background image

3

A

B

C

4

0

 /

  

6

0

α

°

X

Fig. 3

Fig. 6

Fig. 4

Fig. 5

3. ELECTRICAL  EQUIPMENT  (standards  system)

4. INSTALLATION  OF  AUTOMATION

4.1.

PRELIMINARY CHECKS

To ensure safety and an efficient automation, make sure the
following requirements are met:

The  gate  structure  must  be  suitable  for  automation.  In
particular, make sure it is sufficiently sturdy and rigid, and
that its dimensions are in line with those indicated in the
technical specifications.

Make sure that the leaves move properly and uniformly,
without any irregular friction during their entire travel.

Check if hinges are in good condition.

Make sure the travel limit mechanical stops are present.

We  advise  you  to  carry  out  any  metalwork  jobs  before
installing the automation.

4.2.

INSTALLATION DIMENSIONS

Establish the installation position of the operator  by consulting Fig.
4-5-6.

4.2.1. RECOMMENDED DIMENSIONS FOR INWARD OPENING

4.2.2. RECOMMENDED DIMENSIONS FOR OUTWARD OPENING

1)

Operators mod. 390

2)

Photocells

3)

Electronic equipment

4)

Key-operated push-button

5)

Radio receiver

6)

Flashlight

Notes: 1)

 To lay electrical cables, use adequate rigid and/

or flexible tubes.

2)

Always separate low voltage accessories from

those  operating  at  230V~.  To  avoid  any
interference, always use separate sheaths.

•measurements in mm

•measurements in mm

•measurements in mm

    A

B

C (max)

 60÷110

110÷130

   730

    90°

110÷160

110÷130

   720

    90°

160÷210

110÷130

   710

    90°

210÷260

110÷130

   700

    90°

260÷310

110÷130

   690

    90°

310÷360

110÷130

   670

    90°

 60÷110

190÷210

   650

    120°

110÷160

230÷250

   600

    120°

160÷210

290÷310

   540

    120°

210÷260

310÷330

   510

    120°

α

α

α

α

α

    A

B

C (max)

 60÷110

110÷130

   430

    90°

110÷160

110÷130

   380

    90°

160÷210

110÷130

   330

    90°

210÷260

110÷130

   280

    90°

260÷310

110÷130

   240

    90°

α

α

α

α

α

C

B

A

α

°

4

0

 /

 6

0

~

 2

0

0

~

 4

1

Notes:

As for 120° openings the curved arm must be fixed

to the hole marked with the letter 

X

Reviews: