1. PROGRAMMING THE MICROSWITCHES

Automation programming is carried out by the microswitches
(fig. 1 - ref. 9) as shown in the diagram below.

4)

Switch on the power.

5)

Send an OPEN signal to input A (fig. 2) and check that the
leaf opens.

If the gate closes, invert the motor wires on the control unit
(brown and black wires).

2.2. OPERATION TIME ADJUSTMENT

Opening/closing times are set by the OP/CL trimmer on the
control unit (fig. 1 - ref.7).
To reduce operation time, adjust the trimmer anticlockwise
To increase operation time, adjust the trimmer clockwise.
Maximum operation time is 120 seconds.
For 90° opening the approximate opening/closing time is 18
seconds.
For optimal system efficiency set the opening/closing time so
that the electric motor remains activated for a few seconds
after the leaf has reached the mechanical travel stop.

2.3. CLOSING LEAF DELAY ADJUSTMENT

In the case of overlapping leaves, it is possible to delay closing
of the leaf driven by motor M1 (see fig. 2) to ensure correct
closure of the gate.
Set the delay by the LEAF DELAY trimmer on the 450 MPS control
unit (fig. 1 - ref. 8).
To reduce delay time, adjust the trimmer anticlockwise.
To increase delay time, adjust the trimmer clockwise.
Maximum delay time is 28 seconds. If the operation time is
shorter, the delay time is reduced automatically.

2.4. SETTING PAUSE TIME

When A or S logics are selected, the leaf momentary stop time
can be set using the PAUSE trimmer (fig. 1 ref. 6).
Turn the trimmer clockwise to increase the time.
Turn the trimmer anticlockwise to reduce the time.
The maximum pause time is 240 sec.

2.5. ANTI-CRUSHING SYSTEM ADJUSTMENT

The 450 MPS control unit has been designed for use on both
electromechanical and hydraulic operators.
When the 450 MPS card is used on electromechanical operators,
the torque control device must be set by turning the TORQUE
trimmer (fig. 1 ref. 5).
To reduce torque, adjust the trimmer anticlockwise.
To increase torque, adjust the trimmer clockwise.
In any event, FAAC advises not to exceed a torque of 15 Kg
measured on the outer edge of the leaf.
To ensure precise torque adjustment use a linear dynamometer.
When the 450 MPS card is used on hydraulic operators, the
torque control device must be set to the maximum value by
turning the TORQUE trimmer clockwise.
This device is already present inside the operator hydraulic
circuit (BY-PASS valves).

1.1. OPERATION LOGICS

There are seven operating logics available:

A : “AUTOMATIC ”

E : “SEMI-AUTOMATIC”

S : “SAFETY”

EP : “SEMI-AUTOMATIC STEP-BY-STEP”

B : “DEAD-MAN BUTTON” C : “DEAD-MAN BUTTON”
B/C : “DEAD-MAN BUTTON” AD :“AUTOMATIC TIMER”

Operation of the different logics is described in tables 3/a-b-c-d-e-f-g-h.

1.2. REVERSING STROKE FOR ELECTRIC LOCK

This function is to be activated only if the electric lock is
installed.

1.3. SAFETIES ON CLOSING

This function serves to select the operating mode for the closing
safeties:

- OFF: immediate reverse of movement during gate closure
- ON: movement is stopped during closing and reversed on

opening when the safety is disengaged.

2. START-UP

1)

Program the 450 MPS electronic control unit according to
specific requirements as shown in fig. 14.

2)

Check led status as shown in table.

LED functions

LEDS

ON

OFF

DL 1 (OPEN INPUT A)

Command active

Command not active

DL 2 (OPEN INPUT B)

Command active

Command not active

DL 3 (STOP)

Command not active

Command active

DL 4 (FTSW OPEN)

Safeties disengaged

Safeties engaged

DL 5 (FTSW CLOSE)

Safeties disengaged

Safeties engaged

N.B.:

 the bold text indicates led status with gate idle.

2.1. DIRECTION OF ROTATION

1)

Switch off the power.

2)

Manually move the gate to halfway.

3)

Lock the operators.

Fig. 15

A

S

E

EP

SW1

OFF

ON

OFF

ON

SW2

OFF

OFF

ON

ON

SW5

OFF

ON

SW4

ON

OFF

1

2

3

4

5

B

C

ON

OFF

OFF

ON

SW3

OFF

OFF

OFF

OFF

ON

ON

B/C

ON

OFF

ON

AD

ON

ON

OFF

OPERATING LOGICS

INVERTS MOVEMENT
IMMEDIATELY

STOPS AND INVERTS
MOVEMENT ON
DISENGAGEMENT

SAFETIES ON CLOSING

REVERSING STROKE FOR

ELECTRIC LOCK

ACTIVATED

NOT ACTIVATED

Fig. 14

Enable

Disable

Disable

Enable

FAIL-SAFE

LEAF DELAY

Summary of Contents for 450 MPS Control Panel

Page 1: ...Altpapier pour la nature papier recycl 100 for nature recycled paper 100 per la natura carta riciclata 100 para la naturaleza 100 papel reciclado C ERME T A Z I E N D A C E R TIF I C A T A UNI EN ISO...

Page 2: ...shall be provided for the installation with an opening distance of the contacts of 3 mm or more Alternatively use a 6A thermomagnetic breaker with multi pole switching 13 Ensure that there is a differ...

Page 3: ...hotocells A A A B B Closingphotocells OPEN TOT OPEN IND STOP Forthesafetyandfail safedevices seethe Safetydevices section N B The capacitors are provided with the operators Fig 2 Warning the max acces...

Page 4: ...are disengaged see microswitch SW4 settings They do not engage during the opening cycle In B C and B C logics they interrupt movement during the closing cycle They do not engage during the opening cyc...

Page 5: ...X TX 14 15 24 23 16 12 13 30Vcc OP CL FSW FSWTX Fig 4 A Fig 5 A Fig 6 A Fig 7 A Fig 8 A Fig 9 A Application examples The following are the commonly used connection arrangements disable fail safe No sa...

Page 6: ...system f PAUSE trimmer pause time adjusting trimmer A S AD logics Pause time is adjustable from 0 to 240 seconds g OP CL trimmer Opening Closing time adjusting trimmer Time is adjustable from 0 to 12...

Page 7: ...djust the trimmer anticlockwise To increase torque adjust the trimmer clockwise In any event FAAC advises not to exceed a torque of 15 Kg measured on the outer edge of the leaf Toensureprecisetorquead...

Page 8: ...leaves OPEN No effect OPEN inhibited No effect OPEN inhibited Stops LOGICS EP PULSES GATE STATUS OPEN A No effect if the gate must open inhibits OPEN No effect if gate must close inhibits OPEN W L on...

Page 9: ...N A B inhibited No effect OPEN A inhibited No effect OPENING PULSE HOLD TO RUN CONTROL No effect OPEN A B inhibited Interrupts operation OPEN B inhibited Interrupts operation OPEN A B inhibited No eff...

Page 10: ...ner al d a la presente publicaci n todas las modificaciones que considere oportunas para el perfeccionamiento t cnico o para cualquier otro tipo de exigencia de car cter constructivo o comercial FAAC...

Reviews: