 

 

A. Marcellan

 

1)  ATTENTION! To ensure the safety of people, it is important that you read 

all the following instructions. Incorrect installation or  incorrect use of 

the product  could  cause  serious harm   to people.

  2)  Carefully read the instructions before beginning to install the product.
  3)  Do not  leave packing materials (plastic, polystyrene, etc.)   within  reach 

of  children as  such materials  are  potential  sources  of  danger.

  4)  Store these instructions for  future reference.
  5)  This product was designed and built strictly for the use indicated in this 

documentation. Any other use, not expressly indicated here, could 

compromise the good condition/operation of the product and/or be 

a source of danger.

  6)  FAAC declines all liability caused by improper use or use other than 

that for which the automated system was intended.

  7)  Do not install the equipment in an explosive atmosphere: the presence 

of  inflammable gas or fumes is a serious danger to safety.

  8)  The mechanical parts must conform to the provisions of Standards EN 

12604 and EN 12605.

 

  For  non-EU  countries,  to  obtain  an  adequate  level  of  safety,  the 

Standards mentioned above must be observed, in addition to national 

legal regulations.

  9)  FAAC  is  not  responsible  for  failure  to  observe  Good  Technique  in 

the construction of the closing elements to be motorised, or for any 

deformation that may occur during use.

 10)  The installation must conform to Standards EN 12453 and EN 12445.

 

    For  non-EU  countries,  to  obtain  an  adequate  level  of  safety,  the 

Standards mentioned above must be observed, in addition to national 

legal regulations.

 11)  Before attempting any job on the system, cut out electrical power .
 12)  The mains power  supply of the automated system must be fitted with 

an all-pole  switch with contact opening distance of 3mm or greater. Use 

of a 6A thermal breaker with all-pole circuit break is recommended.

 13)  Make sure that a differential switch with threshold of 0.03 A is fitted 

upstream of the system.

 14)  Make sure that the earthing system is perfectly constructed, and connect 

metal parts of  the means of  the closure to it. 

 15)  The  safety  devices  (EN  12978  standard)    protect  any  danger  areas 

against 

mechanical movement Risks

, such as crushing, dragging, and 

shearing.

 16)  Use of at least one indicator-light (e.g. FAACLIGHT ) is recommended 

for every system, as well as a warning sign adequately secured to the 

frame structure, in addition to the devices mentioned at point “15”.

 17)  FAAC declines all liability as concerns safety and efficient operation of 

the automated system, if system components not produced by FAAC 

are used.

18)   For maintenance, strictly use original parts by FAAC.
 19)  Do  not  in  any  way  modify  the  components  of  the  automated 

system.

 20)  The installer shall supply all information concerning manual operation 

of the system in case of an emergency, and shall hand over to the user 

the warnings handbook supplied with the product.

 21)  Do  not  allow  children  or  adults  to  stay  near  the  product  while  it  is 

operating.

 22)  Keep remote controls or other pulse generators away from children, to 

prevent the automated system from being activated involuntarily.

 23)  Transit is permitted only when the automated system is idle.
 24)  The user must not attempt any kind of repair or direct action whatever 

and contact qualified personnel only.

 25)  Maintenance: check at least every 6 months the efficiency of the system, 

particularly the efficiency of the safety devices (including, where foreseen, 
the operator thrust force) and of the release devices.

 

 26)  Anything not expressly specified in these instructions is not permitted.

WARNINGS FOR THE INSTALLER

GENERAL SAFETY OBLIGATIONS

Summary of Contents for 452 MPS

Page 1: ...452 MPS...

Page 2: ...equate level of safety the Standards mentioned above must be observed in addition to national legal regulations 11 Before attempting any job on the system cut out electrical power 12 The mains power s...

Page 3: ...MINAL BOARD J2 CONNECTOR FOR DECODER MINIDEC RP RECEIVER J3 230 VAC POWER SUPPLY TERMINAL BOARD J4 MOTORSANDFLASHINGLAMPCONNECTION TERMINAL BOARD J5 INDICATOR LIGHT AND ELECTRIC LOCK TERMINAL BOARD F1...

Page 4: ...against the risk of impact and crushing Closing safety devices they operate only during the gate closing movement and therefore they are suitable for protecting the closing area against the risk of i...

Page 5: ...photocells and a pair of closing photocells Fig 11 Connection of two pairs of closing photocells Fig 10 Fig 8 Fig 9 Connection of 1 pair of closing photocells Fig 12 Fig 13 Connection of 2 N C contact...

Page 6: ...ing closing in the A SP E EP logics the safety devices reverse the movement of the gate leaves or stop and reverse the movement when they are re leased see programming of microswitch DS2 SW2 During th...

Page 7: ...versing stroke pushes the leaves to close for a few moments before opening the gate thus facilitating release of the electric lock The equipment is endowed with two groups of microswitch es DS1 fig 18...

Page 8: ...on pause like indicator light Time learning flashes rapidly 6 3 LEARNING OF OPERATING TIMES The procedure has ended and the gate is ready to operate Next pulse closes leaves and they stop on automatic...

Page 9: ...N on PAUSE Stops operation Stops operation No effect Closes after 5 OPEN disabled lighted AT CLOSING Re opens the leaves immediately Re opens the leaf immediately No effect saves OPEN see paragraph 5...

Page 10: ...o effect OPEN B disabled W L lighted flashing lighted lighted No effect OPEN A disabled OP CLOS SAFETY DEVICE CLOSING SAFETY DEVICES OPENING SAFETY DEVICES STOP OPEN B Stops operation OPEN A B disable...

Page 11: ...n in vorliegendem Handbuch sind unverbindlich FAAC beh lt sich das Recht vor ohne die wesentlichen Eigenschaften dieses Ger tes zu ver ndern und ohne Verbindlichkeiten in Bezug auf die Neufassung der...

Reviews: